• Title/Summary/Keyword: Digital Automation

Search Result 459, Processing Time 0.032 seconds

A Study on Control system design for Automated Cultivation of product (농작물 재배 자동화를 위한 제어시스템 설계에 관한 연구)

  • Cho, Young Seok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.1
    • /
    • pp.55-60
    • /
    • 2014
  • Today, there is increasing the elderly population in rural community, and people of returning from the urban to the rural community are demand to be of high value-added agriculture. In this time, there are required to regularization, standardization, automation, for getting of production of high value crops. In this paper, we are study for automation cultivation control system design for produce high-value crops. this system were designed of two parts that one part is measure and control unit, another part is server part for database and server side control. the main controller for measurement and control is used MC9S08AW60, server for Database and server-side control was using MySQL with CentOS. The source code of control program was coding C and compile with GCC. the functions of measurement and control unit are digital input and output each 8channels and can be scan-able of 20 Bit with 2CH/Sec. Analog Output were designed that can be output of 4-20mA or 0-5V on 4channel. The Digital input and output part were designed 8-channel, and using the high speed photo coupler and relays. We showed that system is possible to measure a 20bit data width, 2Ch/sec as 8 channel analog signals.

A Study on the Testing Method of IEC 61850 based Merging Unit (IEC 61850 기반 디지털 변전시스템의 머징유닛 시험방법에 관한 연구)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.41-47
    • /
    • 2009
  • The power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is going on how to perform the verification of a IEC 61850 based Merging Unit for development of the full Substation Automation system from station bus to process bus. the testing method that this paper suggests, is including the conformance testing of IEC 61850 communication services and transmission functions of digital sampled values such as current and voltage, and referring to IEC 61850 conformance testing of IED. And finally, the paper shows a test system for the Merging Unit.

Real-Time Monitoring for Automobile Rubber Parts Manufacturing (방진고무 생산공정의 실시간 모니터링)

  • 정광조;임선종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.653-657
    • /
    • 2000
  • The paper describes the contents and results of the national project named "Development of Computer Integrated Product Design for Automation Equipment". It is focussed on the real-time control '||'&'||' monitoring of manufacturing process for automobile rubber parts. Automobile rubber parts industy is one of the typical process that high11 depends upon manufacturing facilities and equipments. So. it requires high cost and engineering technolog) on plant implementation. But most companies of rubber parts industries are small or mid companies that habe weak abilities for plant implementation properly and systematically. Therefore, for upgrading the levelof automation. it is necessar). to dekelope the computer based management and monitoring slsteni that enables to build-up the common base of automation and systemization. 'Through this project. we developed low cost real-time monitoring system for banbun mixing process '||'&'||' mold injection process of rubbcr parts manufacturing, that is composed with DDCU(Distributed Digital Control Unit),signal interfaces to gathering mon~toring terms and speciall\ developed functional sofhare including some algorithm for management '||'&'||' process monitoring

  • PDF

An Improved Defect Detection Algorithm of Jean Fabric Based on Optimized Gabor Filter

  • Ma, Shuangbao;Liu, Wen;You, Changli;Jia, Shulin;Wu, Yurong
    • Journal of Information Processing Systems
    • /
    • v.16 no.5
    • /
    • pp.1008-1014
    • /
    • 2020
  • Aiming at the defect detection quality of denim fabric, this paper designs an improved algorithm based on the optimized Gabor filter. Firstly, we propose an improved defect detection algorithm of jean fabric based on the maximum two-dimensional image entropy and the loss evaluation function. Secondly, 24 Gabor filter banks with 4 scales and 6 directions are created and the optimal filter is selected from the filter banks by the one-dimensional image entropy algorithm and the two-dimensional image entropy algorithm respectively. Thirdly, these two optimized Gabor filters are compared to realize the common defect detection of denim fabric, such as normal texture, miss of weft, hole and oil stain. The results show that the improved algorithm has better detection effect on common defects of denim fabrics and the average detection rate is more than 91.25%.

