Characterization of Double-layer Optical Sensing Membranes for Dual Sensing of Dissolved Oxygen Concentrations and pH and Their Application to the On-line Monitoring of Fermentation Processes (용존산소농도와 pH의 동시 검출용 이중층 광학 센서막의 특성 및 발효공정의 온라인 모니터링에의 응용)

  • Kim, Chun-Kwang;Lee, Jong-Il
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • A double-layer optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen (DO) and pH value simultaneously. (tris(4,7-diphenyl-1,10-phenanthroline (Rudpp) ruthenium(II)) as a DO sensitive dye has been mixed in the methyl trimethoxy silane (MTMS) sol-gel solution and coated onto one well in a 24-well microtiter plate. On the DO-sensing layer the GA (3-glycidoxypropyl trimethoxy silane (GPTMS), 3-aminopropyl trimethoxy silane (APTMS)) sol-gel solution mixed with 8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS) has been coated and used to measure pH values. The double-layer sensing membrane was affected by ionic strength and temperature. The double-layer sensing membrane for DO and pH has been applied to online monitor in microorganism cultivation processes and showed a good performance.

Development of a Double-blades Road Cutter with Automatic Cutting and Load Sensing Control Technology (자동 절단과 부하 감응 제어 기술을 적용한 양날 도로절단기 개발)

  • Myoung Kook Seo;Myeong Cheol Kang;Jong Ho Park;Young Jin Kim
    • Journal of Drive and Control
    • /
    • v.21 no.1
    • /
    • pp.53-58
    • /
    • 2024
  • With the recent development of intelligence and automation technologies for construction machinery, the demand for safety and efficiency of road-cutting operations has continued to increase. In response to this, a double-blade road cutter has been developed that can automatically cut roads. However, a double-blade road cutter has a load difference between the two blades due to the ground and wear conditions of the cutting blades. The difference in load between the two blades distorts the direction of travel of the cutter. In this study, a vision sensor-based driving guide technology was developed to correct the driving path of road cutters. In addition, we developed a load-sensing technology that detects blade loads in real-time and controls driving speed in the event of overload.

A Novel Cluster-Based Cooperative Spectrum Sensing with Double Adaptive Energy Thresholds and Multi-Bit Local Decision in Cognitive Radio

  • Van, Hiep-Vu;Koo, In-Soo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.5
    • /
    • pp.461-474
    • /
    • 2009
  • The cognitive radio (CR) technique is a useful tool for improving spectrum utilization by detecting and using the vacant spectrum bands in which cooperative spectrum sensing is a key element, while avoiding interfering with the primary user. In this paper, we propose a novel cluster-based cooperative spectrum sensing scheme in cognitive radio with two solutions for the purpose of improving in sensing performance. First, for the cluster header, we use the double adaptive energy thresholds and a multi-bit quantization with different quantization interval for improving the cluster performance. Second, in the common receiver, the weighed HALF-voting rule will be applied to achieve a better combination of all cluster decisions into a global decision.

A Study on Fiber Optic Hydrophone with Double Interferometers for Optical Path Length Compensation

  • Kim, Jeong-suk;Yoon, Hyun-gyu;Seol, Jae-soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1E
    • /
    • pp.25-30
    • /
    • 2002
  • We report on the development of a fiber optic hydrophone consists of a sensing Michelson interferometer and a compensating Mach-Zehnder interferometer for optical path length compensation. The double interferometer configuration has the following advantages: the hydrophone can be made more small; a laser source with a relatively short coherence length can be used; and the compensating interferometer can be located near the signal processing electronics, far away from the sensing interferometer and noise introduced by reference arm can be greatly reduced. The performance of the hydrophone is evaluated experimentally by immersing the sensing interferometer in a water tank to detect underwater acoustic signals generated by an acoustic wave projector. Experimental results show that over the frequency range of 1 to 4 kHz, the hydrophone has an almost flat response with an average normalized sensitivity of -302 dB re 1/ μ Pa.

