• Title/Summary/Keyword: Dimensional Analysis

Search Result 12,656, Processing Time 0.044 seconds

Effect of Elevated Ultraviolet-B Radiation on Yield and Differential Expression of Proteome in Perilla (perilla frutescens L.) (잎들깨 수량과 단백질체 발현에 미치는 UV-B의 영향)

  • Hong, Seung-Chang;Hwang, Seon-Woong;Chang, An-Cheol;Shin, Pyung-Gyun;Jang, Byoung-Choon;Lee, Chul-Won
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Plastichouse cultivation for crops and vegetables in the winter has been widely popularized in Korea. In the vinylhouse Ultraviolet B penetration is lower than in the field, and so some problems, as plant overgrowth and outbreak of disease, occurred frequently. The effect of artificial supplement ultraviolet B $(UV-B:280{\sim}320nm)$ radiation on the physiological responses and yield of perilla (perilla frutescens) was investigated UV-B ray was radiated on perilla with the 10th leaf stage at the distance of 90, 120 and 150 cm from the plant canopy for 30 days after planting in the vinylhouse. The production of fresh perilla leaves was high in the order of plastic house, ambient+50% of supplemental UV-B, ambient ambient+100% of supplemental UV-B. Enhanced UV-B radiation affected the intensity of thirty-three proteins in 2-dimensional electrophoretic analysis of proteins and ten proteins out of them seemed to be responsive to UV-B : a protein was, ATP synthase CF1 alpha chain, down regulated and nine proteins (Chlorophyll a/b bindng protein type I, Chlorophyll a/b binding protein type II precursor, Photosystem I P700 chlorophyll a apoprotein A2, DNA recombination and repair protein recF, Galactinol synthase, S-adenosyl-L-methionine, Heat shock protein 21, Calcium-dependent protein kinase(CDPK)-like, Catalase) were up-regulated.

A Study on Developing Sensibility Model for Visual Display (시각 디스플레이에서의 감성 모형 개발 -움직임과 색을 중심으로-)

  • 임은영;조경자;한광희
    • Korean Journal of Cognitive Science
    • /
    • v.15 no.2
    • /
    • pp.1-15
    • /
    • 2004
  • The structure of sensibility from motion was developed for the purpose of understanding relationship between sensibilities and physical factors to apply it to dynamic visual display. Seventy adjectives were collected by assessing adequacy to express sensibilities from motion and reporting sensibilities recalled from dynamic displays with achromatic color. Various motion displays with a moving single dot were rated according to the degree of sensibility corresponding to each adjective, on the basis of the Semantic Differential (SD) method. The results of assessment were analyzed by means of the factor analysis to reduce 70 words into 19 fundamental sensibilities from motion. The Multidimensional Scaling (MDS) technique constructed the sensibility space in motion, in which 19 sensibilities were scattered with two dimensions, active-passive and bright-dark Motion types systemically varied in kinematic factors were placed on the two-dimensional space of motion sensibility, in order to analyze important variables affecting sensibility from motion. Patterns of placement indicate that speed and both of cycle and amplitude in trajectories tend to partially determine sensibility. Although color and motion affected sensibility according to the in dimensions, it seemed that combination of motion and color made each have dominant effect individually in a certain sensibility dimension, motion to active-passive and color to bright-dark.

  • PDF

The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients (방광암 환자의 영상유도 방사선치료에 관한 고찰)

  • Bae, Seong-Soo;Bae, Sun-Myoung;Kim, Jin-San;Kang, Tae-Young;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • Purpose: In hospital image-guided radiation therapy in patients with bladder cancer to enhance the reproducibility of the appropriate amount, depending on the patient's condition, and image-guided injection of saline system (On-Board Imager system, OBI, VARIAN, USA) three of the Cone-Beam CT dimensional matching (3D-3D matching) to be the treatment. In this study, the treatment of patients with bladder cancer at Cone-Beam CT image obtained through the analysis of the bones based matching and matching based on the bladder to learn about the differences, the bladder's volume change injected saline solution by looking at the bladder for the treatment of patients with a more appropriate image matching is to assess how the discussion. Materials and Methods: At our hospital from January 2009 to April 2010 admitted for radiation therapy patients, 7 patients with bladder cancer using a Folly catheter of residual urine in the bladder after removing the amount determined according to individual patient enough to inject saline CT-Sim was designed after the treatment plan. After that, using OBI before treatment to confirm position with Cone-Beam CT scan was physician in charge of matching was performed in all patients. CBCT images using a total of 45 bones, bladder, based on image matching and image matching based on the difference were analyzed. In addition, changes in bladder volume of Eclipse (version 8.0, VARIAN, USA) persuaded through. Results: Bones, one based image matching based on the bladder and re-matching the X axis is the difference between the average $3{\pm}2mm$, Y axis, $1.8{\pm}1.3mm$, Z-axis travel distance is $2.3{\pm}1.7mm$ and the overall $4.8{\pm}2.0mm$, respectively. The volume of the bladder compared to the baseline showed a difference of $4.03{\pm}3.97%$. Conclusion: Anatomical location and nature of the bladder due to internal movement of the bones, even after matching with the image of the bladder occurred in different locations. In addition, the volume of saline-filled bladder showed up the difference between the 4.03 percent, but matched in both images to be included in the planned volumes were able to confirm. Thus, after injection of saline into the bladder base by providing a more accurate image matching will be able to conduct therapy.

