Electrical Characteristic of Power MOSFET with Zener Diode for Battery Protection IC

  • Kim, Ju-Yeon;Park, Seung-Uk;Kim, Nam-Soo;Park, Jung-Woong;Lee, Kie-Yong;Lee, Hyung-Gyoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • A high power MOSFET switch based on a 0.35 ${\mu}m$ CMOS process has been developed for the protection IC of a rechargeable battery. In this process, a vertical double diffused MOS (VDMOS) using 3 ${\mu}m$-thick epi-taxy layer is integrated with a Zener diode. The p-n+Zener diode is fabricated on top of the VDMOS and used to protect the VDMOS from high voltage switching and electrostatic discharge voltage. A fully integrated digital circuit with power devices has also been developed for a rechargeable battery. The experiment indicates that both breakdown voltage and leakage current depend on the doping concentration of the Zener diode. The dependency of the breakdown voltage on doping concentration is in a trade-off relationship with that of the leakage current. The breakdown voltage is obtained to exceed 14 V and the leakage current is controlled under 0.5 ${\mu}A$. The proposed integrated module with the application of the power MOSFET indicates the high performance of the protection IC, where the overcharge delay time and detection voltage are controlled within 1.1 s and 4.2 V, respectively.

Comparative Study of Clinical and Radiological Outcomes of a Zero-Profile Device Concerning Reduced Postoperative Dysphagia after Single Level Anterior Cervical Discectomy and Fusion

  • Son, Doo Kyung;Son, Dong Wuk;Kim, Ho Sang;Sung, Soon Ki;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.103-107
    • /
    • 2014
  • Objective : This study analyzed clinical and radiological outcomes of a zero-profile anchored spacer (Zero-P) and conventional cage-plate (CCP) for single level anterior cervical discectomy and fusion (ACDF) to compare the incidence and difference of postoperative dysphagia with both devices. Methods : We retrospectively reviewed our experiences of single level ACDF with the CCP and Zero-P. From January 2011 to December 2013, 48 patients who had single level herniated intervertebral disc were operated on using ACDF, with CCP in 27 patients and Zero-P in 21 patients. Patients who received more than double-level ACDF or combined circumferential fusion were excluded. Age, operation time, estimated blood loss (EBL), pre-operative modified Japanese Orthopaedic Association (mJOA) scores, post-operative mJOA scores, achieved mJOA scores and recovery rate of mJOA scores were assessed. Prevertebral soft tissue thickness and postoperative dysphagia were analyzed on the day of surgery, and 2 weeks and 6 months postoperatively. Results : The Zero-P group showed same or favorable clinical and radiological outcomes compared with the CCP group. Postoperative dysphagia was significantly low in the Zero-P group. Conclusions : Application of Zero-P may achieve favorable outcomes and reduce postoperative dysphagia in single level ACDF.

Transmitted Noise Reduction of Piezoelectric Smart Panels using Passive/Active Method in Wide Range frequency (수동/능동적 방법을 혼용한 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;박우철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • In this paper, the transmitted noise reduction performance of piezoelectric smart panels is experimentally studied. The proposed piezoelectric smart panels are comprised of plate structure on which piezoelectric sensor/actuators are bonded and sound absorbing material is provided. It is a combination of passive and active approaches utilizing a passive effect at high frequencies and an active effect at low frequencies. To prove the concept of piezoelectric smart panels, an acoustic measurement experiment is performed. An acoustic tunnel is designed and its acoustic characteristics are tested. Below 800Hz, the tunnel exhibits a plane wave guide characteristics. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in mid frequency range is observed except the first resonance frequency. By enabling the active control of single smart panel with negative feedback control. about 10dB noise reduction is achieved at the resonance frequencies. The double smart panel got 4dB at the first resonance frequency and has more potential to reduce the transmitted noise in a wide range frequency. Piezoelectric smart panels incorporating passive absorbing material and active piezoelectric devices is a promising technology for noise reduction in a wide range frequency.

