• 제목/요약/키워드: Distribution equipment

검색결과 1,068건 처리시간 0.029초

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험 (A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment)

  • 조진태;김주용;이학주;김재한
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

지역특성을 고려한 배전설비 고장률 산출에 관한 연구 (A Study on Failure Rate Extraction of Distribution System Equipment considering Regional Characteristics)

  • 최규완;채희석;문종필
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.199-203
    • /
    • 2016
  • The cost needed to managing equipment is constantly increasing because of increase of power equipment. The regulations such as PAS 55 and ISO 55000 were enacted to manage equipment assets. The advanced management methods such as real-time monitoring, condition evaluation, and health indices are avalable in generation system, transmission system, and substation transformers. However, These methods can not be applied to distribution equipment because of a lot of equipment. Therefore reliability assessment is very important in case of distribution equipment. In this paper, failure rates are extracted considering characteristics of regions, and which are the essential factors to reliability evaluation.

분산전원이 도입된 배전계통에 초전도전류제한기 적용에 따른 보호기기 동작분석 (Analysis on operation of Protective Equipment According to Application of SFCL in a Power Distribution System)

  • 이용석;정상현;임성훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.67-68
    • /
    • 2011
  • This paper analysed a protective equipment in power distribution system linked distribution power system when a superconducting fault current limiter(SFCL) is installed. This paper focused on a recloser, because the recloser is a general protective equipment. When power distribution system linked distribution power system, a fault current is increased by adding fault current of distribution power system. The increased fault current makes many problems. But SFCLs are limiting fault current and help the protective equipment to operate normal process. We analysed the operation of protective equipment in power distribution system linked distribution power system with SFCLs.

  • PDF

조선기자재 공동물류센터의 RFID 도입 방안 (A Strategy to Implement RFID in the Marine Equipment Distribution Center)

  • 강양석;최형림;김현수;홍순구;박재영
    • 한국IT서비스학회지
    • /
    • 제7권1호
    • /
    • pp.219-235
    • /
    • 2008
  • In this paper, we suggest a strategy to implement RFID in the Marine Equipment Distribution Center. Although RFID technology has be applied to the various business areas, due to the immature technological market and other reasons, for the successful RFID implementations, it is necessary for the company to review RFID implementations methodology. The aims of the Marine Equipment Distribution Center is to share storages for the marine equipment enterprises and to gain the max efficiency in the logistics flow. To achieve this goal RFID can be one of the alternatives. This paper suggests major issues that can help to reach the successful implementation of RFID in the distribution center.

신뢰도 평가를 위한 배전계통 설비기기 고장률 분석 (Power Distribution System Equipment Failure Rate Analysis for Reliability Estimation)

  • 이희태;김재철;문종필;박창호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.370-373
    • /
    • 2004
  • The inside and outside of the country utilities considered that they focused energy and economic aspect for short-term in new environment change of restructure. but it need service reliability preservation and improvement countermeasure, that is no to use existent estimation method for reliability preservation. therefore, analyze the equipment failure rate for suitable reliability preservation through equipment failure rate analysis of power distribution r system and evaluated equipment that is composing power distribution system by the failure rate. This paper estimated failure causes and the TVFR(Time Varying Failure Rate) for main equipment that is composing power distribution system using Weibull distribution.

  • PDF

Analyzing Government Support Program for R&D Collaboration and Distribution for Korean SMEs: A Case for Equipment Leasing Program

  • PARK, Mun-Su;CHANG, Soonwoo Daniel
    • 유통과학연구
    • /
    • 제20권12호
    • /
    • pp.99-108
    • /
    • 2022
  • Purpose: This study attempted to identify determinants affecting research collaboration and R&D distribution activities, especially regarding facility and equipment leasing of small and medium enterprises (SMEs) in South Korea. The objective of this study was to find the most significant firm characteristics that affect firms participating in an R&D collaboration and distribution program and investing in R&D in terms of leasing payment for equipment. Research design, data, and methodology: This study analyzes which SMEs' characteristics influence external research cooperation activities by examining the SMEs that received government support for equipment leasing using multiple regression analysis and residual plots. The survey combined two databases: 1) a fact-finding survey of participating firms by the Ministry of SMEs and Startups, and 2) leasing information by the Korea Association of University, Research Institute and Industry. Results: The study found that firm size positively impacts R&D investment, R&D collaboration and distribution. Conclusions: The study provided evidence to policymakers and government officials that firms with more employees will more likely participate in government support programs. The study results also prove that government officials believe firm location does not impact R&D investment, R&D collaboration and distribution.

소방공무원들이 인지하는 소방장비 보급으로 소방장비 만족도에 미치는 영향: 소방장비 신뢰성의 매개효과를 중심으로 (Influence on the Satisfaction of Fire Fighting Equipment by Distribution of Fire Fighting Equipment: Focusing on Mediating Effect of Reliability of Fire Fighting Equipment)

  • 이선범;김양현
    • 한국콘텐츠학회논문지
    • /
    • 제17권8호
    • /
    • pp.677-684
    • /
    • 2017
  • 본 연구는 소방장비의 발전을 위해 필요한 기초자료를 제공하기 위하여 소방공무원들이 인지한 소방장비 보급이 소방장비 만족도에 미치는 영향, 이 두변수 사이에서 소방장비 신뢰성의 매개효과를 검증하였다. 연구의 목적을 달성하기 위하여 경기도 7개 소방서의 소방공무원을 대상으로 설문을 실시하였다. 이렇게 수집된 자료는 AMOS 18.0을 사용하여 구조방정식모형을 통한 분석을 실시하였다. 주요한 연구결과는 다음과 같다. 첫째, 소방장비 보급량의 적절성과 보급의 적시성은 소방장비 신뢰성에 정(+)의 영향을 미치고 있었다. 둘째, 소방장비 신뢰성은 소방장비 만족도에 정(+)의 영향을 미치고 있었다. 셋째, 소방장비 보급량의 적절성은 소방장비 만족도에 정(+)의 영향을 미치고 있었다. 소방장비 신뢰성은 소방장비 보급량의 적절성과 소방장비 만족도와의 관계에 있어서 부분매개효과가 있다는 것을 알 수 있었다.

고효율기기의 수요측입찰 참여시의 비용-이익 분석 (Cost-Benefit Analysis on Participation of High Efficient Equipment in Demand-Side Bidding)

  • 원종률;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.396-400
    • /
    • 2005
  • This paper proposes the cost analysis on the energy efficient equipment when this equipment is participated in the demand-side bidding. Conventional demand-side bidding is exercised through load re-distribution. However if this load reduction is exercised by the use of high efficient equipment, its effect will be assumed to be more economical. This paper analyses this cost-benefit effect of high efficient equipment in the demand-side bidding.

회전형 CMP장비의 속도 및 마찰력 분포 해석 (Velocity and Friction Force Distribution in Rotary CMP Equipment)

  • 김형재;정해도;이응숙;신영재
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.39-39
    • /
    • 2003
  • As the design rules in semiconductor manufacturing process become more and more stringent, the higher degree of planarization of device surface is required for a following lithography process. Also, it is great challenge for chemical mechanical polishing to achieve global planarization of 12” wafer or beyond. To meet such requirements, it is essential to understand the CMP equipment and process itself. In this paper, authors suggest the velocity distribution on the wafer, direction of friction force and the uniformity of velocity distribution of conventional rotary CMP equipment in an analytical method for an intuitive understanding of variation of kinematic variables. To this end, a novel dimensionless variable defined as “kinematic number” is derived. Also, it is shown that the kinematic number could consistently express the velocity distribution and other kinematic characteristics of rotary CMP equipment.