Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007
![]() |
Han, Hwa-Taik
(School of Mechanical and Automotive Engineering, Kookmin University)
Shin, Dong-Sin (Department of Mechanical System Design Engineering, Hongik University) Choi, Chang-Ho (Department of Architectural Engineering, Kwangwoon University) Lee, Dae-Young (Korea Institute of Science and Technology) Kim, Seo-Young (Korea Institute of Science and Technology) Kwon, Yong-Il (Department of Building Mechanical Engineering, Shinheung College) |
1 | Shin, J. K., 2007, Prediction of Stratified Turbulent Channel Flows with an Second Moment Model Using the Elliptic Equations, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 831-841 과학기술학회마을 |
2 | Hwang, J. and Kang, B. H., 2007, Effects of Thermoelectric Module Arrangementon the Performance of a Thermoelectric Air- Cooling System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 162- 168 과학기술학회마을 |
3 | Won, S. P., 2007, Performance Analysis of Integral Receiver/Dryer Condenser for Auto mobile, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 245-252 과학기술학회마을 |
4 | Kang, S. H., Byun, J. S. and Lee, J., 2007, Ventilation Analysis according to Jet Fan Location in Long Tunnel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 386-393 과학기술학회마을 |
5 | Youn, Y., Jeon, H. H. and Lee, K. B., 2007, Numerical Simulation of the Thermal Environment Inside an Opened Tomb, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 43-50 과학기술학회마을 |
6 | Choi, J. M., Cho, S. W., Park, C. S., Park, M. Y. and Lee, K. H., 2007, A Study on the Simulation Evaluation of IAQ at the Process of Building Construction, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 60-67 과학기술학회마을 |
7 | Kim, N. H., Shin, T. R. and Han, S. P., 2007, Heat Transfer Characteristics of Individual Rows for Fin-and-Tube Heat Exchangers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 149-155 과학기술학회마을 |
8 | Kim, H. C., Sohn, J. Y. and Park, H. J., 2007, Experimental Study of the Blowoff Flame Phenomena Due to Changes of Balcony Length, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 235-244 과학기술학회마을 |
9 | Park, S. I., 2007, A Study on Prediction Model of Flow and Heat Transfer in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 263-268 과학기술학회마을 |
10 | Hur, J., Lee, S. J., Sung, J. Y., Lee, M. H. and Yoon, J. D., 2007, Performance Test of Pressure and Flow Rate in a Hot-Water Heating System with 3-Way Valves for Flow Bypass, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 269-274 과학기술학회마을 |
11 | Kum, J. S., Kim, D. G. and Park, J. I., 2007, Evaluation of Thermal Comfort during Sleeping in Summer, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 307-312 과학기술학회마을 |
12 | Sohn, D. Y., Lim, J. H., Choi, Y. H. and Park, J. H., 2007, A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 321-327 과학기술학회마을 |
13 | Yoo, S. Y., Lee, J. M., Han, K. H. and Han, S. H., 2007, A Study on Prediction of Temperature and Humidity for Estimation of Cooling Load, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 394-402 과학기술학회마을 |
14 | Son, Y. S., Shin, J. Y. and Lee, S. R., 2007, Heat Transfer Characteristics depending on the Length of a Channel with Pin-Fin Array, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 418-426 과학기술학회마을 |
15 | Kim, G. T., Cheong, S. I., Joo, H. Y., Ahn, U. C. and Lee, J. K., 2007, Economic Analysis of Heat Pump System through Actual Operation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 470-475 과학기술학회마을 |
16 | Ahn, Y. C., Jung, S. H., Hwang, Y. J., Lee, C. G., Kim, D. H., Jung, S. I. and Lee, J. K., 2007, Prediction of Characteristics for the Air-side Particulate Fouling in Finned- Tube Heat Exchangers of Air Conditioners used in the Field, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 563-568 과학기술학회마을 |
