• Title/Summary/Keyword: Drain Rate

Search Result 187, Processing Time 0.037 seconds

Salvage of Infected Breast Implants

  • Song, Joon Ho;Kim, Young Seok;Jung, Bok Ki;Lee, Dong Won;Song, Seung Yong;Roh, Tai Suk;Lew, Dae Hyun
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.516-522
    • /
    • 2017
  • Background Implant-based breast reconstruction is being performed more frequently, and implants are associated with an increased risk of infection. We reviewed the clinical features of cases of implant infection and investigated the risk factors for breast device salvage failure. Methods We retrospectively analyzed 771 patients who underwent implant-based breast reconstruction between January 2010 and December 2016. Age, body mass index, chemotherapy history, radiation exposure, and smoking history were assessed as potential risk factors for postoperative infection. We also evaluated the presence and onset of infection symptoms, wound culture pathogens, and other complications, including seroma, hematoma, and mastectomy skin necrosis. Additionally, we examined the mastectomy type, the use of acellular dermal matrix, the presence of an underlying disease such as hypertension or diabetes, and axillary node dissection. Results The total infection rate was 4.99% (58 of 1,163 cases) and the total salvage rate was 58.6% (34 of 58). The postoperative duration to closed suction drain removal was significantly different between the cellulitis and implant removal groups. Staphylococcus aureus infection was most frequently found, with methicillin resistance in 37.5% of the cases of explantation. Explantation after infection was performed more often in patients who had undergone 2-stage expander/implant reconstruction than in those who had undergone direct-to-implant reconstruction. Conclusions Preventing infection is essential in implant-based breast reconstruction. The high salvage rate argues against early implant removal. However, when infection is due to methicillin-resistant S. aureus and the patient's clinical symptoms do not improve, surgeons should consider implant removal.

The Behavior of the Mobility Degradation in Pocket Implanted MOSFETS (Halo 구조의 MOSFET에서 이동도 감소 현상)

  • Lee Byung-Heon;Lee Kie-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.4 s.334
    • /
    • pp.1-8
    • /
    • 2005
  • The increased effective impurity due to the pocket ion implantation is well blown to give rise to a reduction of the effective mobility of halo MOSFETs. However, further decrease of the effective mobility can be observed in pocket implanted MOSFETs above the mobility reduction due to the Coulomb impurity scattering and the gate bias dependency of the effective mobility can also differ from the simple model describing the mobility behavior in terms of the effective impurity. Phonon scattering and surface scattering as well as impurity Coulomb scattering are also shown to be effective in the degradation of the carrier mobility of pocket implanted MOSFETs. Using the 1-D regional approximation the effect of the distribution of the inversion charge density along the channel on the drain current is investigated. The inhomogeneous channel charge distribution due to pocket implantation is also shown to contribute to the further reduction of the effective mobility in halo MOSFETs.

Chemical Pleurodesis Using Doxycycline and Viscum album Extract

  • Song, Kyung Sub;Keum, DongYoon;Kim, Jae Bum
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.281-286
    • /
    • 2017
  • Background: In chemical pleurodesis for managing pulmonary air leak, tetracycline derivatives are commonly used, and their effectiveness has been established in many studies. Recently, a Viscum album extract was used in chemical pleurodesis. We compared the effects of V. album with those of a tetracycline derivative (doxycycline) to demonstrate the therapeutic effectiveness of the V. album extract in chemical pleurodesis for managing pulmonary air leak. Methods: Between October 2010 and October 2016, chemical pleurodesis was performed using doxycycline in 40 patients and the V. album extract in 37 patients. Thirty-three patients were in the postoperative state after pulmonary resection, and 44 patients suffered from spontaneous pneumothorax. Results: No statistically significant difference in the success rate was observed between the 2 groups (V. album extract and doxycycline). In both groups, chest pain was the most common complication. More patients in the doxycycline group complained of severe chest pain (42.1% vs. 13.5%, p=0.006). In the V. album extract group, 24.3% of the patients required a chest tube to drain the pleural effusion after cessation of the air leak (doxycycline group: 5%, p=0.022). Further, the amount of pleural effusion drained on the day after the last chemical pleurodesis in the V. album extract group was greater than that in the doxycycline group ($162.2{\pm}170.2mL$ vs. $97.0{\pm}77.2mL$, p=0.032). All patients were discharged from the hospital without complications after pleural effusion drainage. Conclusion: Considering that treatment using the V. album extract was less painful, V. album might be a feasible option for chemical pleurodesis. However, pleural effusion should be monitored carefully when using V. album extract for treating patients suffering from air leak.

