An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques (PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정)

  • Park, Cheol-Woo;Baek, In-Je
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

Investigation of Cooling Effect of Flow Velocity and Cooler Location in Thermal Nanoimprint Lithography

  • Lee, Woo-Young;Lee, Ki Yeon;Kim, Kug Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.37-42
    • /
    • 2012
  • Nanoimprint lithography (NIL) has attracted broad interest as a low cost method to define nanometer scale patterns in recent years. A major disadvantage of thermal NIL is the thermal cycle, that is, heating over glass transition temperature and then cooling below it, which requires a significant amount of processing time and limits the throughput. One of the methods to overcome this disadvantage is to improve the cooling performance in NIL process. In this paper, the performance of the cooling system of thermal NIL is numerically investigated by SolidWorks Flow Simulation program. The calculated temperatures of nanoimprint device were verified by the measurements. By using the analysis model, the effects of the change of flow velocity and cooler location on the cooling performance are investigated. For the 6 cases (0.1 m/s, 0.5 m/s, 1 m/s, 3 m/s, 5 m/s, 10 m/s) of flow velocity and for the 6 cases of distances (50 mm, 40 mm, 30 mm, 20 mm, 10 mm, 1 mm) of cooler location, the heat conjugated flow analyses are performed and discussed.

Development of a Sensor Calibration to Enhance the Performance of a Non-contact Laser Optical Sensor Unit (비접촉 레이저 광센서의 성능 향상을 위한 센서보정에 관한 연구)

  • Seo, Pyeong-Won;Ryu, Young-Kee;Oh, Choon-Suk;Byun, Jong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.579-581
    • /
    • 2006
  • Flat panel image display devices such as TFT LCD and PDP have required more large area and high quality control components. To control the qualities of the components, measurements of the flatness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens. The temperature of the sensor body is controlled by TEC(Thermoelectric Cooler) to maintain the same wavelength of the diode laser. In this research, we proposed the calibration scheme to make sensor real time measuring sensor. From the experimental results we see that the proposed sensor unit can measure the position of the glass surface in rial time.

  • PDF

A Study on Measuring the Shape of Transparent Objects using the Focal Area of Hologram Optical System (홀로그램 광학계의 초점영역을 이용한 투명 물체의 형상 측정에 관한 연구)

  • Byun, Jong-Hwan;Ryu, Young-Kee;Oh, Choon-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.600-602
    • /
    • 2005
  • Recently image display devices have become large and high quality. To control the qualities of the component, measurements of the shape and thickness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens used for CD Player, and the sensor showed high performance for measuring the shape and thickness of transparent plates. In the sensor, the temperature of the sensor body is controlled by TEC(Thermoelectric Cooler). In this paper, we proposed the measuring method to make better performance of sensor using focus error signal of a hologram laser unit. It can measure the shape and the thickness of transparent objects with the s-type focus error signal which is generated by the sensor while it goes to the object.

  • PDF

The effect of color on apparent warmth and judgment distortion (색의 속성에 따른 지각된 온도감과 판단 왜곡)

  • Kim, Moon-Ju;Han, Kwang-Hee;Lee, Ju-Hwan
    • Science of Emotion and Sensibility
    • /
    • v.9 no.4
    • /
    • pp.341-351
    • /
    • 2006
  • The effect of color evokes a certain feeling and affects behavior. Especially, an understanding and applying color are critical because well-designed color substantially contributes to quality and usability. In this study, the effects of three color components(hue, value, and chroma) on apparent warmth were investigated separately and relatively, and then feasibility of applying to the information display was examined. The result showed that the apparent warmth of 10 Hues was a U-shaped function declining from Red to Purple-Blue and increasing from Purple-Blue to Red-Purple with following order of color-circle. Chroma made the character of hues remarkably clear, so warm color becomes warmer and cool color becomes cooler if chroma gets higher. But value has no effect on warmth. These results propose that we can change the apparent warmth by varying chroma in the limitation of color use. And there was a sharp distinction between warm and cool color, Meanwhile, in the reading task of the graphical information, the subjects' judgment distortion overestimating or underestimating the actual degrees was ascertained. This result should be applied to control operator's sensitivity in accordance with the purpose of task and display.

  • PDF

A Study on the Fluoro-polymer Composite Coatings for Protecting the Corrosion of Fossil-fuel Power Plants

  • Kang, Min Soo;Lee, Byung Seung;Chang, Hyun Young;Jin, Tae Eun;So, Il Soo
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2007
  • Several heavy duty coatings at an every kind industry facilities to various systems currently have been applied review to the many industry fields. Corrosion-protective characteristics in the case of novolac epoxy among them and unsaturated polyester have been applied most widely. epoxy and flake heavy duty coatings are applied for such reason in an every kind facilities(stack, FGD, cooler, chemical tank etc) of a fossil-fuel power plants Cases of the fossil-fuel power plants are exposed to more severe corrosion environment compared with other facilities and It is difficult to display the performance of long-term method at apply to be the partial. Our study shows fluoro-polymer composite coating method to overcome of the limit. The comparison did previous method and heavy duty coating about FGD plants most at a corrosion environment among fossil-fuel power plants. Additionally, other facilities examined different heavy duty method. The design mode of fluoro-polymer composite coating according to an every kind facilities show extensive methods that are characteristic revelation of film(top, middle and primer layer) composition of the paint, film thickness in accordance with a facilities corrosion and the corrosion protective effectiveness to come into being use fluoro-polymer composite with heavy duty paint(epoxy).

Advanced LWIR Thermal Imaging Sight Design (원적외선 2세대 열상조준경의 설계)

  • Hong, Seok-Min;Kim, Hyun-Sook;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.209-216
    • /
    • 2005
  • A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.