• 제목/요약/키워드: Digital fuzzy system

검색결과 248건 처리시간 0.035초

지능형 디지털 재설계 기법을 이용한 비선형 전력 계통의 강인 퍼지 부하 주파수 제어 (Robust Fuzzy Load-Frequency Control of Nonlinear Power Systems Using Intelligent Digital Redesign Technique)

  • 이남수;이연우;전상원;주영훈
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 춘계학술대회 학술발표 논문집
    • /
    • pp.142-145
    • /
    • 2000
  • A new robust load-frequency control (LFC) methodology is proposed for nonlinear power systems with the valve position limits of the governor in the presence of parametric uncertainties. The Takagi-Sugeno (TS) fuzzy model is adopted for fuzzy modeling of the nonlinear power system. A sufficient condition of the robust stability is presented in the sense of Lyapunov for the TS fuzzy model with parametric uncertainties. The intelligent digital redesign technique for the uncertain nonlinear power system is also studied. The effectiveness of the proposed robust fuzzy LFC controller design method is demonstrated through a numerical simulation.

  • PDF

화력 발전소 드럼형 보일러 시스템의 고장 진단을 위한 퍼지 전문가 시스템의 개발 (Development of Fuzzy Expert System for Fault Diagnosis in a Drum-type Boiler System of Fossil Power Plant)

  • 변승현;박세화
    • 전자공학회논문지B
    • /
    • 제31B권10호
    • /
    • pp.53-66
    • /
    • 1994
  • In this paper, a fuzzy expert system is developed for fault diagnoisis of a drum-type boiler system in fossil power plants. The develped fuzzy espert system is composed of knowledge base, fuzzification module, knowledge base process module, knowledge base management module, inference module, and linguistic approximation module. The main objective of the fuzzy expert system is to check the states of the system including the drum level and detect faults such as the feedwater flow sensor fault, feedwater flow control valve fault, and water wall bube rupture. The fuzzy expert system diagnoses faults using process values, manipulated values, and knowledge base which is built via interviews and questionaries with the experts on the plant operations. Finally, the validity of the developed fuzzy expert system is shown via experiments using the digital simulator for boiler system is Seoul Power Plant Unit 4.

  • PDF

The Application of Fuzzy Reaching Law Control in AC Position Servo System

  • Yang Yangxi;Liu Ding
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.360-364
    • /
    • 2001
  • In this paper, a novel method of reaching law variable structure control based on fuzzy rules is present, which is that the reaching law parameters is on-line adjusted by fuzzy rules. This method is used in a digital ac position servo system, the experiment results show that the system designed by this method has both satisfactory quality and very smaller chattering.

  • PDF

Design of digital nuclear power small reactor once-through steam generator control system

  • Qian, Hong;Zou, Mingyao
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2435-2443
    • /
    • 2022
  • The once-through steam generator used in the small modular reactor needs to consider the stability of the outlet steam pressure and steam superheat of the secondary circuit to achieve better operating efficiency. For this reason, this paper designs a controllable operation scheme for the steam pressure and superheat of the small reactor once-through steam generator. On this basis, designs a variable universe fuzzy controller, first, design the fuzzy control rules to make the controller adjust the PI controller parameters according to the change of the error; secondly, use the domain adjustment factor to further subdivide the input and output domain of the fuzzy controller according to the change of the error, to improve the system control performance. The simulation results show that the operation scheme proposed in this paper have better system performance than the original scheme of the small reactor system, and controller proposed in this paper have better control performance than traditional PI controller and fuzzy PI controller, what's more, the designed control system also showed better anti-disturbance performance in lifting experiment between 100% and 80% working conditions. Finally, the experimental platform formed by connecting the digital small reactor with Matlab/Simulink through OPC(OLE for Process Control) communication technology also verified the feasibility of the proposed scheme.

모터 보호, 고장진단 및 제어를 위한 디지털 보호계전기 활용 전력감시제어 시스템 설계 (A Design of Power Management and Control System using Digital Protective Relay for Motor Protection, Fault Diagnosis and Control)

  • 이성환;안인석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.516-523
    • /
    • 2000
  • In this paper, intelligent methods using digital protective relay in power supervisory control system is developed in order to protect power systems by means of timely fault detection and diagnosis during operation for induction motor which has various load environments and capacities in power systems. The spectrum pattern of input currents was used to monitor to state of induction motors, and by clustering the spectrum pattern of input currents, the newly occurrence of spectrums pattern caused by faults were detected. For diagnosis of the fault detected, the fuzzy fault tree was derived, and the fuzzy relation equation representing the relation between an induction motor fault and each fault type, was solved. The solution of the fuzzy relation equation shows the possibility of each fault's occurring. The results obtained are summarized as follows: 1) The test result on the basis of KEMC1120 and IEC60255, show that the operation time error of the digital motor protective relay is improved within ${\pm}5%$. 2) Using clustering algorithm by unsupervisory learning, an on-line fault detection method, not affected by the characteristics of loads and rates, was implemented, and the degree of dependency by experts during fault detection was reduced. 3) With the fuzzy fault tree, fault diagnosis process became systematic and expandable to the whole system, and the diagnosis for sub-systems can be made as an object-oriented module.

