• Title/Summary/Keyword: Discharge tester

Search Result 44, Processing Time 0.021 seconds

Human body model electrostatic discharge tester using metal oxide semiconductor-controlled thyristors

  • Dong Yun Jung;Kun Sik Park;Sang In Kim;Sungkyu Kwon;Doo Hyung Cho;Hyun Gyu Jang;Jongil Won;Jong-Won Lim
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.543-550
    • /
    • 2023
  • Electrostatic discharge (ESD) testing for human body model tests is an essential part of the reliability evaluation of electronic/electrical devices and components. However, global environmental concerns have called for the need to replace the mercury-wetted relay switches, which have been used in ESD testers. Therefore, herein, we propose an ESD tester using metal oxide semiconductor-controlled thyristor (MCT) devices with a significantly higher rising rate of anode current (di/dt) characteristics. These MCTs, which have a breakdown voltage beyond 3000 V, were developed through an in-house foundry. As a replacement for the existing mercury relays, the proposed ESD tester with the developed MCT satisfies all the requirements stipulated in the JS-001 standard for conditions at or below 2000 V. Moreover, unlike traditional relays, the proposed ESD tester does not generate resonance; therefore, no additional circuitry is required for resonant removal. To the best of our knowledge, the proposed ESD tester is the first study to meet the JS-001 specification by applying a new switch instead of an existing mercury-wetted relay.

A Study on the Design and Implementation of Charge and Discharge-Tester for Capacitors (콘덴서 양부판정용 충·방전 시험기 설계와 구현에 관한 연구)

  • Moon, Jong-Hyun;Kim, Geum-Soo;Park, Jae-Wook;Seo, Chul-Sik;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.71-78
    • /
    • 2010
  • The existing capacitor-testers could only judge the condition of capacitor is normal or abnormal, and could not inform the real characteristics of the tested capacitors. In this research, it has designed the real-time observation of the new capacitor in charge and discharge tester for showing capacitor conditions and classification through wide voltages by regular cycle-tests. And proposed the quality classification algorithm of capacitors for more simple and practical, and approve them by test.

Development of Charger/Discharger to Test Performance for EDLC (EDLC를 위한 성능시험용 충방전기 개발)

  • Kim, Geum-Soo;Moon, Jong-Hyun;Cho, Hyun-Cheol;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.16-22
    • /
    • 2012
  • With the increase of consumption of new renewable energy, the use of Electric Double Layer Capacitor(EDLC) is being gradually widened as the next generation energy storage device. In order to expand the market of EDLC which is recently receiving a lot of attraction as a new promising area, development of a charge/discharge cycle tester to measure and test performance, is essential. Therefore, this research designed a circuit to measure capacity and internal resistance and a circuit to measure voltage maintenance properties, based on EDLC's basic charging/discharging properties so it is able to measure the state of charge and discharge at high speed. When evaluating performance characteristics, the 5[V]/100[A] prototype-EDLC charge/discharge testing system developed for this research showed ${\pm}0.1$[%] of accuracy of voltage and current measurement. It was also proved that the developed charge/discharge testing system for EDLC can be applied to the actual industry, when testing the entire system using a program produced for data monitoring and acquisition.

A Study on the TiC Coating Using Hollow Cathode Discharge Ion Plating (HCD이온플레이팅 방법을 이용한 zzTiC코팅에 관한 연구)

  • 김인철;서용운;황기웅
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.875-882
    • /
    • 1992
  • Titanium carbide(TiC) films, known as having excellent characteristics of resistance to wear and corrosion, were deposited on SUS-304 sheets using HCD(Hollow Cathode Discharge) reactive ion plating with acetylene gas as the reactant gas. The characteristics of TiC films were examined by X-ray diffraction, micro-Vickers hardness tester, ${\alpha}$-step, SEM(Scanning Electron Spectroscopy), ESCA(Electron Spectroscopy for Chemical Analysis), and AES(Auger Electron Spectroscopy) and the results were discussed with regard to the changes of various deposition conditions(bias voltage, acetylene flow rate, temperature).

HBM ESD Tester for On-wafer Test using Flyback Method (Flyback 방식을 이용한 on-wafer용 HBM ESD 테스터 구현)

  • 박창근;염기수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1079-1083
    • /
    • 2002
  • We made ESD tester to measure ESD threshold voltage of semiconductor devices. The HBM ESD test is the most popular method to measure the ESD threshold voltage of MMSIC. We use flyback method which is one of the DC-DC converter to get high ESD voltage. With flvback method, we can isolate the 1ow voltage part from the high voltage part of HBM ESD tester. We use an air gap of the relay which is used for switch to satisfy the rise time of ESD standard(MIL-STD). As a result, with the flyback method and the air gap of relay, we can make ESD tester whose parasitic components are minimized.