  • PDF

Power Fluctuation Reduction of Pitch-Regulated MW-Class PMSG based WTG System by Controlling Kinetic Energy

  • Howlader, Abdul Motin;Urasaki, Naomitsu;Yona, Atsushi;Senjyu, Tomonobu;Saber, Ahmed Yousuf
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.116-124
    • /
    • 2012
  • Wind is an abundant source of natural energy which can be utilized to generate power. Wind velocity does not remain constant, and as a result the output power of wind turbine generators (WTGs) fluctuates. To reduce the fluctuation, different approaches are already being proposed, such as energy storage devices, electric double layer capacitors, flywheels, and so on. These methods are effective but require a significant extra cost to installation and maintenance. This paper proposes to reduce output power fluctuation by controlling kinetic energy of a WTG system. A MW-class pitch-regulated permanent magnet synchronous generator (PMSG) is introduced to apply a power fluctuation reducing method. The major advantage of this proposed method is that, an additional energy storage system is not required to control the power fluctuation. Additionally, the proposed method can mitigate shaft stress of a WTG system. Which is reflected in an enhanced reliability of the wind turbine. Moreover, the proposed method can be changed to the maximum power point tracking (MPPT) control method by adjusting an averaging time. The proposed power smoothing control is compared with the MPPT control method and verified by using the MATLAB SIMULINK environment.

The study of electrode for energy storaging at supercapacitor system using nano carbon fiber material (나노 탄소재료를 이용한 에너지 저장형 슈퍼커패시터용 전극 제조)

  • Hwang, Sung-Ik;Choi, Won-Kyung;Momma, Toshiyukl;Osaka, Tetsuya;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.683-686
    • /
    • 2004
  • In recent years, the supercapacitor and hybrid capacitor have related with substitutional energy source focused of many scientists because of their usage in power sources for electric vehicles, computers and other electric devices. The storage energy of electrical charge is based on electrostatic interactions in the electric double layer at the electrode/electrolyte interface, resulting in high rate capability and long cycle performance compared with batteries based on Faradaic electrode reactions. So we have been considered to carbon nanofibers as the ideal material for supercapacitors due to their high utilization of specific surface area, good conductivity, chemical stability and other advantages. In this work, we aimed to find out that the capacitance have increased because of electrochemical capacitance to provide by carbon nanofibers. Also carbon nanofibers based on chemical method and water treatment have been resulted larger capacitances and also exhibit better electrochemical behaviors about 15% than before of nontreated state. And also optical observations with treated and nontrteated carbon nanofibers discussed by the TEM, SEM, EDX, BET works and specific surface area analyzer. Their results also focused on the surface area of electrode and electrical capacitance was also improved by the effect of surface treatments.

  • PDF

fabrication of Self-Aligned Mo2N/MO-Gate MOSFET and Its Characteristics (자기 정렬된 Mo2N/Mo 게이트 MOSFET의 제조 및 특성)

  • 김진섭;이종현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.6
    • /
    • pp.34-41
    • /
    • 1984
  • MOEN/MO double layer which is to be used It)r the RMOS (refractory metal oxide semiconductor) gate material has been fabricated by means of low temperature reactive sputtering in N2 and Ar mixture. Good Mo2N film was obtained in the volumetric mixture of Ar:N2=95:5. The sheet resistance of the fabricated Mo7N film was about 1.20 - 1.28 ohms/square, which is about an order of magnitude lower than that of polysilicon film, and this would enable to improve the operational speed of devices fabricated with this material. When PSG (phosphorus silicate glass) was used as impurity diffusion source for the source and drain of the RMOSFET in the N2 atmosphere at about 110$0^{\circ}C$, the Mo2N was reduced to Mo resulting in much smaller sheet resistance of about 0.38 ohm/square. The threshold voltage of the RMOSFET fabricated in our experiment was - 1.5 V, and both depletion and enhancement mode RMOSFETs could be obtained.

  • PDF

Linearity Enhancement of Partially Doped Channel GaAs-based Double Heterostructure Power FETs (부분 채널도핑된 GaAs계 이중이종접합 전력FET의 선형성 증가)

  • Kim, U-Seok;Kim, Sang-Seop;Jeong, Yun-Ha
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.1
    • /
    • pp.83-88
    • /
    • 2002
  • To increase the device linearities and the breakdown-voltages of FETs, $Al_{0.25}$G $a_{0.75}$As/I $n_{0.25}$G $a_{0.75}$As/A $l_{0.25}$G $a_{0.75}$As partially doped channel FET(DCFET) structures are proposed. The metal insulator-semiconductor(MIS) like structures show the high gate-drain breakdown voltage(-20V) and high linearities. We propose a partially doped channel structure to enhance the device linearity to the homogeneously doped channel structure. The physics of partially doped channel structure is investigated with 2D device simulation. The devices showed the small ripple of the current cut-off frequency and the power cut-off frequency over the wide bias range. bias range.

