• Title/Summary/Keyword: Digital electric device

Search Result 80, Processing Time 0.032 seconds

Development of Knee Weight-bearing Radiography Assist Device (무릎 체중부하 촬영 보조장치 개발)

  • Yon-Lae Kim;Young-Woo Yoon
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.395-399
    • /
    • 2023
  • The knee arthritis patients are generally performed standing position radiography. However, patients with pain caused by degenerative diseases or injuries in the knee have difficulty maintaining a standing position. Therefore, this study aims to develop a knee joint standing weight bearing projection assist device to solve these problems when patients undergo knee radiography due to various diseases. The design of the knee joint weight-bearing radiography assist device is carried out with 3D design and drawing production to secure basic data, electric support and frame manufacture. A fixed device for maintaining the patient's knee standing weight-bearing projection, an electric digital height device, a digital protractor, and a safety device were designed. The arm support is made of PVC with a cushion to relieve the impact and make it easier to remove debris. The digital electric device can be moved up and down according to the patient's height, and a remote control is attached. The safety device is made to be adjustable in size by attaching metal hooks on both sides of the frame and to shield the scrotum. A digital protractor was attached to the side frame to set the desired knee angle. When a self-made assist device was used to perform a knee joint standing weight bearing projection, it helped maintain arm support and lower extremities position. In addition, the height could be adjusted using an assist device during standing projections, which helped the patient maintain the position.

A Study on the Test Method of Local Information Processing Device in Digital Substation Based on IEC 61850 (IEC 61850 기반 디지털변전소 현장정보처리장치 시험 방법에 관한 연구)

  • Kim, Nam-Dae;Kim, Woo-Jung;Lee, Nam-Ho;Kim, Seok-Kon;Jang, Byung-Tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.253-257
    • /
    • 2020
  • The local information processing devices are devices that process information by converting voltage, current, and digital electric signals from legacy-type power facility into IEC 61850 based data. It acquires and processes the operation information of legacy-type power facility, performs control of power facility, and interlock function using internal logic. In particular, the time to convert data to process input and output information for a device is important because a number of protection relay input and output signals are handled by only one device. This paper introduces test methods and cases for measuring IEC 61850 communication function and input/output data conversion time of local information processing device.

The Implementation of IED for Diagnosis of Electric Devices (전력 설비 진단을 위한 IED 의 구현)

  • Oh, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1110-1111
    • /
    • 2007
  • These days, the concerns about maintenance and repair of electric facilities for stable and reliable electric power supply are increasing day by day. Because, we can have enormous damages economically and socially from a problem of the facilities, no matter how it is a small one. Especially, electric facilities in our country had been built abruptly from 40 years ago, so it can be thought that here are great amount of old facilities that must be repaired or replaced with new one, and the number would be increased time by time. On this situation, many researchers are studying the efficient and reliable method of maintenance for electric facilities and the results are applied on the facilities gradually by growing interests of operators and managers of the facilities. In this paper, the IED(Intelligent Electronic Devices) for Diagnosis system of electric machines are described. It takes analog data from a sensing device and operates digital processor to get a optimum digital data for diagnosis system. Now, this device is applied on several high voltage substations to diagnose and maintain GIS. Brief schematic of total diagnosis system and the construction of the IED are included in this paper.

  • PDF

An Active Damping Device for a Distributed Power System (전력시스템을 위한 Active Damping Device)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Distributed power systems (DPSs) has been widely used various industrial/military applications due to their various advantages. Furthermore, the "All electric" concept, in conjunction with DC DPS, appears to be more advanced and mature in the AEV(All-Electric Vehicular) industry. Generally, AEV carry many loads with varied functions. However, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and a simple adaptive controller is proposed as a active damping device to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. In addition, the proposed control approach has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. The control algorithm has been implemented on a TMS320F2812 Digital Signal Processor (DSP). Simulation and experimental results are presented which verify the proposed control principle and demonstrate the practicality of the circuit topology.

