• 제목/요약/키워드: Direct current

검색결과 2,754건 처리시간 0.031초

BLDC 전동기의 토크리플 저감에 대한 연구 (Research of Torque Ripple Reduction of BLDC Motor)

  • 남기용;홍정표;이춘만;정원지
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1455-1458
    • /
    • 2005
  • This paper presents the method of reducing torque ripple of Blushless Direct Current(BLDC) motor. In the BLDC motor, the torque is decided by the back-EMF and current waveform. If the back-EMF is constant, the torque ripple depends on the current ripple during commutation period. The current in commutation period is acquired by circuit analysis and then the torque ripple simply can be reduced by varying input voltage to flow the current continuously. And suggested method is confirmed by dynamic with parameters of 500W BLDC motor.

  • PDF

Improved Active Power Filter Performance Based on an Indirect Current Control Technique

  • Adel, Mohamed;Zaid, Sherif;Mahgoub, Osama
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.931-937
    • /
    • 2011
  • This paper presents a method for the performance improvement of a shunt active power filter (SAPF) using the indirect current control (ICC) scheme. Compared to the conventional direct current control (DCC) scheme, the ICC gives better performance with a lower number of sensors. A simplified and efficient control algorithm using a low cost Intel 80C196KC microcontroller is implemented using only two current sensors for the source current and one voltage sensor for the DC-link voltage of the SAPF circuit. The objective is to eliminate harmonics and to compensate the reactive power produced by non-linear loads such as an uncontrolled rectifier feeding an inductive load. The APF is realized using a three phase voltage source inverter (VSI) with a dc bus capacitor. Experimental results are presented to prove the better performance of the ICC method over the DCC one.

전위변화에 의한 콘크리트내의 철근방식에 관한 연구 (Study on the Corrosionproofing in Concrete by Cathodic Protection)

  • 임서형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권2호
    • /
    • pp.213-220
    • /
    • 1999
  • The purpose of this study is to apply cathodic protection to reinforced concrete structure and provide fundamental data to prevent the corrosion. The theory of cathodic protection of steel in concrete is to apply sufficient direct current so that corroding anodes on the steel are prevented from discharging ions. Two methods are used to supply the external current. In one, the protected metal is the cathode by connecting it to a more active metal. In the second, an external direct current power source supplies the current. The first is the sacrificial-anode system and the second the impressed-current system. The study results showed that the corrosion of the reinforcing steel in concrete could be enormously decreased by using protective current. The sacrificial anode and concrete nave to be adhered closely each in order to prevent the corrosion of reinforcing steel.

  • PDF

Changes in Sensory Function After Transcranial Direct Current Stimulation on Primary Motor Cortex Area

  • Min, Dong-Ki
    • 한국전문물리치료학회지
    • /
    • 제21권4호
    • /
    • pp.1-8
    • /
    • 2014
  • Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers low-intensity direct current to cortical areas, thereby facilitating or inhibiting spontaneous neuronal activity. This study was designed to investigate changes in various sensory functions after tDCS. We conducted a single-center, single-blinded, randomized trial to determine the effect of a single session of tDCS with the current perception threshold (CPT) in 50 healthy volunteers. Nerve conduction studies were performed in relation to the median sensory and motor nerves on the dominant hand to discriminate peripheral nerve lesions. The subjects received anodal tDCS with 1 mA for 15 minutes under two different conditions, with 25 subjects in each groups: the conditions were as follows tDCS on the primary motor cortex (M1) and sham tDCS on M1. We recorded the parameters of the CPT a with Neurometer$^{(R)}$ at frequencies of 2000, 250, and 5 Hz in the dominant index finger to assess the tactile sense, fast pain and slow pain, respectively. In the test to measure CPT values of the M1 in the tDCS group, the values of the distal part of the distal interphalangeal joint of the second finger statistically increased in all of 2000 Hz (p=.000), 250 Hz (p=.002), and 5 Hz (p=.008). However, the values of the sham tDCS group decreased in all of 2000 Hz (p=.285), 250 Hz (p=.552), and 5 Hz (p=.062), and were not statistically significant. These results show that M1 anodal tDCS can modulate sensory perception and pain thresholds in healthy adult volunteers. The study suggests that tDCS may be a useful strategy for treating central neurogenic pain in rehabilitation medicine.

