• Title/Summary/Keyword: Domestic fire industry

Search Result 51, Processing Time 0.02 seconds

Fire Resistant Regulation Status and Activation Plan of Domestic Modular Construction (국내 모듈러 건축의 내화구조 제도 현황 및 활성화 방안)

  • Choi, Yun-Jeong;An, Jae-Hong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.673-680
    • /
    • 2022
  • Modular construction is recognized as a construction method with various advantages, such as shortening the construction duration, achieving quality control through factory production, ease of maintenance, and reduced construction costs due to reduced weight of materials. However, despite efforts by the modular industry and government to activate modular construction, it has rarely been established in the domestic market. Currently, there are technical limitations to the modular construction fire resisting technology applied to general buildings. The lack of access to modular construction fire resistance regulation is considered a major factor. In this study, the current status and problems with modular construction fire resistance regulation, a significant hindrance factor, were considered to activate modular construction. This study is intended to present a direction for institutional improvement in modular construction fire resistance and a direction for research and development.

A Study on the Classification Type Approval Certificate of Cruise Ship Equipment (크루즈선박 기자재의 선급형식승인에 관한 검토)

  • Kim, Ki-Pyoung;Kang, Ho-Keun;MA, Suk-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.250-253
    • /
    • 2011
  • The cruise industry is one of the world's fastest growing device industry which is structural construction coasts are expensive. Cruise out-fittings are thirty times compare with general large vessels. According to the characteristics of materials or equipments, most equipments are imported from europe. At present domestic shipbuilding industries and minor enterprises have a hard times therefore enhancing technology for the cruise industry could be infused vitality on the industries. If domestic small and midium industries have high technology for the cruise ship, domestic small and midium industries can have global competitiveness compare with european equipment suppliers which has small-scale and high technology. Therefore on this study, cruise ship's new equipment development and a study for the performance assessment and classification type approval certificate was carried out.

  • PDF

Analysis of Performance and Development of Environment-friendly High Expansion Foam Concentrate (친환경 고발포 소화약제 개발 및 성능 분석 연구)

  • Kim, Ha-Young;Nam, Jun-Seok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.25-29
    • /
    • 2010
  • Foam concentrate is used for fire-extinguishing purposes, occurring foam, mixed with air. In huge oil-fire or the efficiency of fire-extinguishing with small quantity of water, Foam concentrate is used widely. However, perfluorooc tanoicsulfonate and nonylpenol that are included in Foam concentrate could be exposure in danger while they were discharged. The purpose of the research is the development of environment-friendly high expansion foam that exclude the dangerous substances and improvement of danger of the existing foam concentrate. The developed foam is analyzed as the environment-friendly foam in indexes of the environment-toxicity, the biodegradation appraisal, and the dangerous substances-detecting. In addition, the performances of expansion rate, discharge rate, and fire-extinguishing are suitable in the domestic regulation, so it is useful for fire-extinguishing in real fire situation.

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1) (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1))

  • Han, Su-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

Study on the effective response method to reduce fire risk of wood fuel heating system (화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Bong-Woo;Lee, Guen-Cull;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.

Analysis of the Operation of Fire Observers in the Domestic Manufacturing Industry - Focusing on the Revised Occupational Safety and Health Act (국내 제조업 화재감시자 운영 실태 분석 - 개정 산업안전보건법 중심)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.77-84
    • /
    • 2023
  • Welding and cutting, which are representative tasks in handling firearms at industrial sites, are the basis for production and maintenance processes across all industries. They are also essential in the root industry. Specifically, they are widely used in the manufacturing industry, including equipment industries such as shipbuilding, automobiles, and chemicals, and subsequent maintenance work and general facility repair. However, such hot work carries a high fire risk owing to sparks scattering and inadequate management, resulting in a high occurrence of accidents. In response, the government and relevant organizations have recently revised the Occupational Safety and Health Act to prevent accidents during hot work. These revisions impose more stringent regulations than before, which are expected to help prevent actual fire accidents. However, whether the fire observer system, which is the core element of the revision, would be practically applied and maintained is unclear. Therefore, this study compared the fire observer system in the revised Occupational Safety and Health Act with those in the laws and systems of developed countries, conducted interviews with safety and health experts to assess the suitability of the new system for fire observer operations, and improvement plans were derived accordingly. Therefore, the laws and systems of developed countries grant more authority to fire observers compared with those of Korea. Moreover, professional training in handling emergency is required. Interviews with safety and health experts revealed that regardless of company size, the same operating standards were applied, and standards for deploying fire observers in various locations were unclear. Furthermore, there was a lack of professional education and training, and the role and authority of fire observers were limited. These findings revealed a problem in this sector. The results of this study are expected to serve as basic data for establishing a practical system for placing fire observers and supplementing laws, guidelines, and systems for preventing fire accidents.

Grand M Hotel interior renovation (포항 Grand M Hotel, 리노베이션 계획안)

  • Kim, Hye-Ja
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.97-98
    • /
    • 2006
  • This study proposes a method of generating steel house shop drawing in an automated design method, reducing construction manpower and period. With one hour fire-resistant approval code, reflecting work ability and efficiency, steel-framed house market is expected to extend from one or two story house to multi-purpose facilities up to four story height. More models have been constructed in this system than the first appearance of fire-resistant approval in Korea in 1997 Also, cost estimation of components such as frame walls, roof trusses and floors is obtained with shop drawings. Also, the lack of suppliers of steel framed house shop drawing and unstandardized drawing method get constructors have difficulty in understanding its design. In steel framed house industry, shop drawings are essential part in building and constructing framework and they have major effects on construction deadlines and expenses. By exploring method of shop drawing automation, this study aims to optimize work flow with a standardized drawing method. The proposed system can be applied to manufacturing automation in domestic industry of factory-built panelizing method in the near future.

  • PDF

An Evaluation of Flame and Fire Retardant Performance for Welding Blanket (용접 불티 차단막의 방염 및 난연성능 평가)

  • 이근원;권오승;하동명
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.53-58
    • /
    • 2001
  • This study was undertaken to evaluate the performance of flame retardant for fire precaution from sparks at welding-cutting process in industry sites such as shipbuilding yard and chemical factory. As the results of the performance experiment, six kinds of welding blanket in samples that are used commercially had enough in the performance of flame retardant. Nevertheless, the performance to fire precaution un welding blanket shows that the coaling product of two kinds with fiber glass is not sufficient. The lower oxygen index to welding blanket is considered that it is more than 30 in domestic standard. We suggested that the performance improvement of flame retardant for welding blanket need continuously, and the guideline of the flame retardant to welding blanket should be considered and established.

  • PDF

Study of the Problems and Improvements of the Installation and Maintenance for Natural Smoke Ventilators in Buildings (국내 배연창 설치 및 유지관리의 문제점과 개선방안에 관한 연구)

  • Yun, Hi-Won;Choi, Seung-Hyuck;Ryu, Hyung-Kyou
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.118-123
    • /
    • 2016
  • In the event of a building fire, it is important to control the smoke generated to ensure the safe evacuation of occupants. A natural smoke ventilator should be installed to exhaust the fire smoke in accordance with the Korean building Act and Code. On the other hand, the present law does not specify the contents regarding natural smoke ventilators sufficiently. The problems that occur in various parts, such as the installation target, installation location, free area, and the control and maintenance of natural smoke ventilators need to be solved. In this study, the problem of the current system was examined through domestic and foreign standards, preliminary research, and field investigations. In addition, suggestions for improvement are provided.