Important Radionuclides and Their Sensitivity for Ground water Pathway of a Hypothetical Near-Surface Disposal Facility

  • Park, J. W.;K. Chang;Kim, C. L.
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.156-165
    • /
    • 2001
  • A radiological safety assessment was performed for a hypothetical near-surface radioactive waste repository as a simple screening calculation to identify important nuclides and to provide insights on the data needs for a successful demonstration of compliance. Individual effective doses were calculated for a conservative ground water pathway scenario considering well drilling near the site boundary. Sensitivity of resulting ingestion dose to input parameter values was also analyzed using Monte Carlo sampling. Considering peak dose rate and assessment time scale, C-14 and T-129 were identified as important nuclides and U-235 and U-238 as potentially important nuclides. For C-14, the dose was most sensitive to Darcy velocity in aquifer The distribution coefficient showed high degree of sensitivity for I-129 release.

  • PDF

고조파 저감형 하이브리드 변압기의 성능시험 (Performance Test and Design of Harmonic Reduction Hybrid Transformer)

  • 김지호;한성호;손진근
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.277-282
    • /
    • 2014
  • Hybrid transformer means the distribution transformer, one of multi-function transformer equipped with the enhancement function of harmonics and unbalance. In other words, since existing transformer are equipped simply with transformation function only, a separated electric facility should be additionally installed in order to reduce the mutual harmonics and unbalance. Meanwhile, since hybrid transformer can perform the reduction of harmonics and unbalance as well as transformation function simultaneously through zigzag winding, it doesn't need any additional electric facility. This study addressed the issue of developing and testing the performance of a generator that would reduce the harmonics supplied to the grid when grid-connected with the output of a photovoltaic inverter for photovoltaic generation system.

MASW FOR QUANTIFYING CHANGE IN SHEAR WAVE VELOCITY AFTER DEEP DYNAMIC COMPACTION AT A SOIL SITE

  • ChoonB.Park;RichardD.Miller
    • 지구물리
    • /
    • 제6권4호
    • /
    • pp.245-259
    • /
    • 2003
  • Two multichannel analysis of surface wave (MASW) surveys were conducted over a soil site in Tacoma Water's Green River Facility, Washington, where construction of a chemical treatment facility had been planned. The purpose of the surveys was to compare soil stiffness characterized by shear-velocity (Vs) distribution before and after Deep Dynamic Compaction (DDC) operation that was designed to improve the soil stiffness. Site soil consisted of very heterogeneous gravel and cobbles in a sand-and-silt matrix. Results from each survey are represented by two 2-D Vs maps delineating Vs variation of soil below the surveyed lines. One map was constructed from those dispersion curves that were analyzed with a significant amount of subjective judgment involved, whereas the other map was constructed from those dispersion curves analyzed with as much objective information as possible. Comparison of 2-D Vs maps indicates that Vs actually decreased after the DDC operations, possibly due to the loss (or reduction) of cohesive bonding between soil particles caused by the compaction operations.

  • PDF

2 Step 이상 운용 고객의 구내배전계통 지락보호시스템 구성 현황 및 문제점 검토 (A Study on Trouble and Arrangement of the Ground-Fault Protection for 2 Step Voltage Distribution System of Premises)

  • 임진성;신명호
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.73-77
    • /
    • 2010
  • Most accidents occurred in power receiving & transforming facility are ground fault. The quality of power supply is deteriorated since the ground fault is not detected promptly. This paper analyzes the problems about system-grounding type of 2 step power receiving & transforming facility, arrangement of protection relaying scheme and ground-fault protection system of ungrounded system. Then, this paper presents the arranging scheme of system-grounding type to improve power supply reliability.

농촌지역(農村地域)내 자연발생적(自然發生的) 생활편익시설(生活便益施設)의 이용특성(利用特性)에 관한 연구(硏究) (A Study on the Utilization of Community Facilities in Rural Areas)

  • 최명규
    • 한국농촌건축학회논문집
    • /
    • 제1권1호
    • /
    • pp.53-62
    • /
    • 1999
  • This study aims to draw out the planning data for the community facilities from architectural planning point of view. To achieve those aims, I attempted, in this paper, to analyze and evaluate the present level and characteristics of distribution and utilization, the degree of satisfaction in facilities, and desirable level of facility by users based on the classification of rural area. The result of this study will be expected to be a reference to the desirable facility planning for rural areas.

  • PDF

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

154kV 송전선로용 피뢰기 현장 설치 효과 분석 (A Study on the Effects of Lightning Arrestors Installment on a 154kV Transmission System)

  • 최한열;구성완;민병욱;박순규;이봉희;곽주식
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.184-189
    • /
    • 2009
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. As sensitive loads and reliance on electric power increase year by year, it is getting more focus on stable and high quality of power supply. To protect the transmission and distribution line from lightning, the transmission lightning arrester can be the effective facility on the power system. This paper discusses Gapped type Arresters application results by analysing effects of lightning arresters on transmission and distribution line.

154kV 송전선로용 피뢰기 현장 설치 효과 분석 (Study on the effects of lightning arrestors installment on a 154kV transmission system)

  • 최한열;민병욱;박순규;이봉희;곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.9-11
    • /
    • 2008
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. To protect the transmission and distribution line from lightning, the transmission lightning arrestor can be the effective facility on the power system. This paper will discuss Gapped type Arresters application results by analysing effects of lightning arrestors on transmission and distribution line.

  • PDF

탄소제로 빌딩을 위한 전력변환 제어 (Power conversion control for zero emission buildings)

  • 한석우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

전력설비 안전성 확보를 위한 GIS(가스절연개폐장치) 검사수행 절차 및 방법 (The Inspection Procedure and Method of GIS to Guarantee the Safety of Power Facility)

  • 박준성;황광수;김진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.361-364
    • /
    • 2015
  • 본 논문은 전기사업법 제61조의 공사계획인가 및 신고대상인 차단기에 대하여 동법 제63조에 의거해 실시하는 사용전검사의 항목 및 검사수행 방법에 대하여 서술하였다. 차단기는 전력계통을 이상전압에서 보호하기 위한 밀폐형 개폐장치로서 전기사업용 전기설비인 변전소에 설치되는 차단기는 대부분 GIS(Gas Insulated Switchgear)화 되고 있는 실정이다. GIS는 정상전류의 차단, 설비사고의 억제 및 파급사고 확산방지에 중추적인 역할을 수행하고 있기 때문에 그 중요성은 더욱 더 높아지고 있다고 볼 수 있다. 이에 핵심 전력설비인 GIS의 사용전 검사항목 및 검사수행 방법을 고찰함으로써 안정적인 전력공급과 전력계통의 신뢰도 제고에 기여하고자 한다.