HBM ESD Tester for On-wafer Test using Flyback Method (Flyback방식을 이용한 on-wafer용 HBM ESD 테스터 구현)

  • 박창근;염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.469-472
    • /
    • 2002
  • We made ESD tester to measure ESD threshold voltage of semiconductor devices. The HBM ESD test is the most popular method to measure the ESD threshold voltage of MMIC. We use flyback method which is one of the DC-DC converter to get high ESD voltage. With flyback method, we can isolate the low voltage part from the high voltage part of HBM ESD tester. We use an air gap of the relay which is used for switch to satisfy the rise time of ESD standard(MIL-STll-883D). As a result, with the flyback method and the air gap of relay, we can make ESD tester whose parasitic components are minimized.

  • PDF

Changes of Surface Properties by Plasma Treatment on the Surface of Semiconductive Silicone Rubber (반도전성 실리콘 고무의 플라즈마 처리에 따른 표면의 특성변화)

  • Lee, Ki-Taek;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.696-701
    • /
    • 2005
  • This paper was investigated the changes of surface properties of high-temperature-vulcanized (HTV) semiconductive silicone rubber due to oxygen plasma discharge. The modifications produced on the silicone rubber surface by oxygen plasma were accessed using Fourier transform infrared spectroscopy(FTIR), X-ray photoelectron spectroscopy(XPS), contact angle and Surface Roughness Tester. The results of the chemical analysis Showed that C-H bonds were broken due to plasma discharge and Silica-like bonds (SiOx, x=$3\~4$) increased. It is thought that the above changes lead to the increase of surface energy of high-temperature-vulcanized (HTV) semiconductive silicone rubber also, Surface roughness was increased with cleavage of side-chains and oxidation process, it confirmed change as the SEM. The micromorphology of surface and hydrophobicity due to plasma discharge based on our results were discussed.

An Electrical Installation Failure Signal Detection using Time-Energy Analysis (시간-에너지 분석을 이용한 전기설비 이상신호 검출)

  • Jee S. W.;Lee C. H.;Kim Ch. N.;Lee K. S.;Sim K. Y.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.82-87
    • /
    • 2006
  • Most of electric accidents are happened in the place where activities are frequent by common people who has low electric knowledge. Also, accidents are increased in the low voltage electric equipment. So, it is increased to spread the dispersion or non-utility power generation system. It means that ordinary times observation is required for electric equipments by common people. This paper is studied for the diagnosis method of electric equipment that common people can diagnose easily Voltage is generally and exactly measured in the electric and electronic field. We suggest new analysis tools using only electric voltage. It is called the Time-Energy analysis. The Time-Energy analysis is as following First, divide measured voltage waves into same parts, Second, conducted FFT(Fast Fourier Transform) transform for each divided period, Finally, each results are reassembled after graphic treatment. We compared Time-Energy analysis with discharge form by tracking tester. As the result, tracking discharge processes distinguished clearly.

Improved Adhesion of DLC Films by using a Nitriding Layer on AISI H13 Substrate

  • Park, Min-Seok;Kim, Dae-Young;Shin, Chang-Seouk;Kim, Wang Ryeol
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.307-314
    • /
    • 2021
  • Diamond-like carbon (DLC) is difficult to achieve sufficient adhesion because of weak bonding between DLC film and the substrate. The purpose of this study is to improve the adhesion between substrate and DLC film. DLC film was deposited on AISI H13 using linear ion source. To improve adhesion, the substrate was treated by dual post plasma nitriding. In order to define the mechanism of the improvement in adhesive strength, the gradient layer between substrate and DLC film was analyzed by Glow Discharge Spectrometer (GDS) and Scanning Electron Microscope (SEM). The microstructure of the DLC film was analyzed using a micro Raman spectrometer. Mechanical properties were measured by nano-indentation, micro vickers hardness tester and tribology tester. The characteristic of adhesion was observed by scratch test. The adhesion of the DLC film was enhanced by active screen plasma nitriding layer.

A Study on the Algorithm of Battery SOH Estimation for Battery Management System(BMS) (배터리관리시스템(BMS)을 이용한 배터리 잔존수명(SOH) 추정 알고리즘에 관한 연구)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.317-320
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) and State Of Health(SOH) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOH, through the experiments which using the charge and discharge tester and the field tests.

  • PDF