• Title/Summary/Keyword: Displacement measuring system

Search Result 264, Processing Time 0.033 seconds

Measurement of Dynamic Characteristics on Structure using Non-marker Vision-based Displacement Measurement System (비마커 영상기반 변위계측 시스템을 이용한 구조물의 동특성 측정)

  • Choi, Insub;Kim, JunHee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.301-308
    • /
    • 2016
  • In this study, a novel method referred as non-marker vision-based displacement measuring system(NVDMS) was introduced in order to measure the displacement of structure. There are two distinct differences between proposed NVDMS and existing vision-based displacement measuring system(VDMS). First, the NVDMS extracts the pixel coordinates of the structure using a feature point not a marker. Second, in the NVDMS, the scaling factor in order to convert the coordinates of a feature points from pixel value to physical value can be calculated by using the external conditions between the camera and the structure, which are distance, angle, and focal length, while the scaling factor for VDMS can be calculated by using the geometry of marker. The free vibration test using the three-stories scale model was conducted in order to analyze the reliability of the displacement data obtained from the NVDMS by comparing the reference data obtained from laser displacement sensor(LDS), and the measurement of dynamic characteristics was proceed using the displacement data. The NVDMS can accurately measure the dynamic displacement of the structure without the marker, and the high reliability of the dynamic characteristics obtained from the NVDMS are secured.

Control and data analysis of a measuring machine for cams (캠 형상 전용 측정기 제어 및 해석 S/W 개발)

  • 최동우;강재관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.150-153
    • /
    • 1997
  • In this paper, a control and data analysis S/W of a dedicated measuring machine for cams is developed. A rotary encoder is employed to measure the angular displacement of the motor, and a linear scale does the linear displacement of the prove. The design and measuring data are interpolated by cubic spline curves respectively to compute the error which is defined by the maximum distance between two curves. Further, optimization module to find the exact error is also developed to remove the error occurred due initial measuring position. The developed system takes only 6 minutes to measure the cam and to analyze the measuring data while the CMM takes about 1 hours even with a skilled operator.

  • PDF

Non-contacting OMM (On Machine Measurement) based on CAD Model (CAD 모델 기반 비접촉 기상 측정에 관한 연구)

  • 권세진;이정근;박정환;고태조;김선호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.134-141
    • /
    • 2003
  • An industrial product is designed and fabricated, followed by the inspection process in order to check whether it is dimensionally tolerable or not. The machining process produces a part such as a mold or die, in which the three-dimensional coordinate might be measured by a CMM (Coordinate Measuring Machine) for assessment of its dimension. It is not ignorable, however, that a CMM measurement requires a lot of operating time and cost, which has led to many studies on the OMM system. The OMM system can be categorized into contact and non-contact types, and each of which has its own strengths and weaknesses. Non-contacting types generally utilize structured lights, sounds or magnetic fields. Though they show rather poor performance in positional accuracy, the measuring speed is faster than the contacting probes. This paper presents the development of an OMM system based on a non-contacting laser displacement sensing apparatus and CAD model. The system is composed of software modules of center-aligning and measuring, which has been operated and verified on a NC machining center on a shop floor.

A Study on the Vibrational Reduction Evaluation and the Relative Displacement in the External Vibration of Precision Measuring System (초정밀 측정/가공 장비의 외부진동에 대한 상대변위의 추출과 진동성능 평가에 관한 연구)

  • 전종균;엄호성;김강부;원영재
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.1
    • /
    • pp.65-72
    • /
    • 2002
  • Generally, there are laser operating equipments( aligner, stepper) and electronic microscope( SEM, TEM) as a high precision manufacturing and inspection equipment in semiconductor production companies, precision examination and measuring laboratories. Mostly, these equipments are characterized by projection and target part. The relative displacements between projection and target part are dominant roles in vibrational problem in these precision equipments. These relative displacements are determined by the position of incoming vibration and the difference of vibration response in projection and target part. In this study, the allowable vibrational limits are suggested and the vibrational reduction plans are proposed by measurement and analysis of vibration phenomenon in the Clean Room in PDP(plasma display panel) production building. The vibration performance is evaluated by comparison relative displacements between projection and target part before/after the vibration isolation plan.

