• Title/Summary/Keyword: Discharge change

Search Result 1,177, Processing Time 0.025 seconds

A Study on the Control of Luminous Color in Gas Discharge Tubes

  • Lee, Jong-Chan;Her, In-Sung;Park, Yong-Sung;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, pulsed discharge is used to control the luminous color in gas discharge tubes. The luminous color of the positive column in gas discharge tubes filled with Hg-Ar-Ne (1: 9, 60[Torr]) and having no phosphor material, varies from red to blue emitted by the Ne and Hg from the pulsed discharge. With changing of pulse-width and frequency, the electron temperature in the transient period affects changes to the residual ion and metastable atom densities. The first metastable atoms containing energy levels of about 16.6 [eV]have a very high probability that a collision will result in the ionization potential of Ar being 15.8 [eV]. The change of locus in the CIE chromaticity diagram with increasing pulse-width and frequency approves the variation of luminous color.

The Charecteristics of Superposed Discharge Type Ozonizing System Considering the Change of Temperature of. the Supplied Gas (원료가스의 온도변화를 고려한 중첩방전형 오존발생장치의 특성)

  • Lee, Sang-Keun;Song, Hyun-Jig;Chun, Byung-Joon;Kim, Yeong-Hun;Kim, Sang-Gu;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1705-1707
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer was designed and manufactured. The ozonizer is equipped with three electrodes : central electrode, internal electrode and external electrode, and it consists of two gaps. The ozone is generated by superposing silent discharge, which are respectively generated betweens two gaps. This paper describes the following two characteristics : (1) 'the characteristics of discharge with variation with output voltage of AC High Voltage source, quantity of the supplied gas and discharge voltage (2) the characteristics of ozone discharge power, temperature of the supplied gas.

  • PDF

Flood Discharge Analysis on Land Use Changes in Han Stream, Jeju Island (토지이용변화에 따른 한천유역의 홍수유출 변동 분석)

  • Yang, Se-Chang;Yang, Sung-Kee;Lee, Jun-Ho;Jung, Woo-Yul;Ko, Kwang-Hyo
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.425-435
    • /
    • 2015
  • A number of projects for development have been done continuously due to the increase of tourist in Jeju Island. However flood disaster countermeasure due to urbanization is not considered during this development projects. This study is to make basic process for the flood estimation in Han stream of Jeju Island. The variation of stream discharge due the every 5 years' land use change from 1980 to 2005. Data for flood events (rainfall and discharge) were collected for HEC-HMS model. Clark method was used for unit hydrograph analysis. For the estimation of Clark unit hydrograph parameters, Kraven II and Sabol's empirical equations were applied. The peak discharge increased 9.9~33.67% and total discharge amount increased 12.53~30.21%. Also, time of concentration for peak discharge was reduced by 10 minutes for each event.

The 2-dimensional Discharge Cell Simulation for the Analysis of the Peset and Addressing of an Alternating Current Plasma Display Panel

  • Kim, Joong-Kyun;Chung, Woo-Jun;Seo, Jeong-Hyun;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.24-33
    • /
    • 2001
  • The characteristics of the reset and the address discharges of an alternating current Plasma Display Panel (ac PDP) were studied using 2-dimensional numerical discharge cell simulation. We investigated the wall charge variations during the reset discharge adopting ramping reset pulse and the subsequent addressing discharge. The roles of the ramping reset scheme can be divided into two stages, each electrode gathers wall charges during ramping-up of the initial stage and the built-up wall charges are lost during ramping-down of the later stage. Address discharge does not only change the wall charge distributions on the address and the scan electrodes but also on the sustain electrode. The increase in the wall charges on the sustain electrode was observed with the variation of the applied voltage to the sustain electrode during the address period. The increase of the applied voltage to the sustain electrode during the address period is expected to induce the decrease of the sustain voltage during the display period.

  • PDF

The development of discharge reactor for water purification and the fundamental study on the change of water characteristics (수질 개선용 방전 리액터의 개발과 기본적 수질 특성 변화 조사)

  • Han, Sang-Bo;Park, Jae-Youn;Kim, Jong-Seog;Jung, Jang-Gun;Koh, Hee-Seog;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2193-2195
    • /
    • 2005
  • The hybrid discharge reactor was designed for the application of wastewater treatment and the removal of hazardous volatile organic substances in water. This discharge type was similar to the barrier discharge, and the surface discharge on the dielectric surface was propagated to the water surface. That caused the heterogeneous chemical reaction strongly at the interface between the working gases and the water surface. Changes of the conductivity, acidity, and the dissolved ozone with respect to the treatment time and water quantities were studied as the fundamental experiment. The concentration of hydrogen ions largely increased with increasing the treatment time and the conductivity increased with respect to the increase of water quantities under the constant other discharge parameters.

  • PDF

A Study on Operation Characteristics of Three Electrode Trigger Gap Switch (3전극 트리거 갭 스위치 동작특성에 관한 연구)

  • Hong, Tae-Yun;Han, Sang-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.

Changes of Surface Properties by Plasma Treatment on the Surface of Semiconductive Silicone Rubber (반도전성 실리콘 고무의 플라즈마 처리에 따른 표면의 특성변화)

  • Lee, Ki-Taek;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.696-701
    • /
    • 2005
  • This paper was investigated the changes of surface properties of high-temperature-vulcanized (HTV) semiconductive silicone rubber due to oxygen plasma discharge. The modifications produced on the silicone rubber surface by oxygen plasma were accessed using Fourier transform infrared spectroscopy(FTIR), X-ray photoelectron spectroscopy(XPS), contact angle and Surface Roughness Tester. The results of the chemical analysis Showed that C-H bonds were broken due to plasma discharge and Silica-like bonds (SiOx, x=$3\~4$) increased. It is thought that the above changes lead to the increase of surface energy of high-temperature-vulcanized (HTV) semiconductive silicone rubber also, Surface roughness was increased with cleavage of side-chains and oxidation process, it confirmed change as the SEM. The micromorphology of surface and hydrophobicity due to plasma discharge based on our results were discussed.

Observation of Negative Resistance Region in Voltage-current Curve of Hollow Cathode Discharge (속이 빈 원통형음극 방전의 전압-전류 곡선에서 음 저항 영역 관찰)

  • Lee, Jun-Hoi;Lee, Sung-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.870-875
    • /
    • 2005
  • We measured the optogalvanic signal and discharge voltage-current(V-I) curve under the two different discharge conditions with different buffer gases, Ar, and Ne. When the Gd was used as a cathode material at low discharge current less than 10mA, a significant change was observed in the current-voltage curve. Time resolved optogalvanic signal measurement were measured by the diode laser of which wavelengths correspond to metastable transition line of these gases (Ar, Ne). From these measurements, we found that the characteristics of the V-I curve strongly depend on the Penning ionization process.

Partial Discharge Resistance According to Frequency Acceleration Deterioration of Epoxy/Layered Silicate Nanocomposites (에폭시/층상실리케이트 나노콤포지트의 주파수 가속열화에 따른 부분방전 저항성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1694-1699
    • /
    • 2013
  • Frequency accelerated partial discharge resistance (PDR) aging of epoxy/layered silicate nanocomposite with 1.5wt % additions of layered silicate was investigated in comparison with that of epoxy without layered silicate in terms of PD(partial discharge) erosion depth. It was found that the change in the erosion depth is far smaller in specimens with layered silicate than those without layered silicate nano particles. Frequency acceleration can be done from 60Hz to 1000Hz. But the depth of erosion is less proportional to frequency. Acceleration factor is almost 2 times between 500Hz and 1000Hz, but it is much less than about 8.3 times between 60Hz and 500Hz. This superior PD resistance is caused by the presence of nanofillers, anano-effect due to closely packed nanofillers, and strong chemical bonds at layered silicate nanofillers /resin interfaces.

Discharge Characteristics of a Plasma Display using Vertical Auxiliary Electrodes

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 2008
  • In a conventional plasma display, the bus electrode was located on the ITO electrode at the outer part of each cell. We propose a new electrode configuration using vertical auxiliary electrodes which play a role of electrically connecting ITO and bus electrodes with the aim of enhancing discharge and luminous characteristics of the PDP (Plasma Display Panel). In this paper, luminance and luminous efficiency of the 3 in.-diagonal test panel are measured with various number of vertical auxiliary electrodes such as 2, 50 and 150. The change in the luminous characteristics is explained in connection with the discharge characteristics of the PDP cells such as current peak, IR emission peak and ICCD picture image.