17 | You, H. J., Jung, E. J. and Kim, J. S., 2007, A Study on the Prediction of Building Equipment Noise Generates at Machine Room, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 476-484 과학기술학회마을 |
18 | Chung, J. D., Lee, D. Y. and Yoon, S. M., 2007, Optimization of the Area Ratio of Regeneration to Dehumidification and Rotor Speed on the Condition of Low Regeneration Temperature, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 521-528 과학기술학회마을 |
19 | Shim, Y. B., Park, K. J., Jung, D. and Kim, J. S., 2007, Condensation Heat Transfer Coefficients of R245fa on a Plain Tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 555-562 과학기술학회마을 |
20 | Chung, J. D., Lee, D. Y. and Yoon, S. M., 2007, Effect of Desiccant and Channel Geometrics on the Performance of Desiccant Rotor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 569-576 과학기술학회마을 |
21 | Byun, J., Kang, S. H., Kim, J. and Lee, J., 2007, Ventilation Analysis According to Jet Fan Location in Curved Long Road Tunnel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 669-678 과학기술학회마을 |
22 | Hur, J., Lee, S. J., Sung, J. Y. and Lee, M. H., 2007, Fluid Dynamic Performance in a Hot-Water Heating System with a Variable- Flow-Rate Balancing Valve, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 577-584 과학기술학회마을 |
23 | Cho, H., Baek, C., Ryu, C. and Kim, Y., 2007, Simulation Study on the Performance Characteristics of a CO2 Cooling System with an Expander, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 630-639 과학기술학회마을 |
24 | Byun, J. S., Lim, H. J., Kang, S. H. and Lee, J., 2007, Analysis of Smoke Control According to Jet Fan Location in Straight Long Tunnel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 662-668 과학기술학회마을 |
25 | Kwon, S. H., Bae, N. R. and Chun, C. Y., 2007, Effect of Electric Charge on the Operating Behavior of Air-conditioner and Thermal Comfort in Summer Season, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 703-709 과학기술학회마을 |
26 | Park, K. S., Kang, B. H., Park, K. K. and Kim, S, 2007, Correlations of Oil Concentration Prediction during In-line Flow of CO2/Oil Mixtures, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 718-725 과학기술학회마을 |
27 | Kim, S. H., Lee, S. and Kim, D. G., 2007, A Study of Thermal Comfort by Winter Temperature Humidity Change, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 803-810 과학기술학회마을 |
28 | Park, K. J., Woo, S. G. and Jung, D., 2007, Lower Flammability Limits of Flammable Refrigerants According to ASTM E681-04 Standard, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 726-734 과학기술학회마을 |
29 | Kim, M. J., Kim, J. H., Yun, J. H., Park, I. H. and Lee, K. C., 2007, The Experimental Study on the Heat Transfer Characteristics of Ice Slurry Generator Using Air Cylinder, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 743-750 과학기술학회마을 |
30 | Byun, K. H. and Smith, T. F., 2007, The Experimental Study of Radiant Cooling Test System under Different Covers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 797-802 과학기술학회마을 |
31 | Kim, K. C., Park, M. H., Jun, K. Y. and Lim, J. H., 2007, A Study for Optimal Design of the AIG to Improve the Performance of DeNOx Facilities Installed in Combined Cycle Plant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 811-820 과학기술학회마을 |
32 | Chung, M. H., Jung, S. M., Kim, M. Y., Kim, G. W. and Park, J. C., 2007, A Field Survey of Indoor Air Environment of Schools, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 865-873 과학기술학회마을 |
33 | Hang, H. H., Kim, C. N. and Jung, J., 2007, Effect of Inlet and Outlet Position on the Pumping Characteristics of a Diffuser/Nozzle Based Piezoelectric Micropumps, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 411-417 과학기술학회마을 |