A kinetic study of 4-chlorophenol biodegradation by the novel isolated Bacillus subtilis in batch shake flask

  • Sandhibigraha, Sudhansu;Chakraborty, Sagnik;Bandyopadhyay, Tarunkanti;Bhunia, Biswanath
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.62-70
    • /
    • 2020
  • Here in this work, a 4-chlorophenol (4-CP)-degrading bacterial strain Bacillus subtilis (B. subtilis) MF447840.1 was isolated from the drain outside the Hyundai car service center, Agartala, Tripura, India. 16S rDNA technique used carried out for genomic recognition of the bacterial species. Isolated bacterial strain was phylogenetically related with B. subtilis. This strain was capable of breaking down both phenol and 4-CP at the concentration of 1,000 mg/L. Also, the isolated strain can able to metabolize five diverse aromatic molecules such as 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, 4-nitrophenol, and pentachlorophenol for their growth. An extensive investigation was performed to portray the kinetics of cell growth along with 4-CP degradation in the batch study utilizing 4-CP as substrate. Various unstructured models were applied to evaluate the intrinsic kinetic factors. Levenspiel's model demonstrates a comparatively enhanced R2 value (0.997) amongst every analyzed model. The data of specific growth rate (μ), saturation constant (KS), and YX/S were 0.11 h-1, 39.88 mg/L, along with 0.53 g/g, correspondingly. The isolated strain degrades 1,000 mg/L of 4-CP within 40 h. Therefore, B. subtilis MF447840.1 was considered a potential candidate for 4-CP degradation.

Formation of Nickel Silicide from Atomic Layer Deposited Ni film with Ti Capping layer

  • Yun, Sang-Won;Lee, U-Yeong;Yang, Chung-Mo;Na, Gyeong-Il;Jo, Hyeon-Ik;Ha, Jong-Bong;Seo, Hwa-Il;Lee, Jeong-Hui
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.193-198
    • /
    • 2007
  • The NiSi is very promising candidate for the metallization in 60nm CMOS process such as FUSI(fully silicided) gate and source/drain contact because it exhibits non-size dependent resistance, low silicon consumption and mid-gap workfunction. Ni film was first deposited by using ALD (atomic layer deposition) technique with Bis-Ni precursor and $H_2$ reactant gas at $220^{\circ}C$ with deposition rate of $1.25{\AA}/cycle$. The as-deposited Ni film exhibited a sheet resistance of $5{\Omega}/{\square}$. RTP (repaid thermal process) was then performed by varying temperature from $400^{\circ}C$ to $900^{\circ}C$ in $N_2$ ambient for the formation of NiSi. The process window temperature for the formation of low-resistance NiSi was estimated from $600^{\circ}C$ to $800^{\circ}C$ and from $700^{\circ}C$ to $800^{\circ}C$ with and without Ti capping layer. The respective sheet resistance of the films was changed to $2.5{\Omega}/{\square}$ and $3{\Omega}/{\square}$ after silicidation. This is because Ti capping layer increases reaction between Ni and Si and suppresses the oxidation and impurity incorporation into Ni film during silicidation process. The NiSi films were treated by additional thermal stress in a resistively heated furnace for test of thermal stability, showing that the film heat-treated at $800^{\circ}C$ was more stable than that at $700^{\circ}C$ due to better crystallinity.

  • PDF

Characteristics of Quasi-MFISFET Device with Various Ferroelectric Thin Films (강유전체 박막의 특성에 따른 Quasi-MFISFET 소자의 특성)

  • Lee, Guk-Pyo;Yun, Yeong-Seop;Gang, Seong-Jun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.166-173
    • /
    • 2001
  • Hysteresis loops of the ferroelectric thin films such as PLZT(10/30/70), PLT(10) and PZT(30/70) was simulated using the field-dependent polarization model and compared to the measured loops. In case of PZT(30/70) thin film, as the real saturation or polarization at the applied voltage or larger than 5V appears slack and its value is quite different from the simulated one, it is deduced that the ferroelectric polarization of PZT(30/70) is generated not only by the pure dipoles but also by various electric charges. The drain current of quasi-MFISFET is expressed by using the square-law FET and field-dependent polarization models. The modeling results are analogous to the experimental values. The channel of quasi-MFISFET using PZT(30/70) forms more quickly compared to that of quasi-MFISFET using PLZT(10/30/70) or PLT(10) in the state of 'write' gate voltage of -10V. This may be because the decrease rate of the polarization in the PZT(30/70) thin film is 3~4 times more rapid than that of the polarization in the PLZT(10/30/70) or the PLT(10) thin film in the retention characteristics.

