• Title/Summary/Keyword: Discharging process

Search Result 188, Processing Time 0.025 seconds

A Research about Implementation of Fuzzy Control Algorithm with Variable Input Gain for Improving Performance of Tension Control (장력제어 성능개선을 위한 가변 입력이득 퍼지제어알고리즘 적용에 관한 연구)

  • Sul, Jae-Hoon;Park, Jong-Oh;Jang, Jong-Seung;Lim, Young-Do
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.8
    • /
    • pp.680-688
    • /
    • 2001
  • In this paper, the fuzzy control with variable input gain is applied to maintain the consistent tension in the process of taking up and releasing texture. In the process of discharging web on one side rolling it on another, the take-up drum gets smaller on the release drum side as it gets bigger on the rolling side, thus it is necessary to change the balance of velocity between the sides. In order to solve the problem a tension controller is necessary. The PI control method has been employed to maintain the consistent tension, but the PI control method produces a problem which requires an experienced worker with the traits of the machine, in order to perform the fine adjustments according to the environment of the process. For solving the above problem, we apply fuzzy control to the tension system, in order to produce a uniform roll. For the performance test, the fuzzy controller does not need to revise the parameters. Therefore the fuzzy controller exhibits an excellent additivity for the tension system where the system is changed with time.

  • PDF

Synthesis and Characteristics of LiCoO2 Powders Prepared by SHS Process (자전연소합성법을 이용한 리튬이차전지용 양극활물질 LiCoO2의 제조 및 특성)

  • ;;;Hayk H. Nersisyan
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.5
    • /
    • pp.388-394
    • /
    • 2004
  • LiCoO$_2$ as the cathode activity material for lithium secondary battery was prepared from a homogeneously mixed powder of LiNO$_3$/Co by SHS process under argon gas. The characteristics of powder including electrochemical properties were investigated according to various reaction conditions. The reaction temperature/velocity and the size of LiCoO$_2$ were controlled by Li/Co molar ratio and a cooling rate of the specimen, respectively. The maximum discharge capacity was 145 mAh/g on 1.05 Li/Co molar ratio and the relatively stable cycling characteristic with 6.4% of capacity fading was obtained after 10th charging-discharging test.

SOC Estimation of Flooded Lead Acid Battery Using an Adaptive Unscented Kalman Filter (적응형 Unscented 칼만필터를 이용한 플러디드 납축전지의 SOC 추정)

  • Khan, Abdul Basit;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.59-60
    • /
    • 2016
  • Flooded lead acid batteries are still very popular in the industry because of their low cost as compared to their counterparts. State of Charge (SOC) estimation is of great importance for a flooded lead acid battery to ensure its safe working and to prevent it from over-charging or over-discharging. Different types of Kalman Filters are widely used for SOC estimation of batteries. The values of process and measurement noise covariance of a filter are usually calculated by trial and error method and taken as constant throughout the estimation process. While in practical cases, these values can vary as well depending upon the dynamics of the system. Therefore an Adaptive Unscented Kalman Filter (AUKF) is introduced in which the values of the process and measurement noise covariance are updated in each iteration based on the residual system error. A comparison of traditional and Adaptive Unscented Kalman Filter is presented in the paper. The results show that SOC estimation error by the proposed method is further reduced by 3 % as compared to traditional Unscented Kalman Filter.

  • PDF

Knowledge-Based Loading/Discharging Monitoring System for a Crude Oil lanker (지식기반 유조선 안전 적ㆍ양하 모니터링 시스템)

  • Lee Kyung Ho;Park Jin Hyung;Lee Hee Yong;Seo Sang Hyun;Kwon Byung Kon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.4
    • /
    • pp.61-69
    • /
    • 2001
  • Recently, according to the rapid development of computer and electronic technology, most crude oil carriers adopt automated cargo handling system. But an excessive automation makes system so complicate that it could increase the Possibility of accidents due to human error. Although a cargo handling process is done by an expert, the potential of accidents by human factor lies through the whole cargo handling procedure and the current automated system lacks of the functionality to prevent a mis-operation and diagnose the abnormal status of the system. Because the oil concerned accident could be almost a disaster, the primary goal of system development should not be a fully automated system but be a perfectly safe system. This paper deals with the analysis and design of an expert system which can provide mariner with the operational guidance and the facility of crisis management by monitoring system's abnormal condition and human's mis-operation.