34 | Park, H., Lee, J. and Rho, B., 2007, Effects of a Guide Fin Blade on the Flow Characteristicsin a Ventilating Axial Fan, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 874-882 과학기술학회마을 |
35 | Kim, M. J., Yu, J. S., Lim, J. K. and Choe, S. Y., 2007, A Study on the Measuring Method of Ice Slurry Viscosity Using the Falling Sphere Viscometer, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 593-598 과학기술학회마을 |
36 | Kim, W. Y., Ahn, J. M., Kim, H. J. and Cho, S. O., 2007, Solubility Consideration in Performance Analysis of a CO2 Twin Rotary Compressor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 842-849 과학기술학회마을 |
37 | Shin, Y., Cho, S., Tae, C. S. and Jang, C. Y., 2007, A Dynamic Simulation Model of Electronic-Expansion-Valve-Controlled Evaporators, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 183-190 과학기술학회마을 |
38 | Kim, B. H., 2007, A Study on the Thermal Conductivity of Carbon-Nanotube Nanofluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 275-284 과학기술학회마을 |
39 | Youm, M. Q., Jeong, J. and Kim, C. N., 2007, A Numerical Analysis of the Abatement VOC in a Photocatalytic Micro-reactor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 285-290 과학기술학회마을 |
40 | Koh, D. Y. and Lee, K. S., 2007, A Study of Optimum Insulation Conditions of a HTS Power Cable Cryostat, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 333-338 과학기술학회마을 |
41 | Kim, H. K., Jeong, S., Her, N., Lim, T. and Park, Y., 2007, Numerical Analysis of the Melting Process of Ice Using Plate Heaters with Constant Heat Flux, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 434-440 과학기술학회마을 |
42 | Hong, J. K. and Choi, S. G., 2007, A Study on the Diffusion and Removal of Airborne Microorganism Pollution in Multistoried Apartment by the Multi-Zone Simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 291-298 과학기술학회마을 |
43 | Moon, J. H., Moon, S. J. and Lee, J. H., 2007, Thermal Reliability Analysis of the Bearing Units in a Centrifugal Pump, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 313-320 과학기술학회마을 |
44 | Kim, B. H. and Na, S. Y., 2007, A Case Study on Green Remodeling of Water System in Jeju Airport, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 464-469 과학기술학회마을 |
45 | Kim, G. and Kim, J. T., 2007, Economic Feasibility Analysis on the Benefit of Daylighting Incorporation Devices Under Clear Skies, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 491-499 과학기술학회마을 |
46 | Kang, H. G. and Lee, J. H., 2007, The Freezing Process of the Water Supply Pipe in an Exterior Wall, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 782-788 과학기술학회마을 |
47 | Sung, K. C. and Chang, H. J., 2007, Field Studies on the Improvement of Indoor Air Quality by Ventilator in Apartment Houses, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 202-212 과학기술학회마을 |
48 | Kim, Y. H., Lee, Y., Lee, K. J., Kim, U., Choi, J. M. and Ko, J. M., 2007, Numerical Simulation on Cooling Plates in a Fuel Cell, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 86-93 과학기술학회마을 |
49 | Kwak, K. M., Bai, C. H., Kim, J. Y. and Chu, E. S., 2007, A Study on Improvement of Performance for Perforated Type Total HEX Element, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 529-536 과학기술학회마을 |
50 | Lee. T. G., Moon, J. H., Hur, J. H. and Lee, J. H., 2007, Improvement of the Ventilation Equipment in a Waste Bunker For a Municipal Waste Incinerator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 51-59 과학기술학회마을 |
51 | Seo, J. M., Choi, Y. J., Song, D., Chang, H. J. and Kim, S. J., 2007, Effect of the Balcony Space on Thermal Environment and Heating/Cooling Load in an Apartment House, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 364-371 과학기술학회마을 |