A Strategy for Homogeneous Current Distribution in Direct Methanol Fuel Cells through Spatial Variation of Catalyst Loading

  • Park, Sang-Min;Kim, Sang-Kyung;Peck, Dong-Hyun;Jung, Doo-Hwan
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.331-337
    • /
    • 2017
  • A simple strategy is proposed herein for attaining uniform current distribution in direct methanol fuel cells by varying the catalyst loading over the electrode. In order to use the same total catalyst amount for a serpentine flow field, three spatial variation types of catalyst loading were selected: enhancing the cathode catalyst loading (i) near the cathode outlet, (ii) near the cathode inlet, and (iii) near the lateral areas. These variations in catalyst loading are shown to improve the homogeneity of the current distribution, particularly at lower currents and lower air-flow rates. Among these three variations, increased loading near the lateral areas was shown to contribute most to achieving a homogenous current distribution. The mechanism underlying each catalyst loading variation method is different; very high catalyst-loading is shown to decrease the homogeneity of the distribution, which may be caused by water management in the thick catalyst layer thereof.

직류전위차법 자료에 대한 통계적 자료분석 (Statistical analysis of direct current potential drop data)

  • 이정희;이우동
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권1호
    • /
    • pp.139-146
    • /
    • 2010
  • 비파괴검사방법 중 직류전위차법은 표면균열 측정에 유효한 수단으로 알려져 있다. 이차원 표면 균열을 가진 시험편에서 전류입출력점사이의 거리가 직류전위차에 미치는 영향을 알아보는 실험을 실시하여 자료를 얻었다. 이 자료로부터 전위차 값은 일정 전위차계측점사이의 거리에 있어 전류입출력점사이의 거리가 증가함에 따라 반비례적으로 감소하고, 노치의 길이에 비례하고 있었다. 이 실험에서 관찰된 자료를 통계적 모형에 적합시키고, 적합된 모형에서 전위차에 영향을 주는 유의한 변수를 알아보는 것은 비파괴검사에서 중요하다고 할 수 있다. 본 연구에서는 관찰된 자료를 적절하게 설명할 수 있는 통계적 모형을 제안하고, 제안된 모형에서 유의한 독립변수를 찾아보는 것이 목적이다.

전기도금법을 이용한 태양전지용 CdSe 나노로드 제작 (Electrochemical Deposition of CdSe Nanorods for Photovoltaic Cell)

  • 김성훈;이재호
    • 한국표면공학회지
    • /
    • 제42권2호
    • /
    • pp.63-67
    • /
    • 2009
  • CdSe is one of the composite semiconductor materials used in hybrid solar cell. CdSe nanorods were fabricated using electrochemical deposition in anodic aluminum oxide (AAO) template. CdSe were deposited from $CdSO_4$ and $H_2SeO_3$ dissolved aqueous solution by direct current electrochemical deposition. Uniformity of CdSe nanorods were dependent on the diameter and the height of holes in AAO. The current density, current mode, bath composition and temperature were controlled to obtained 1:1 atomic composition of CdSe. CdSe electroplating in AAO is bottom-up filling so we applied direct current is better than others for good uniformity of CdSe nanorods. The optimum conditions to obtain 1:1 atomic composition of CdSe nanorods are direct current $10\;mA/cm^2$, 0.25 M $CdSO_4$-5 mM $H_2SeO_3$ electrolytes at room temperature.

Direct Current (DC) Bias Stress Characteristics of a Bottom-Gate Thin-Film Transistor with an Amorphous/Microcrystalline Si Double Layer

  • Jeong, Tae-Hoon;Kim, Si-Joon;Kim, Hyun-Jae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권5호
    • /
    • pp.197-199
    • /
    • 2011
  • In this paper, the bottom-gate thin-film transistors (TFTs) were fabricated with an amorphous/microcrystalline Si double layer (DL) as an active layer and the variations of the electrical characteristics were investigated according to the DC bias stresses. Since the fabrication process of DL TFTs was identical to that of the conventional amorphous Si (a-Si) TFTs, it creates no additional manufacturing cost. Moreover, the amorphous/microcrystalline Si DL could possibly improve stability and mass production efficiency. Although the field effect mobility of the typical DL TFTs is similar to that of a-Si TFTs, the DL TFTs had a higher reliability with respect to the direct current (DC) bias stresses.

Estimating Stability of MTDC Systems with Different Control Strategy

  • Nguyen, Thai-Thanh;Son, Ho-Ik;Kim, Hak-Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.443-451
    • /
    • 2015
  • The stability of a multi-terminal direct current (MTDC) system is often influenced by its control strategy. To improve the stability of the MTDC system, the control strategy of the MTDC system must be appropriately adopted. This paper deals with estimating stability of a MTDC system based on the line-commutated converter based high voltage direct current (LCC HVDC) system with an inverter with constant extinction angle (CEA) control or a rectifier with constant ignition angle (CIA) control. In order to evaluate effects of two control strategies on stability, a MTDC system is tested on two conditions: initialization and changing DC power transfer. In order to compare the stability effects of the MTDC system according to each control strategy, a mathematical MTDC model is analyzed in frequency domain and time domain. In addition, Bode stability criterion and transient response are carried out to estimate its stability.

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF