• Title/Summary/Keyword: Dose Constant

Search Result 262, Processing Time 0.031 seconds

Relationship between Tamoxifen and Sex Steroid Hormones on Uterus and Implantation in Rat (흰쥐 자궁 및 착상에 있어서 Tamoxifen과 성스테로이드 호르몬의 상호관계)

  • Han, H.J;Yoo, K.Y.;Kwun, J.K.;Yang, I.S.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.15 no.2
    • /
    • pp.93-102
    • /
    • 1988
  • These studies were undertaken to examine the relationship between tamoxifen and sex steroid hormones in rat uterine morphology and the effect of tamoxifen on sex steroid hormone levels, implantation and myometrial contraction. The results obtained were as follows : 1) The increase in height of the luminal epithelium caused by tamoxifen treatment was blocked by progesterone. The increase in height of luminal epithelium caused by $estradiol-17{\beta}$ treatment was blocked by tamoxifen. 2) When a single dose of tamoxifen(10, 20, $40{\mu}g$) was given on Day 2 of pregnancy, implantation was prevented. Plasma $estradiol-17{\beta}$ level fell in a dose-dependent manner but plasma progesterone level was constant. 3) In vitro, tamoxifen decreased rat uterine contractility in a dose-dependent manner.

  • PDF

Effect of Cimetidine Pretreatment on the Pharmacokinetics of Sulfisomidine Administered Intravenously in Rabbits (시메티딘이 설프이소미딘의 약물동태에 미치는 영향)

  • 이진환;최준식;범진필
    • YAKHAK HOEJI
    • /
    • v.29 no.6
    • /
    • pp.362-366
    • /
    • 1985
  • These paper was attempted to investigate the mechanism of increased blood level of sulfisomidine by cimetidine pretreatment pharmacokinetically. Especially, effect of cimetidine pretreatment on both renal clearance and biliary clearance of sulfisomidine was studied in rabbits. The results are as follows. The blood level of sulfisomidine administered intravenously in dose of 25mg/kg was elevated significantly by cimetidine pretreatment. Relative bioavailability and biological half-life were increased significantly by cimetidine pretreatment. Overall elimination rate constant ($betha$) and distribution rate constant ($K_{13}$) of sulfisomidine were decreased significantly by cimetidine pretreatment. The renal and biliary clearance of sulfisomidine were decreased significantly compared with those of control rabbits by cimetidine pretreatment. The results may be also related to the inhibition of sulfisomidine metabolism enzyme activity or reduction of blood flow in the liver.

  • PDF

Effect of Additives on the Radiation-Induced Grafting of Styrene onto Polypropylene Fabric (폴리프로필렌 부직포에 스틸렌의 방사선 그라프트 반응에서 첨가제의 영향)

  • Park, Jong Shin;Nho, Young Chang;Jin, Joon-Ha;Lee, Myun Zu
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.938-945
    • /
    • 1996
  • The present studies are to describe the grafting reaction of styrene in various solvents to polypropylene fabric by the simultaneous method using Co-60. The influence of various factors such as absorbed dose, dose rate, type of solvent, acid and multifunctional monomer were evaluated. At constant absorbed dose, the grafting yield was found to be higher at low dose rate. The initial rate of grafting was found to be proportional to a 0.56 power of dose rate. The inclusion of mineral acid in the grafting solution led to an increase in radiation grafting yield at almost all monomer concentration examined. Multifunctional monomer was also effective to increase grafting yield. The addition of both acid and multifunctional monomer was found to accelerate the grafting yield much more than the separate addition of two additives.

  • PDF

Effects of Se Pye San Water Extract on the Plasma Cortisol Concentration, Arterial Blood $PCO_2$ and $PO_2$ in the Rabbit (세폐산(洗肺散) 전탕액(煎湯液)이 가토(家兎).혈장(血漿) Cortisol 농도(濃度) 및 동맥혈(動脈血) $PCO_2,\;PO_2$에 미치는 영향(影響))

  • Kim, Dae-Won;Han, Sang-Hwan
    • The Journal of Internal Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.41-52
    • /
    • 1990
  • After intravenous administration of Se Pye San water extract in the rabbit, the change of plasma cortisol concentration, arterial blood $PCO_2$ and $PO_2$ was obtained such results as follows. 1. The plasma cortisol concentration in the control group was constant, but after intravenous administration of Se Pye San water extract at the dose of 0.2 ml/kg, the above concentration was increased significantly from 2 to 3 hours. Also, the above concentration was increased remarkably at the dose of 0.4 ml/kg from 1 to 4 hours. 2. After intravenous administration of Se Pye San water extract at each dose of 0.2 ml/kg and 0.4 ml/kg, arterial blood $PCO_2$ was decreased remarkably from 1 to 4 hours. 3. No change after intravenous administration of Se Pye San water extract at the dose of 0.2 ml/kg, while arterial blood $PO_2$ was decreased significantly at the dose of 0.4 ml/kg on 3 hours. As a results of the above, the therapeutic action of Se Pye San water extract effected with Jisu (止嗽), Jeong Cheon (定喘), Geo Dam, Cheong Yeol (淸熱) would be related with the increased both plasma cortisol concentration and arterial blood $PO_2$, and the decrease of arterial blood $PCO_2$.

  • PDF

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF

Proliferation of Dopamine $D_2$-Like Receptors after Treatment with Low Dose Haloperidol in Rat Brain (저용량의 Haloperidol투여에 의해 유발된 백서 뇌내 Dopamine $D_2$양 수용체증식)

  • Kim, Hwang-Jin;Hahn, Kyu-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.240-244
    • /
    • 1996
  • The effects of chronic treatment with haloperidol on the binding capacities of dopamine(DA) $D_2$-like receptor were investigated in rat striatum and olfactory tubercle. The authors tried to confirm the dose-response effects with usual dose and low dose haloperidol. Rats were treated with haloperidol(0.05, 0.15, 0.5, 1.5mg/kg/day in drinking water) for four weeks. Saturation analysis of the binding of [$^3H$]spiperone to striatal membranes showed that the haloperidol treatment(0.05, 0.5, 1.5mg/kg) induced significant proliferation. The changes of dissociation constant(Kd) were not significant in striatum. The maximal binding density(Bmax) and Kd increased remarkably following the treatment with usual dose haloperidol (1.5mg/kg) in olfactory tubercle. Although there was increasing trend other the treatment with low dose haloperidol, the change of Bmax was not significant statistically. The present findings indicate that low dose haloperidol induces the proliferation of DA $D_2$-like receptor in striatum and interact with the dopaminergic transmission which might underlie the antipsychotic effect. This finding may support the recent clinical suggestion on the low dose strategy in the treatment of schizophrenia.

  • PDF