Double-Side Notched Long-Period Fiber Gratings fabricated by Using an Inductively Coupled Plasma for Force Sensing

  • Fang, Yu-Lin;Huang, Tzu-Hsuan;Chiang, Chia-Chin;Wu, Chao-Wei
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1399-1404
    • /
    • 2018
  • This study used an inductively coupled plasma (ICP) dry etching process with a metal amplitude mask to fabricate a double-side notched long-period fiber grating (DNLPFG) for loading sensing. The DNLPFG exhibited increasing resonance attenuation loss for a particular wavelength when subjected to loading. When the DNLPFG was subjected to force loading, the transmission spectra were changed, showing a with wavelength shift and resonance attenuation loss. The experimental results showed that the resonant dip of the DNLPFG increased with increasing loading. The maximum resonant dip of the $40-{\mu}m$ DNLPFG sensor was -26.522 dB under 0.049-N loading, and the largest force sensitivity was -436.664 dB/N. The results demonstrate that the proposed DNLPFG has potential for force sensing applications.

Liquid level measurement system using capacitive sensor and optical sensor

  • Shim, Joonhwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.778-783
    • /
    • 2013
  • Measurement of liquid level in storage and processing vessels, tanks, wells, reservoirs and hoppers is commonly needed. The several different ways to measure the liquid level of oil or water tank have been provided such as an electrostatic capacity, a supersonic waves and an optical science etc. In the study, we have constructed the stable and efficient measurement system to measure the level of liquid at real-time and to get accurate measurement of the maximum and minimum level of the tank. For this purpose, we suggest double sensing methods by adopting both capacitive and optical sensing. The experimental results, presented in this paper, illustrate the effectiveness of the proposed method under different sensing methods.

Two-Stage Spectrum Sensing Scheme Using Fuzzy Logic for Cognitive Radio Networks

  • Satrio, Cahyo Tri;Jaeshin, Jang
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Spectrum sensing in cognitive radio networks allows secondary users to sense the unused spectrum without causing interference to primary users. Cognitive radio requires more accurate sensing results from unused portions of the spectrum. Accurate spectrum sensing techniques can reduce the probability of false alarms and misdetection. In this paper, a two-stage spectrum sensing scheme is proposed for cooperative spectrum sensing in cognitive radio networks. In the first stage, spectrum sensing is executed for each secondary user using energy detection based on double adaptive thresholds to determine the spectrum condition. If the energy value lies between two thresholds, a fuzzy logic scheme is applied to determine the channel conditions more accurately. In the second stage, a fusion center combines the results of each secondary user and uses a fuzzy logic scheme for combining all decisions. The simulation results show that the proposed scheme provides increased sensing accuracy by about 20% in some cases.

Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones (다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서)

  • Lee Dong Woo;Yi Soyeon;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

Performance Analysis of an Energy Detection Based Cooperative Spectrum Sensing with Double Thresholds in the Presence of Noise Uncertainty (잡음 전력의 불확실성이 존재하는 환경에서 이중 임계값을 사용하는 에너지 검파 기반 협력 스펙트럼 감지의 성능 분석)

  • Lim, Chang Heon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.15-20
    • /
    • 2013
  • An energy detection based spectrum sensing is widely known to be susceptible to the noise power uncertainty. As one of the methods to resolve this problem, a cooperative spectrum sensing based on an energy detector with double thresholds has been published recently. However, its performance analysis under a fading channel has not been carried out yet. In this paper, we present a closed form of performance analysis of the scheme by extending our previous work on evaluating the performance of an energy detector in the presence of noise power uncertainty.

A multi-point sense amplifier for embedded SRAM

  • 장일관;김진국;이승민;곽계달
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.526-529
    • /
    • 1998
  • This paper describes new sense amplifier with fast sensing delay time of 0.54ns and 32kb CMOS embedded SRAM with 4.67ns access time for a 3-V powr supply. It was achieved using the sense amplifier with multiple point sensing scheme and high speed bit-line scheme. The sense amplifier saves 25% of the power dissipation compared with the conventional one while maintaining a very short sensing delay. The SRAM uses 0.5.mu.m double-polysilicon and triplemetal CMOS process technology. A die size is 1.78mm*2.13mm.

  • PDF