A Reliable Study on the Accident Reconstruction using Accident Data Recorder (사고기록장치를 이용한 교통사고재현에 관한 신뢰성 연구)

  • Baek, Se-Ryong;Cho, Joeng-Kwon;Park, Jong-Jin;Lim, Jong-Han
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.179-187
    • /
    • 2014
  • As an Accident data recorder (ADR) is a system to record a vehicle's status and dynamics information on the before and after of accident, Traffic accident investigation agencies and parts developers have a lot of interest to analyze an accident objectively and develop automotive safety devices by using real accident data, This study is to analyze an accident objectively and scientifically on the basis of traffic accident reconstruction with the use of output data of an event data recorder. This study is conducted double lane change test six times and slalom test one time as a field driving test and simulation. Based on the vehicle speed, the longitudinal and transverse acceleration, steering angle, driving path, and other kinds of information obtained from the field driving test, this study performed a simulation with PC-Crash program of reenacting and analyzing a traffic accident. The simulation was performed twice in the acceleration-steering angle input method and in the acceleration-driving path input method. By comparing the result of the field driving test with the results of the two simulations, we drew an analysis method with the optimal path reconstruction.

Planar Type Flexible Piezoelectric Thin Film Energy Harvester Using Laser Lift-off

  • Noh, Myoung-Sub;Kang, Min-Gyu;Yoon, Seok Jin;Kang, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.489.2-489.2
    • /
    • 2014
  • The planar type flexible piezoelectric energy harvesters (PEH) based on PbZr0.52Ti0.48O3 (PZT) thin films on the flexible substrates are demonstrated to convert mechanical energy to electrical energy. The planar type energy harvesters have been realized, which have an electrode pair on the PZT thin films. The PZT thin films were deposited on double side polished sapphire substrates using conventional RF-magnetron sputtering. The PZT thin films on the sapphire substrates were transferred by PDMS stamp with laser lift-off (LLO) process. KrF excimer laser (wavelength: 248nm) were used for the LLO process. The PDMS stamp was attached to the top of the PZT thin films and the excimer laser induced onto back side of the sapphire substrate to detach the thin films. The detached thin films on the PDMS stamp transferred to adhesive layer coated on the flexible polyimide substrate. Structural properties of the PZT thin films were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM). To measure piezoelectric power generation characteristics, Au/Cr inter digital electrode (IDE) was formed on the PZT thin films using the e-beam evaporation. The ferroelectric and piezoelectric properties were measured by a ferroelectric test system (Precision Premier-II) and piezoelectric force microscopy (PFM), respectively. The output signals of the flexible PEHs were evaluated by electrometer (6517A, Keithley). In the result, the transferred PZT thin films showed the ferroelectric and piezoelectric characteristics without electrical degradation and the fabricated flexible PEHs generated an AC-type output power electrical energy during periodically bending and releasing motion. We expect that the flexible PEHs based on laser transferred PZT thin film is able to be applied on self-powered electronic devices in wireless sensor networks technologies. Also, it has a lot of potential for high performance flexible piezoelectric energy harvester.

  • PDF

A Study on the Research Demands for the Pulse Analyzer (맥진기 연구개발에 대한 수요조사)

  • Kim, Gyeong-Cheol;Kim, Jong-Hwan;Shin, Woo-Jin;Lee, Hai-Woong;Kang, Hee-Jung
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.29-40
    • /
    • 2009
  • The demand of research for the development of pulse meter and analyzer by the examination questionnaire made from repeated preliminary investigations. Which was presented in the exhibition KIMES 2008, it's has been proved to be practical. 159 people(oriental medical doctor) sent in the question papers and selected the double answers in the relevant question. At the time of the development of the pulse meter and analyzer, we put the investigation for oriental medical doctor's demands in practice and found the following results. The development of the pulse analyzer is getting more important for modernization of oriental medicine. The purpose of this study was to find out the research needs for the pulse analyzer considering the practical use in the oriental medical clinics. A survey was conducted at the KIMES 2008 exhibition with a set of questionnaires. We collected the data from 159 oriental medical doctors who attended the exhibition, and we found following results. The more oriental doctors did not think the diagnostic devices were important in their clinical practices. Most responders preferred to use the Chon-Kwan-Cheok pulse diagnosis. To find out the mechanism of the pulse diagnosis and to standardize it, the clinical data base containing the results of the pulse diagnosis and the patten discrimination of each patient should be established. In conclusion, the researches on the standardization of Chon-Kwan-Chuk pulse diagnosis including the measurement techniques and the pulse-pattern correlations are very important for developing the pulse analyzer.

  • PDF