  • PDF

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

It Doesn't Taste the same from Someone Else's Plate: The Influence of Culture in Interpersonal Retail Service Evaluations (별인적반자적미도불일양(别人的盘子的味道不一样): 문화대인제령수복무평개적영향(文化对人际零售服务评价的影响))

  • Spielmann, Nathalie;Kim, Ju-Ran
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.2
    • /
    • pp.164-172
    • /
    • 2010
  • This study reviews the influence of culture in interpersonal servicescapes by examining the restaurant retail setting. Two cultures (Canada and France) are surveyed in order to better understand their retail expectations towards interpersonal servicescapes. Using Hofstede's (1991) cultural dimensions to explain some of the differences between Canadian and French restaurant patrons, this study demonstrates a potentially interesting research avenue in the field of cross-cultural interpersonal services marketing. It demonstrates that cultural dimensions do not operate independently but interdependently. Understanding this can help retailers better explain complex service interactions between countries that may appear similar in terms of various socio-demographic features. In this exploratory research, a measure via exploratory factor analysis was developed, one that encompasses both the physical and service aspects common to interpersonal servicescape by using personality traits. This measure was tested in order to better understand the service expectations between two cultures, Canada and France. Five dimensional structures were uncovered in both cultures but with different traits and groupings. The differences between the traits uncovered and the overall Canadian and French personality structures find some explanation using Hofstede's (1991) cultural dimensions. The results of this survey point to a possible explanation as to why when services are transferred between cultures, the perceptions of them can be different and sometimes even lead to service failure. There are clearly some cultural differences between the Canadian and French consumers and their overall expectations regarding their consumption experience. Reviewing the first factor of the French and Canadian personality structures shows that the individualist/collectivist differences are apparent between the Canadian and the French cultures. The second dimension also has quite a few traits in common, five, all of which have the personal treatment aspect of the restaurant experience that a service provider would be responsible for: polite, respectful, and dedicated. Notable is that the French dimension does not include the authenticity or the hospitable aspect of the experience but includes even more features that are inherent to the personal interaction, such as charming and courteous. The third dimension of the Canadian and French structures reflects completely different expectations. Whereas the French dimension centers around energy and enthusiasm, the Canadian version is more laid-back and relaxed. There is extroversion in the French dimension to introversion in the Canadian dimension. This could be explained by differences on the Uncertainty Avoidance dimension as outlined by Hofstede (1991). The fourth dimension seems to confirm previously outlined cultural differences. Whereas Canadians, being a bit lower on uncertainty avoidance and power distance, prefer an intimate and private experience, the French continue to expect extraversion and inclusive features to their experience. The fifth dimension is in the French personality structure a clear expression of the high power distance society, where the roles of the players in the restaurant experience are clearly defined and the rules of engagement preserved. This study demonstrates that different cultures clearly do relate to different expectations regarding interpersonal services. This is apparent in the dimensions that come up in both the French and the Canadian personality structures, not only in terms of how different they are but also in with which cultural dimensions these can be explained. For interpersonal servicescapes, the use of personality traits is interesting as it allows for both physical and service features to be accounted for. Furthermore, the social component inherent to interpersonal servicescapes surfaces in most of the dimensions of the service personality structures. The quality of social exchanges is extremely important, and this even more so in cross-cultural situations, where the expec tations regarding the service experience may vary. As demonstrated by this research and using Hofstede's (1991) paradigm, not all societies will have the same expectations pertaining to the interpersonal services. Furthermore, the traditions surrounding the type of service can also have an impact on the service evaluations and differ between countries and cultures. However, using personality traits may also allow for retailers to see which service traits are common to two or more cultures where they seek to be present, and focus on these in the offering. The findings demonstrate the importance of the individualist and collectivist dimension for interpersonal servicescapes. This difference between the French and the Canadian personality structure is apparent in the most dominant dimension as well as within others. The findings are a step in explaining how retailers can transfer and then measure interpersonal services across cultures.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Color stability of three dimensional-printed denture teeth exposed to various colorants (다양한 색소에 대한 3D 프린팅 인공치의 색 안정성)

  • Koh, Eun-Sol;Cha, Hyun-Suk;Kim, Tae-Hyung;Ahn, Jin-Soo;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • Purpose: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants. Materials and methods: Four types of conventional prefabricated denture teeth (Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D-printed denture teeth (Dentca); and Z250 (Filtek Z250, 3M ESPE) were prepared for testing. The samples were immersed in erythrosine 3%, coffee, cola, and distilled water (DW) at 37℃. Color change (ΔE) was measured by spectrophotometer before immersion and at 7, 14, and 21 days after immersion. One-way analysis of variance was performed along with Tukey's honestly significant difference multiple comparisons test (P<.05). Results: No great difference was observed between the color change of Dentca denture teeth and that of conventional denture teeth in most cases (P>.05). The color change of Dentca denture teeth immersed in erythrosine 3% was greater than that of Surpass (ΔE = 0.67 ± 0.25) after 1 week; Artic 6 (ΔE = 1.44 ± 0.38) and Premium 6 (ΔE = 1.69 ± 0.35) after 2 weeks; and Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), and Preference (ΔE = 2.01 ± 0.75) after 3 weeks (P<.05). Conclusion: A color change was observed in Dentca denture teeth when immersed in some colorants; however, the maximum value of ΔE for Dentca denture teeth was within the clinically acceptable range.