  • PDF

A study on Improvement for distorted images of the Digital X-ray Scanner System based on Fuzzy Correction Algorithm

  • Baek, Jae-Ho;Kim, Kyung-Jung;Park, Mi-Gnon
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.173-176
    • /
    • 2005
  • This paper proposes a fuzzy correction algorithm that can correct the distorted medical image caused by the scanning nonlinear velocity of the Digital X-ray Scanner System (DX-Scanner) using the Multichannel Ionization Chamber (MIC). In the DX-Scanner, the scanned medical image is distorted for reasons of unsuitable integration time at the nonlinear acceleration period of the AC servo motor during the inspection of patients. The proposed algorithm finds the nonlinear motor velocity modeling through fuzzy system by clustering and reconstructs the normal medical image lines by calculating the suitable moving distance with the velocity of the motor using the modeling, acceleration time and integration time. In addition, several image processing is included in the algorithm. This algorithm analyzes exact pixel lines by comparing the distance of the acceleration period with the distance of the uniform velocity period in every integration time and is able to compensate for the velocity of the acceleration period. By applying the proposed algorithm to the test pattern for checking the image resolution, the effectiveness of this algorithm is verified. The corrected image obtained from distorted image is similar to the normal and better image for a doctor's diagnosis.

  • PDF

퍼지PID제어를 이용한 추종 제어기 설계 (Fuzzy PID Controller Design for Tracking Control)

  • 김봉주;정정주
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.68-68
    • /
    • 2000
  • This paper presents a fuzzy modified PID controller that uses linear fuzzy inference method. In this structure, the proportional and derivative gains vary with the output of the system under control. 2-input PD type fuzzy controller is designed to obtain the varying gains. The proposed fuzzy PID structure maintains the same performance as the general-purpose linear PID controller, and enhances the tracking performance over a wide range of input. Numerical simulations and experimental results show the effectiveness of the fuzzy PID controller in comparison with the conventional PID controller.

  • PDF

지능형 디지털 재설계 기법을 이용한 원자력 발전소 증기발생기의 강인 제어기 설계 (Design of Robust Controller for the Steam Generator in the Nuclear Power Plant Using Intelligent Digital Redesign)

  • 김주원;박진배;조광래;주영훈
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2002년도 춘계학술대회 및 임시총회
    • /
    • pp.203-206
    • /
    • 2002
  • This paper describes fuzzy control methodologies of the steam generator which have nonlinear characteristics in the nuclear power plant. Actually, the steam generator part of the power generator has a problem to control water level because it has complex components and nonlinear characteristics. In order to control nonlinear terms of the model, Takagj-Sugeno (75) fuzzy system is used to design a controller. In designing procedure, intelligent digital redesign method is used to control the nonlinear system. This digital controller keeps the performance of the analog controller. Simulation examples are included for ensuring the proposed control method.

  • PDF

비선형 시스템 제어를 위한 지능형 디지털 PAM 퍼지 제어기 (Intelligent Digital PAM Fuzzy Controller for Nonlinear Systems)

  • 이상준;차대범;주영훈;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2002-2004
    • /
    • 2001
  • In this paper, we propose the PAM fuzzy controller using intelligent digital redesign method for nonlinear system. We design the continuous-time controller using TSK fuzzy model of nonlinear system, and then design the intelligent digital PAM controller based on continuous-time controller. Finally, the feasibility and stability of the proposed method has been proven through a computer simulation.

  • PDF

Modeling of Dynamic Hysteresis Based on Takagi-Sugeno Fuzzy Duhem Model

  • Lee, Sang-Yun;Park, Mignon;Baek, Jaeho
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제13권4호
    • /
    • pp.277-283
    • /
    • 2013
  • In this study, we propose a novel method for modeling dynamic hysteresis. Hysteresis is a widespread phenomenon that is observed in many physical systems. Many different models have been developed for representing a hysteretic system. Among them, the Duhem model is a classical nonlinear dynamic hysteresis model satisfying the properties of hysteresis. The purpose of this work is to develop a novel method that expresses the local dynamics of the Duhem model by a linear system model. Our approach utilizes a certain type of fuzzy system that is based on Takagi-Sugeno (T-S) fuzzy models. The proposed T-S fuzzy Duhem model is achieved by fuzzy blending of the linear system model. A simulated example applied to shape memory alloy actuators, which have typical hysteretic properties, illustrates the applicability of our proposed scheme.