  • PDF

An Experimental Study on the Damage of the Data Process Equipment When $CO_2$ is Discharged ($CO_2$ 소화설비 방사시 정보저장장치의 저온손상에 관한 연구)

  • 이수경;김종훈;김영진;최종운
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.19-26
    • /
    • 1999
  • $CO_2$ extinguishing system is the most $\phi$pular among the gas extinguishing system. $CO_2$ is usually stored with liquified state. But, it gasifies at the tip of nozzle when $CO_2$ was released through the pipe and head. A ro$\alpha$n temperature is very low when $CO_2$ was released. So electrical instrument, magnetic storage equipment and memory semiconductor are electrically or physically injured by cooling effect in a few minutes. So, we intend to find out temperature profile and electrical damage in compartment area, and supply basic d data for research and making standards and code through the full scale experiment. As result of experiment on the damage due to cooling effect from $CO_2$ extinguishing system, i instantaneous discharging temperature. was $-82.5^{\circ}C$ in average. An average temp. in the compartment after discharging $CO_2$ was $-40^{\circ}C$.

  • PDF

A Numerical Investigation of Hydrogen Desorption Reaction for Tritium Delivery from Tritium Storage Based on ZrCo (ZrCo 기반 저장용기로부터 삼중수소 공급을 위한 수소 방출에 대한 수치해석적 연구 (II))

  • Yoo, Haneul;Jo, Arae;Gwak, Geonhui;Yun, Seihun;Chang, Minho;Kang, Hyungoo;Ju, Hyunchul
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.1
    • /
    • pp.36-43
    • /
    • 2013
  • In this paper, a three-dimensional hydrogen desorption model is applied to a thin double-layered annulus ZrCo hydride bed and validated against the temperature evolution data measured by Kang et al. The present model reasonably captures the bed temperature evolution behavior and the 90% hydrogen discharging time. In addition, the performance of thin double-layered annulus bed is evaluated by comparing with a simple cylindrical bed using hydrogen desorption model. This study provides multi-dimensional contours such as temperature and H/M atomic ratio in the metal hydride region. This numerical study provides fundamental understanding during hydrogen desorption process and indicates that efficient design of the metal hydride bed is critical to achieve rapid hydrogen discharging performance. The present three-dimensional hydrogen desorption model is a useful tool for the optimization of bed design and operating conditions.

A Study on the Characteristic of Heat Transfer of PCM(Phase Change Material) at the Simultaneous Charging and Discharging Condition (동시 축·방열 조건에서 PCM의 열전달 특성에 관한 연구)

  • Lee, Donggyu;Park, Sechang;Chung, Dong-yeol;Kang, Cheadong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.305-310
    • /
    • 2016
  • A thermal storage systems was designed to correspond to the temporal or quantitative variation in the thermal energy demand, and most of its heat is stored using the latent and sensible heat of the heat storage material. The heat storage method using latent heat has a very complex phenomenon for heat transfer and thermal behavior because it is accompanied by a phase change in the course of heating/cooling of the heat storage material. Therefore, many studies have been conducted to produce an experimentally accessible as well as numerical approach to confirm the heat transfer and thermal behavior of phase change materials. The purpose of this study was to investigate the problems encountered during the actual heat transfer from an internal storage tank through simulation of the process of storing and utilizing thermal energy from the thermal storage tank containing charged PCM. This study used analysis methods to investigate the heat transfer characteristics of the PCM with simultaneous heating/cooling conditions in the rectangular space simulating the thermal storage tank. A numerical analysis was carried out in a state considering natural convection using the ANSYS FLUENT(R) program. The result indicates that the slope of the liquid-solid interface in the analysis field changed according to the temperature difference between the heating surface and cooling surface.

Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules (스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구)

  • Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.

Preparation and Characterization of Carbon Nanotubes-Based Composite Electrodes for Electric Double Layer Capacitors

  • Seo, Min-Kang;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1523-1526
    • /
    • 2012
  • In this work, we prepared activated multi-walled carbon nanotubes/polyacrylonitrile (A-MWCNTs/C) composites by film casting and activation method. Electrochemical properties of the composites were investigated in terms of serving as MWCNTs-based electrode materials for electric double layer capacitors (EDLCs). As a result, the A-MWCNTs/C composites had much higher BET specific surface area, and pore volume, and lower volume ratio of micropores than those of pristine MWCNTs/PAN ones. Furthermore, some functional groups were added on the surface of the A-MWCNTs/C composites. The specific capacitance of the A-MWCNTs/C composites was more than 4.5 times that of the pristine ones at 0.1 V discharging voltage owing to the changes of the structure and surface characteristics of the MWCNTs by activation process.

The development of auto Ballast Water Management Plan For Bulk Carrier. (BULK선용 자동 Ballast Water Management Plan 개발)

  • Hong, Chung-You;Kwon, Young-Sub;Kwon, Sung-Jin;Hwang, Jin-Wook;Park, Je-Woong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.266-271
    • /
    • 2003
  • Many port states such as New Zealand. the USA. Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organism and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason. they perceived that the ballast exchange in deep sea is the most effective method. together with submitting the ballast management plan which contains the effective exchange method. ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that. it provide more convenient and stable process to prepare ballast water management plan for Bulk Carrier.

  • PDF