  • PDF

Comparison of Filtration Efficiency of Membranes for Harvesting Microalgae using a Gravity-Filtration Device (중력 여과장치 이용 미세조류 수확을 위한 여과막의 효율성 비교)

  • Shin, Dong-Woo;Cho, Yonghee;Kim, Ki-Hyun;Kim, HanByeol;Park, Hanwool;Kim, Z-Hun;Lim, Sang-Min;Lee, Choul-Gyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.9 no.1
    • /
    • pp.8-13
    • /
    • 2017
  • Cost-effective microalgae harvesting methods are necessary for economical production of algal biodiesel. In this study, membranes with various pore sizes and materials were examined for their potentials in application to gravity-filtration of Tetraselmis sp. KCTC12432BP. For this test, 10 L of Tetraselmis sp. culture (2 g/L) was loaded on each membrane and filtration rates were measured. Among the tested materials, a woven cotton fabric showed the fastest water drain rate (0.73 L/hr) without serious cell leakage. Cell density of the concentrates after filtration was 6.8 g/L, indicating 3.4-fold concentration compared with the initial algal culture. The result suggests that the woven cotton fabric could serve as filtration membrane for harvesting Tetraselmis sp. among the tested ones.

Performance Evaluation of Soil Vapor Extraction Using Prefabricated Vertical Drain System (연직배수시스템을 이용한 토양증기추출공법의 성능 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.9-18
    • /
    • 2007
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. Incorporating PVDs in an SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. The objective of the research described herein was to effectively incorporate PVDs into a SVE remediation system. The test results show that the gas permeability was evaluated for four different equivalent diameters, increasing the equivalent diameter results in a decrease in the calculated gas permeability. It was found that the porosity for the dry condition was greater than that of the wet condition and will allow flow rate for the same vacuum flow, offering a low resistance to the air flow.

Employment Structure of University Graduates and Regional Development: A Case Study of Chonnam National University (전남대학교 졸업생의 취업구조와 지역발전)

  • 안영진
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.37-56
    • /
    • 2001
  • Regarding human capital development and the competitive advantage of regional economies, the transfer of local university graduates to the local labor market is a very important factor. This study aims to investigate the employment structure of university graduates and spatial patterns of their jobs, and the job search strategies to enter the employment system with a case study of Chonnam National University graduates. Because of the lagged industrial structure and peripheral location of Kwangju/Chonnam Province, the employment rate of the university graduates is generally lower than a national average. And there is a strong tendency of the concentration of job places on the metropolitan areas on the one hand, and on the Kwangju/chonnarn and Capital region of Korea on the other. University graduates in searching for jobs especially prefer spatial mobility toward job opportunities In other regions to promoting the flexibility of job qualifications to meet labor market demands. Based on the results of the study, we can identify a process of so-called train drains'in both quantitative and qualitative terms, and conclude that the role of the Chonnam National University in promoting regional development potentials and local labor market conditions is Quite restrictive.

  • PDF

Design and Fabrication of CMOS Micro Humidity Sensor System (CMOS 마이크로 습도센서 시스템의 설계 및 제작)

  • Lee, Ji-Gong;Lee, Sang-Hoon;Lee, Sung-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.146-153
    • /
    • 2008
  • Integrated humidity sensor system with two stages operational amplifier has been designed and fabricated by $0.8{\mu}m$ analog mixed CMOS technology. The system (28 pin and $2mm{\times}4mm$) consisted of Wheatstone-bridge type humidity sensor, resistive type humidity sensor, temperature sensors and operational amplifier for signal amplification and process in one chip. The poly-nitride etch stop process has been tried to form the sensing area as well as trench in a standard CMOS process. This modified technique did not affect the CMOS devices in their essential characteristics and gave an allowance to fabricate the system on same chip by standard process. The operational amplifier showed the stable operation so that unity gain bandwidth was more than 5.46 MHz and slew rate was more than 10 V/uS, respectively. The drain current of n-channel humidity sensitive field effect transistor (HUSFET) increased from 0.54 mA to 0.68 mA as the relative humidity increased from 10 to 70 %RH.

  • PDF