Browse > Article
http://dx.doi.org/10.3807/KJOP.2005.16.3.209

Advanced LWIR Thermal Imaging Sight Design  

Hong, Seok-Min (Agency for Defence Development)
Kim, Hyun-Sook (Agency for Defence Development)
Park, Yong-Chan (Agency for Defence Development)
Publication Information
Korean Journal of Optics and Photonics / v.16, no.3, 2005 , pp. 209-216 More about this Journal
Abstract
A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.
Keywords
Lens design; Digital image processing; Image detection systems;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 G. Gaussorgues, Infrared Thermography, Chapman & Hall, London, pp.1-60, 1994
2 J. L. Miller, Principles of lnfrared Technology, Van Nostrand Reinhold, New York, pp. 3-51, 1994
3 김창우, 김현숙, 홍석민, 김재기, '열상장비용 직병렬 주사광학계,' 한국광학회지, vol. 5, no. 2, pp. 212-216, 1994
4 홍석민외, '직병렬 주사방식 열상장비의 설계 및 제작,' 응용물리, 제8권, 제3호, pp. 289-295, 1995
5 H. S. Kim et aI., 'Compact MWIR camera with $\times$20 zoom optics,' Proc. SPIE 4369, 673-679, 2001   DOI
6 R. E. Fischer, B. Tadic-Galeb, Optical system design, McGraw-Hill, New York, 2000
7 W. K. Yu, et aI., 'Digital image processing for thermal observation system,' Proc. SPIE 2513, 590-595, 1995   DOI
8 R. Simmons, 'Athermalisation of a fast infrared telescope objective', Proc. SPIE 2539, 137-149, 1995   DOI
9 H. S. Kim, C. W. Kim, and S. M. Hong, 'Compact mid-wavelength infrared zoom camera with 20:1 zoom range and automatic athermalization,' Optical Engineering, vol. 41(7), 1661-1667, 2002   DOI   ScienceOn
10 홍석민외, '320$\times$240 적외선 검출기를 이용한 열상센서 설계,' 한국광학회지, vol. 15, no. 5, pp. 423-428, 2004
11 A. Mann, Infrared optics and zoom lenses, SPIE Press, chap.3, p.28-30, SPIE Press, 1996
12 M. J. Riedl, Optical design fundamenrals for Infrared systems, SPIE press, 1995
13 M. Broekaert and Bruno Noel du Payrat, 'Nonlinearity & non-uniformity corrections for IRIS family of IRCCD thermal imagers,' Proc. SPIE 2269, 507-523, 1994   DOI
14 Virgil E. Vickers, 'Plateau equalization algorithm for realtime display of high-quality infrared imagery,' Optical Engineering, vol. 35(7), 1921-1926, 1996   DOI   ScienceOn