• 제목/요약/키워드: Down conductor

검색결과 40건 처리시간 0.024초

인하도선 주변에서 발생하는 자장의 억제 (The Control of the Magnetic Field around Down Conductors)

  • 이복회;강성만;이승칠;엄주흥;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.216-218
    • /
    • 2001
  • This paper deals with the control of magnetic field around the down conductor of lightning protection systems. The magnetic field strength in the vicinity of down conductor is shown to drop off rapidly with distance from the down conductor and is reversely proportional to the number of down conductor. Also the magnetic field strength is decreased in the structures as the down conductor is installed with the symmetrical arrangement, and it is zero at the center of symmetry. The magnetic field strengths for the symmetrical arrangement of two down conductors are less than one half compared with that for a down conductor. A proper arrangement of down conductor can reduce or cancel the magnetic field in a restricted place where information-oriented and computerized facilities are densely installed.

  • PDF

인하도선시스템 시설에서의 문제점과 대책 (Problems and Countermeasures in Installation of Down Conductor Systems)

  • 이복희;이동문;강성만;엄주홍;정동철;이승칠;안창환
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.38-45
    • /
    • 2002
  • 내본 논문에서는 뇌서지에 의해서 발생하는 컴퓨터를 비롯한 전자기기의 장해에 대한 보호대책을 제안하기 위해서내 국내의 뇌보호설비에 대한 규격과 지침에 대한 기술적인 문제점을 분석하였다. 인하도선의 설치방법에 따른 인하도선과 인입용 금속관을 통하여 흐르는 전류사이의 관계를 검토하였으며, 인하도선계에 미치는 표피효과의 영향을 평가하는 실험을 수행하였다. 그 결과 인하도선을 인입용 금속관에 전기적으로 접속한 때 인하도선과 금속관은 하나의 도체로 작용하며, 표피효과와 쵸킹효과 때문에 뇌격전류는 인하도선보다도 금속관을 통하여 훤씬 많은 전류가 흘렀다. 따라서 뇌격전류에 의한 인하도선의 전위상승으로 야기되는 정전유도와 측면방전 등의 악영향을 억제하기 위해서는 인하도선을 인입용 금속관과 건물의 철골 구조체에 전기적으로 접속하는 것이 매우 효과적이다.

인하도선으로 활용하기 위한 철근콘크리트구조물의 전기 및 기계적 소요 특성에 대한 실험적 검증 (Experimental Verification on the Use of Steelwork as a Down-Conductor in Lightning Protection System)

  • 이기홍
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.94-99
    • /
    • 2011
  • This paper verified the characteristics of electrical continuity and mechanical strength of steelwork required to use it as a down-conductor in lightning protection system. It was proven that the steelwork in reinforced concrete apartment has an excellent electrical continuity with low resistance(less than 0.2[${\Omega}$].). But it was confirmed that a poor connection between two reinforcement bars can easily cause serious damages of the concrete even with the impulsive current of 50[kA], 10/350[${\mu}s$]. These results of experiments mean that the additional measures are necessary in using the steelwork as the down-conductor of the lightning protection system.

임펄스전류에 의한 인하도선 주위에서 자속밀도의 분포 (Distributions of the Magnetic Flux Density Near Down-Conductors Due to Various Impulse Currents)

  • 이복희;장근철;이수봉;강성만;이승칠
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권2호
    • /
    • pp.109-115
    • /
    • 2004
  • This paper deals with the behaviors of magnetic flux density near down-conductors by lightning currents. The background on the principle of magnetic flux density measurements using the RL self-integrating magnetic field sensor was described. The magnetic flux density measuring device consisting of RL self-integrating magnetic field sensor and differential amplifier was designed and fabricated. The frequency bandwidth of the magnetic flux density measuring system ranges from 200 Hz to 300 KHz and the response sensitivity was 0.126 $\mu$T/㎷ The distributions of the magnetic flux density near down-conductors due to impulse currents with various rise times were analyzed as a parameter of the bonding conditions and materials of conductor and wiring conduits. The magnetic flux density due to impulse currents was inversely proportional to the distance between the down-conductor and measuring point. The amplitude of the magnetic flux density for PVC Pipe with down-conductor was 72 $\mu$T/㎷ at the distance of 1m and was higher than for steel conduits and coaxial cable. Finally the magnetic flux density is increased with increasing the di/dt it and oscillation frequency of lightning currents in this experimental ranges.

인하도선 길이에 따른 과도접지임피던스 특성 (Effects of Length of Down Conductor on Transient Ground Impedance)

  • 이복희;정동철;이수봉;이태형;정현욱;이규선;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2235-2237
    • /
    • 2005
  • This paper presents the transient impedance behaviors of grounding systems to lightning impulse current. The potential rise and effective impulse ground impedance of the test grounding electrodes were measured as a function of the rise time of impulse currents and lengths of down conductor. The transient ground impedances strongly depend on the configuration and size of grounding electrodes, the impulse current shapes and lengths of down conductor, and the inductance of reduce of grounding electrode inductance is an important factor to improve the transient ground impedance.