A Study of Function Verification of Digital Excitation System with Real Time Simulator (시뮬레이터 탑재형 디지털 여자시스템 기능검증 시험에 관한 연구)

  • Ryu, Ho-Seon;Shin, Man-Su;Lee, Joo-Hyun;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1191-1192
    • /
    • 2011
  • We released new triple redundant digital excitation system with real time generator-turbine simulator. One of its great merits is the real time generator-turbine simulator when it was compared with the other products. If excitation system is tripped by unexpected faults, Maintenance man can do easily performance test of digital excitation control board, sequence relay and thyristor switching device of phase controlled rectifier without manufacturer's support. For the verification of this system, It was tested with an actual excitation system implemented on 5kVA M-G Set. After finishing the tests, the trial product will be installed and operated at a 500MW thermal power plant.

  • PDF

Development of the Ubiquitous-based Intelligent Digital Switchgear Panel for Home Automation (유비쿼터스 기반의 주택 자동화용 디지털 분전반 개발)

  • Ko, Yun-Seok;Kim, Ho-Yong;Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.741-747
    • /
    • 2008
  • This paper proposes a new concept of IDSP(Intelligent Digital Switchgear Panel) which can solve the problem of the safety, the reliability and the convenience to correspond to the requirement of the general electric customer or electric power company under the ubiquitous-based home automation environments. By analyzing their requirement functions, a 32-bit micro processor is adopted as main controller to support the designed functions efficiently. The DSP-based single phase power management device is utilized to collect the electric power information and the ethernet convertor to communicate through internet among the IDSPs and the remote computer system. In the proposed IDSP, the several functions are implemented such as the earth leakage level display and waveform transmission, the electric fee display, the voltage management, the load management and the load control function. Finally, the prototype of the IDSP is made experimently based on the designed results, and then the effectiveness is verified by testing its basic functions.

Retinal Projection Display for Low Vision Aid

  • Nakamura, Hajime;Ando, Takahisa;Shimizu, Eiji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.1009-1011
    • /
    • 2002
  • We developed a Retinal Projection Display for a low vision aid. This device can be applied to a low vision whose visual sense is weak. In the device, a digital image was formed with spatial light modulator(SLM) and projected onto a retina with the Maxwellian View. The image on this display can be seen clearly without our ocular accommodation and a low vision can see it without correction of a refraction error.

  • PDF

Interoperability Test of the Digital Substation using IED Conformance Testing System (IED 적합성 시험장치를 이용한 디지털 변전소 상호운용성 시험)

  • Lee, N.H.;Jang, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.11-12
    • /
    • 2007
  • In order to verify a digital substation based on IEC 61850, KEPRI in charge of POWER IT project related to SAS has constructed IED conformance testing system, which consists of HMI, IED (Intelligent Electronic Device), network equipment, V/I generator, and performed the interoperability test between two IEDs made by other vendors. The test was proceeded based on SCL and with system integrated tools

  • PDF

A Study on the Digital Unit Development for Turbine Load Set Control (Turbine Load Set 조정을 위한 Digital Unit 개발)

  • Moon Yong-Seon;Jeong Ho-Jin;Kang Sung-Ryul;Choi Hyeong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.498-503
    • /
    • 2005
  • As important device that decide output load in superannuated thermoelectric power plant which do Turbine Load Set Motor device. This generation of electric power system operated Set Up Range Motor according to Set Up value that operator manufactures by hand circumvolve, and generation of electric power output load derision is consisted by internal action including Motor Therefore, in this research passively output load operated Turbine Motor Drive equipment that can have existing Turbine Load Set Motor Performance developing Digital Drive Unit device design. Also control algorithm implementation and existing Turbine Load Set Motor Drive and connection possibility through designed controlling system to connect basis function that decide development output load with Digital Drive Unit that designed also with existing Motor Drive Unit and can be operated.