52 | Han, H. and Shin, M. W., 2007, A Study on Heat Recovery Characteristics of Porous Media According to Periodic Oscillating Flows, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 175-182 과학기술학회마을 |
53 | Jeon, J., Kim, Y., Choi, J. M., Hyun, D. S. and Yun R., 2007, Performance Characteristics of Liquid-Cooling Heat Exchangers with MPCM Slurry Designed for Telecommunication Equipment, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 710-717 과학기술학회마을 |
54 | Kim, H. K., Jeong, S., Hur, N., Lim, T. and Park, Y. S., 2007, Numerical Analysis of Melting Process in a Water Tank for Fuel-cell Vehicles, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 585-592 과학기술학회마을 |
55 | Baek, I. C., Park, K. J., Shim, Y. B. and Jung, D., 2007, Performance of Alternative Refrigerants for R12 and R134a in Automobile Air-Conditioners, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 403-410 과학기술학회마을 |
56 | Jung, H. W., Pack, J. H., Kim, Y., Kang, C., ang Hong, H., 2007, A Real Time Measurement of Ice Concentration of Ice Slurry in Pipe, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 599-606 과학기술학회마을 |
57 | Kang, H, Lee, S., Joo, Y., Chung, H., Kim, Y. and Choi, J., 2007, Experimental Study on the Performance Characteristics of a Simultaneous Heating and Cooling Heat Pump System at Each Operating Mode, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 679-686 과학기술학회마을 |
58 | Chung, J. D., 2007, Study on the Melting Point of Ar by Molecular Dynamic Simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 883-888 과학기술학회마을 |
59 | Chang, K. S. and Phan, T. H., 2007, Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 1-9 과학기술학회마을 |
60 | No, S. T., Kim, K. S. and Chung, J. S., 2007, A Study on the Development of High-rise Curtain Wall Thermal Analysis Program, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 10-18 과학기술학회마을 |
61 | Her, N., Lee, M. and Yang, S., 2007, Numerical Simulation of Ventilation in the Storage Hall of Tripitaka Koreana at Haein Temple in Case of Building Rearrangement, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 379-385 과학기술학회마을 |
62 | Lee, D. Y., Lee, G. and Lee, M. S., 2007, A Proposal for New Definition of Performance Indices of a Desiccant Rotor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 537-544 과학기술학회마을 |
63 | Park, J. Y., Jun, H. H., Jun, Y. D. and, Lee, K. B., 2007, Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 228-234 과학기술학회마을 |
64 | Jeong, E. S., 2007, Heat Transfer Coefficient and Shear Factor Subjected to Both Oscillating Flow and Oscillating Pressure in Pulse Tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 220-227 과학기술학회마을 |
65 | Chung, D. Y., Peck, J. H., Kang, C. and Hong, H., 2007, The Effect of Ice Adhesion according to Functional Group and Chemical Structure of Additive, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 8, pp. 607-614 과학기술학회마을 |
66 | Kang, H. K., Ahn, S. W. and Putra, A. B. K., 2007, Experimental and Numerical Analysis for Effects of Two Inclined Baffles on Heat Transfer Augmentation in a Rectangular Duct, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 751-760 과학기술학회마을 |
67 | Kang, H. G. and Lee, J. H., 2007, Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 695-702 과학기술학회마을 |
68 | Kim, W. K., Han, S. H. and Choi, Y. D., 2007, Velocity Measurement Technique in a Narrow Passage by Hot-wire Anemometer, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 191-201 과학기술학회마을 |
69 | Yoo, H., Jhung, J. H., Moon, J. H. and Lee, J. H., 2007, Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 68-76 과학기술학회마을 |
70 | Cho, S. H. and Tae, C. S., 2007, Study on the Drag Reduction and Heat Transfer Efficiency Reduction of the Non-Ionic Surfactant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 133-141 과학기술학회마을 |