A Neutral-Point Voltage Balance Controller for the Equivalent SVPWM Strategy of NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2109-2118
    • /
    • 2016
  • Based on the space vector pulse width modulation (SVPWM) theory, this paper realizes an easier SVPWM strategy, which is equivalently implemented by CBSPWM with zero-sequence voltage injection. The traditional SVPWM strategy has no effect on controlling the neutral-point voltage balance. In order to solve the neutral-point voltage unbalance problem for neutral-point-clamped (NPC) three-level inverters, this paper proposes a neutral-point voltage balance controller. The proposed controller realizes controlling the neutral-point voltage balance by dynamically calculating the offset superimposed to the three-phase modulation waves of an equivalent SVPWM strategy. Compared with the traditional SVPWM strategy, the proposed neutral-point voltage balance controller has a strong ability to balance the neutral-point voltage, has good steady-state performance, improves the output waveforms quality and is easy for digital implementation. An experiment has been carried out on a NPC three-level inverter prototype based on a digital signal processor-complex programmable logic device (DSP-CPLD). The obtained experimental results verify the effectiveness of the proposed neutral-point voltage balance controller.

DSP Based Series-Parallel Connected Two Full-Bridge DC-DC Converter with Interleaving Output Current Sharing

  • Sha, Deshang;Guo, Zhiqiang;Lia, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.673-679
    • /
    • 2010
  • Input-series-output-parallel (ISOP) connected DC-DC converters enable low voltage rating switches to be used in high voltage input applications. In this paper, a DSP is adopted to generate digital phase-shifted PWM signals and to fulfill the closed-loop control function for ISOP connected two full-bridge DC-DC converters. Moreover, a stable output current sharing control strategy is proposed for the system, with which equal sharing of the input voltage and the load current can be achieved without any input voltage control loops. Based on small signal analysis with the state space average method, a loop gain design with the proposed scheme is made. Compared with the conventional IVS scheme, the proposed strategy leads to simplification of the output voltage regulator design and better static and dynamic responses. The effectiveness of the proposed control strategy is verified by the simulation and experimental results of an ISOP system made up of two full-bridge DC-DC converters.

Development of a Digital Home Electric Overload Alarm Performance Evaluation System for Smart Home Automation (스마트 주택 자동화를 위한 주택 전기과부하 경보 성능 평가 시스템 개발)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.339-344
    • /
    • 2019
  • In this paper, a digital home electric overload alarm system based on DSP for smart home automation which can minimize electrical fire damage caused by an home electrical overload was made experimentally. To verify the validity of the home electrical overload alarm technology, an electric overload alarm performance evaluation system which can artificially generate the electrical overloads was designed, developed, and constructed, and the effectiveness of the overload alarm developed by the overload test was verified. In particular, an overload test EMTP model based on EMTP-RV was developed, and simulation and measurement results obtained from the overload test were compared, and the reliability of overload performance verification results was confirmed.

A System Architecture for Facility Fault Diagnosis and Repair Action in Smart Factory (스마트 팩토리에서 설비 장애 진단 및 조치 시스템 구조)

  • Cho, Jaehyung;Lee, Jaeoh
    • KNOM Review
    • /
    • v.23 no.1
    • /
    • pp.18-25
    • /
    • 2020
  • Recently, a research on a smart factory was developed from a concept of factory automation(FA) to the formation of collecting and analyzing data. This trend is accelerated as the development of communication technology(5G) and IoT devices are developed in various ways according to the field situation. In addition, digital transformation has been actively conducted in the strengthening corporate competitiveness, and various optimization studies are being conducted through process re-adjustment by combining data received from various IoT equipment and automated facilities. Therefore, in this paper, we propose a system architecture and its related components in diagnosing and repairing facility failure using a prediction system which is one of the related researches.

The Application of Fuzzy Reaching Law Control in AC Position Servo System

  • Yang Yangxi;Liu Ding
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.360-364
    • /
    • 2001
  • In this paper, a novel method of reaching law variable structure control based on fuzzy rules is present, which is that the reaching law parameters is on-line adjusted by fuzzy rules. This method is used in a digital ac position servo system, the experiment results show that the system designed by this method has both satisfactory quality and very smaller chattering.

  • PDF

The Analysis of Characteristics of GMAW using Sound Signal (음향 신호 분석에 의한 GMAW의 특성분석)

  • 조택동;양상민;양성빈
    • Proceedings of the KWS Conference
    • /
    • 2002.05a
    • /
    • pp.65-67
    • /
    • 2002
  • The gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance of weld automation. The measured analog signal is frequency analyzed by digital signal process method. In order to observe the welding phenomena and control welding condition, arc light, voltage, and current are measured at the same time. They are analyzed and compared with arc sound. for these experiments, a power source of constant voltage characteristics was used in the pure metal transfer mode.

  • PDF