Angular Displacement Measurement Using Optical Sensor (광학센서를 이용한 관절운동각도 측정)

  • Jung, Gu-In;Kim, Ji-Sun;Hur, Dong-Hun;Yu, Hwan-Dong;Lim, Sung-Hwan;Choi, Ju-Hyeon;Lee, Jeong-Hwan;Eom, Gwang-Moon;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1959-1965
    • /
    • 2011
  • Measuring the movement of joint angle of human body is very important clinically. Human joint angle displacement can be used to evaluate the degree of disease and disability. Also, we can determine the rehabilitation process with angular information. Conventional methods for measuring angular displacement are many weakness. The purpose of this study is to overcome the limitations of existing equipments by using optical method. For this reason, optical sensor system was used to correlate detected light signal with joint angle. Experimental results of the applied joint model in this study showed that joint angular displacement can be measured by optical signals. The suggested method is simple, durable, small, lightweight, convenient, and cost effective.

Image Processing Technique for Measuring the Static Displacement of Bridges from General Inspection Photograph (일반 점검사진에서 교량의 정적 변위 추출을 위한 영상처리기법)

  • Cho, Jun Sang;Huh, Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.173-180
    • /
    • 2011
  • This paper aims to propose an image processing technique for measuring the static displacement of bridges from general inspection photograph; the color, shape, and spatial transformations of an arbitrary image stored in bridge management system database are used. This study is verified by using numerical analyses with experiments; the results demonstrate that the static displacement of bridges are measured by proposed technique. Moreover, this technique is able to obtain the static structural response of the bridge with changes in temperatures.

A Study on the Electrical Properties of Biology Thin (생체박막의 전기특성에 관한 연구)

  • 오재한;김동관;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.243-246
    • /
    • 1999
  • The displacement current measuring system used for detecting the dynamic behavior of monolayers at the air-water interface is described. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is the water, With Maxwll-displacement-current-measuring method, the phase transitions of Poly(λ-benzyl- L-glutamate)(PBLG) on a water surface were detected, Displacement currents generated during the compression of monolayers of PBLG on the surface of water were investigated. As results, the displacement pick was generated when the area per molecule was about 15 $\AA$$^{2}$ in low pressure, and tit was generarted when the area per molecule about 27$\AA$$^{2}$ in high pressure.

  • PDF

The Error Source Analysis of Measuring Data of OMM System (OMM 시스템의 측정오차 원인분석 및 대책)

  • 이상준;김선호;김옥현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.73-77
    • /
    • 1997
  • This paper describes the analysis of measuring error of on the machine measuring(OMM) system which can directly measure the three dimensional machined free surface dimension using scanning probe on milling machine. 21 inch TV shadow mask mould was measured using PTP(point to point)measurement algorithm at pallet clamped and unclamped state on OMM system, and using coordinate measuring machine(CMM) one after another. The OMM system was evaluated probe error, stylus contact error, center shift error, repeatability and so on. Consequencely, the conclusion derived that elastic displacement of pallet had effect on measuring error mainly, and pallet design and setup method would be important.

  • PDF

Prediction of Strain Responses from Displacement Response Measurements (변위응답의 측정으로부터 변형률응답의 예측)

  • 이건명;신봉인;이한희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1384-1387
    • /
    • 2001
  • Presented is a method to predict strain responses from displacement measurements on a mechanical structure. The method consists of forming a transformation matrix, which is calculated from displacement and strain modal matrices. The modal matrices can be obtained by either finite element analysis or modal testing. One disadvantage of the method is that it requires displacements on all measuring points be measured simultaneously. The strain prediction method is applied to a simple simulated system.

  • PDF

Development and application of a vision-based displacement measurement system for structural health monitoring of civil structures

  • Lee, Jong Jae;Fukuda, Yoshio;Shinozuka, Masanobu;Cho, Soojin;Yun, Chung-Bang
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.373-384
    • /
    • 2007
  • For structural health monitoring (SHM) of civil infrastructures, displacement is a good descriptor of the structural behavior under all the potential disturbances. However, it is not easy to measure displacement of civil infrastructures, since the conventional sensors need a reference point, and inaccessibility to the reference point is sometimes caused by the geographic conditions, such as a highway or river under a bridge, which makes installation of measuring devices time-consuming and costly, if not impossible. To resolve this issue, a visionbased real-time displacement measurement system using digital image processing techniques is developed. The effectiveness of the proposed system was verified by comparing the load carrying capacities of a steel-plate girder bridge obtained from the conventional sensor and the present system. Further, to simultaneously measure multiple points, a synchronized vision-based system is developed using master/slave system with wireless data communication. For the purpose of verification, the measured displacement by a synchronized vision-based system was compared with the data measured by conventional contact-type sensors, linear variable differential transformers (LVDT) from a laboratory test.