71 | Park, J. Y., Ko, S. B., Jun, H. H., Jun, Y. D. and Lee, K. B., 2007, A Study on the Performance and Dehumidification Load of an HVAC System for Conservation of Ancient Tombs, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 3, pp. 253-262 과학기술학회마을 |
72 | Lee, D. G., Peck, J. H., Hong, H. and Kang, C., 2007, Influence of the Supercooling Degree and Cooling Rate on a Continuous Ice Formation by a Supercooled Aqueous Solution in Flow Using a Plate Heat Exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 647-653 과학기술학회마을 |
73 | Yun, R., 2007, Evaluation of Performance of a Residential Air-Conditioning System Using Microchannel and Fin-and-Tube Heat Exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 28-35 과학기술학회마을 |
74 | Jeon, H. H., Ko, S. B. and Lee, K. B., 2007, A Numerical Study on Automobile Interior Environment, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 36-42 과학기술학회마을 |
75 | Park, K. J., Lee, M. H., Park, H. S. and Jung, D., 2007, Flow Condensation Heat Transfer Characteristicof Hydrocarbon Refrigerants and DME in Horizontal Plain Tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 545-554 과학기술학회마을 |
76 | Choi, Y. D. Kang, Y. T., Kim, N. H., Kim, M. H., Park, K. K., Park, B. Y., Park, J. C. and Hong, H., 2007, Recent Progress in Air Conditioning and Refrigeration Research, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 94-132 과학기술학회마을 |
77 | Jung, S. H., Kim, K., Hwang, K. M. and Song, S. Y., 2007, Experimental and Numerical Analysis in the Surroundings of Impingement Baffle Plate of the Extracting Nozzle for Disclosing Shell Wall Thinning of a Feedwater Heater, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 821-830 과학기술학회마을 |
78 | Cha, M. C., Yeo, M. S. and Seok, H. T., 2007, A Study on the Performance Evaluation of Recirculation System for Individual Hot Water Supply System in Residential Buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 857-864 과학기술학회마을 |
79 | Oh, K. J. and Kim, S. S., 2007, Development of an Axial F.R.P. Fan for Cooling Tower, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp. 735-742 과학기술학회마을 |
80 | Moon, Y. J., Noh, K. C. and Oh, M. D., 2007, Simplification of PMV through Multiple Regression Analysis, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 761-769 과학기술학회마을 |
81 | Yang, J. H., 2007, Examination of Airflow and Thermal Environment Characteristic around Human Body in a Room with Displacement Ventilation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 299-306 과학기술학회마을 |
82 |
Lee, C. S., Lee, K. Y., You, H. Y., Kang, B. H. and Park, K. K., 2007, Experimental Vapor-Liquid Equilibra for |
83 | Kim, W. N., Kim, Y. H. and Kim, S. Y., 2007, Performance Enhancement of a PEMFC by Modification of Air Inlet Flow Header Configuration, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 339-345 과학기술학회마을 |
84 | Kim, B. J., 2007, Air-water Countercurrent Flow Limitation in Narrow Rectangular Channels, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 441-446 과학기술학회마을 |
85 |
Kim, W. Y., Ahn, J. M., Kim, H. J. and Cho, S. O., 2007, Performance Analysis of a |
86 | Choi, J. M., Lee, K. N., Ryu, S. R., Kim, Y. Y., Yeo, M. S. and Kim, K. W., 2007, A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 1, pp. 77-85 과학기술학회마을 |
87 | Chin, Y., Moon, J. W., Lee, Y. P. and Chang, H. M., 2007, Thermodynamic Analysis of Re-liquefaction Cycle of LNG Boil-off Gas, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 485-490 과학기술학회마을 |
88 | Kim, Y. H., Ha, O. N., Lee, J. and Park, K., 2007, Shape Optimization of Internally Finned Tube with Helix Angle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 500-511 과학기술학회마을 |
89 | Kim, B., Peck, J. H., Hong, H. and Kang, C., 2007, Effect of Pressurization and Cooling Rate on Dissolution of a Stationary Supercooled Aqueous Solution, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 12, pp. 850-856 과학기술학회마을 |