  • PDF

뇌보호시스템에서 인하도선의 효과적인 설치기법 (Effective Installation Methods of Down Conductors in Lightning Protection Systems)

  • 이복희;엄주홍;이승칠;강성만
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.8-14
    • /
    • 2002
  • 현대의 뇌보호시스템은 낙뢰로 인한 감전이나 건축물, 전기·전자기기의 파손과 같은 위험성을 제거하는 것이 요구되지만 종래의 뇌보호설비는 단지 인명의 피해나 건축물을 보호하는 것이 주된 역할이었다. 오늘날 컴퓨터, 정보통신설비 등을 효과적으로 보호할 수 있는 뇌보호설비가 필수적 요건으로 대두되었다. 본 논문에서는 뇌과전압으로부터 컴퓨터와 전자장비를 보호할 수 있는 기술을 개발할 목적으로 인하도선의 종류와 설치기법에 따라서 인하도선에 유도되는 전위상승 억제에 대한 연구를 수행하였다. 그 결과 인하도선의 전위상승에 의한 측면방전과 위험성을 줄이기 위해서는 인하도선으로 낮은 특성임피던스를 가지는 동축케이블이 적당하며, 인하도선과 금속관을 상단과 하단에서 본딩하는 방법이 효과가 높게 나타났다.

뇌보호설비용 인하도선의 설치조건에 따른 전위상승 (Potential Rises of Down-conductor for Lightning Protection System according to Establishment Conditions)

  • 이복희;강성만;이승칠;이동문;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1724-1726
    • /
    • 2001
  • This paper deals with the characteristics of the potential rises of down-conductor due to lightning surge currents. Direct lightning strikes can cause high impulse currents to the lightning protection system(LPS) of a building. These high impulse currents have the front time as short as 1[${\mu}s$]. In this case, the induced voltages caused in a closed circuit inside the building can be very high and cause damage or submit people to electric hazard. So, the LPS has to be designed to ensure safety condition to person and acceptable levels of induced voltages to the electrical and electronic equipments. The results of the potential rises related to the bonding conditions between the grounding conductor and metal raceway and the type of down-conductors are introduced.

  • PDF

공동주택에서의 인하도선시스템과 접지시스템 설계에 대한 고찰 (Considerations in Down-conductor System and Earth-termination System Design of Apartments)

  • 이기홍;이재복;장석훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.54-58
    • /
    • 2006
  • 본 논문에서는 공동주택에 적합한 인하도선시스템과 접지시스템 설계를 위한 기본적 사항에 대하여 고찰하였다. 공동주택의 철근구조체는 전기적 연속성을 갖지만 철근들끼리의 결속선에 의한 접속은 전자기계력에 대한 내력이 부족하다. 따라서 전용의 인하도선을 설치하고 이들을 건물 양 측벽의 철근구조체와 본딩하여 낙뢰전류가 인하도선 및 철근구조체에 분산되어 흐르게 하는 인하도선시스템을 제시하였다. 한편 공동주택의 접지시스템은 건물기초접지극과 피뢰설비를 위한 환형 접지극으로 각각 구성하고 이들을 서로 본딩하는 접지시스템을 제시하였다. 또한 공동주택 각동의 건물기초접지극을 공동구의 철근구조체나 접지선을 이용하여 서로 연결함으로서 공동주택 단지에 거대한 총괄접지시스템을 구현하는 방안을 제시하였다. 하지만 이러한 피뢰시스템을 구축하기 위해서는 완벽한 본딩시스템의 구축이 전제되어야 한다.

  • PDF

인하도선의 길이가 과도접지임피던스에 미치는 영항 (Effects of the Length of Down Conductors on Transient Ground Impedances)

  • 이복희;이수봉;정동철
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.72-77
    • /
    • 2006
  • 본 논문은 인하도선의 설치에 따른 접지시스템의 임펄스전류에 대한 과도임피던스 특성을 다루었다. 임펄스전류를 심매설 봉상 접지전각과 그리드 접지전극에 인가하였을 때 임펄스전류의 상승시간과 인하도선의 길이에 따른 전위상승과 실효임펄스접지임피던스를 측정하고 분석하였다. 과도접지임피던스는 접지전극의 형상과 크기 및 임펄스전류의 파형과 인하도선의 길이에 강하게 의존하며, 인덕턴스가 최소화되도록 인하도선을 설치하는 기법이 과도접지 임피던스의 저감을 위한 중요한 요소이다.

외부 전류가 흐를 때 초전도 선재에서의 전류 분포 (current profiles in a coated conductor with transport current)

  • 유재은;이상무;정예현;이재영;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.1-4
    • /
    • 2007
  • The current profiles in a coated conductor with transport current were calculated using an iterative inversion method from the data of the magnetic flux density profiles measured. The applied current was increased from 0 to 60 A by 10A step and decreased down to -60A by 20A step. The magnetic flux profiles were measured at a distance of 400 mm above the surface of the coated conductor using a scanning hall probe method. The current profiles calculated were very different from the Bean model: current density profile is not a constant in the critical region. However the aspect of the change of the current and magnetic flux density profiles in the case of decreasing applied current are similar to the theoretical calculations in Brandt's paper.