90 | Yang, T. J., Kim, J. H., Youm, C. S., Kim, M. S. and Kim, J. S., 2007, Characteristics of Hydration Heat Control of Mass Concrete using Pulsating Heat Pipe in the Winter Season, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 169-174 과학기술학회마을 |
91 | Park, J. I., Kim, S. H. and Lee, S., 2007, Thermal Load Simulation Analysis on Model Building Estimating Optimum Heat Source Capacity, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 427-433 과학기술학회마을 |
92 | Chang, Y. S. and Lee, D. Y., 2007, Effects of Individual Components on the System Performance in a Desiccant Cooling System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 10, pp.687-694 과학기술학회마을 |
93 | Lee, S. J., Choi, J. Y., Lee, J. H. and Kwon, Y. C., 2007, Study on CO2 Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 615-621 과학기술학회마을 |
94 | Choi, W. K., Lee, K. Y., Lee, H. G. and Suh, S. J., 2007, Theoretical Analysis on the Applications of the Double-Floor Ondol System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 355-363 과학기술학회마을 |
95 | Lee, M. T., Kim, Y. and Kang, B. H., 2007, Dynamic Simulation of Ground Source Heat Pump with a Vertical U-tube Ground Heat Exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 5, pp. 372-378 과학기술학회마을 |
96 | Ko, S. B., Jun, Y. D. and Lee, K. B., 2007, Analysis of Particles Motion in Vertical Rayleigh Flow, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 447-456 과학기술학회마을 |
97 | Son, C. H. and Oh, H. K., 2007, Cooling Heat Transfer Characteristics of CO2 on Tube Geometry of Inclined Helical Coil Type Gas Coolers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 640-646 과학기술학회마을 |
98 | Jeong, J., Chae, H. M. and Kim, C. N., 2007, An Experimental Study on the Pumping Characteristics of Diffuser-Nozzle Based Thermopneumatic Micropumps with Different Input Voltages and Frequencies, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 654-661 과학기술학회마을 |
99 | Yee, J. J., Choi, S. Y., Kim, S. K., Kim, K. H., Lee, Y. W. and Kim, H. Y., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 770-775 과학기술학회마을 |
100 | Yoo, S. Y., Lee, D. W. and Kim, J. H., 2007, An Experimental Study on Performance Improvement of Automotive Air Handling System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 9, pp. 622-629 과학기술학회마을 |
101 | Soul, S. H., Jung, C. W. and Kim, J. S., 2007, A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 789-796 과학기술학회마을 |
102 | Sohn, B., 2007, Evaluation of Ground Effective Thermal Conductivity and Borehole Effective Thermal Resistance from Simple Line-Source Model, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 7, pp. 512-520 과학기술학회마을 |
103 | Yang, S., Lee, J. K., Kwon, J. T., Kim, S. N. and Kang, Y. T., 2007, The Experimental Study on The Counter-Current Flow Limit in The Flow Path with a Porous Plate, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 156-161 과학기술학회마을 |
104 | Park, K. K., Kang, B. H. and Jang, S., 2007, Comparison of Correlations of Saturated Vapor Density for Some Refrigerants, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 6, pp. 457-463 과학기술학회마을 |
105 | Park, J. I., Kim, S. H. and Kim, D. K., 2007, Analysis of Office Building HVAC System Drawings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 11, pp. 776-781 과학기술학회마을 |
106 | Kim, S. K. and Yee, J. J., 2007, The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 2, pp. 142-148 과학기술학회마을 |
107 | Koh, D. Y. and Lee, K. S., 2007, A Study SMES System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 328-332 과학기술학회마을 |
108 | You, H. J., Jung, E. J. and Kim, J. S. 2007, A Research on Vocabulary Materialization for Evaluation of Architecture Plumbing Noise, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 19, No. 4, pp. 346-354 과학기술학회마을 |
![]() |