• Title/Summary/Keyword: Diffractive optical element

Search Result 48, Processing Time 0.029 seconds

Correction of image distortion of CGH with a large diffraction angle (큰 회절각을 가진 CGH의 위치에 대한 오차의 보정)

  • Lee, Jai-Cheol;Oh, Yong-Ho;Go, Chun-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.2
    • /
    • pp.128-132
    • /
    • 2005
  • Most CGH programs use a model equation based on the diffraction angle. Therefore, if the diffraction angle is large enough, the image on a flat screen is distorted. To correct the distortion, we created the model equation from diffraction theory and verified it through experiment. We also suggest a design method that compensates for the distortion without changing the CGH program.

Squint-less Phased Array Antenna Near-field Subwavelength Focusing with True-time Optical Delay Line (광 지연선로를 이용한 스퀸팅이 없는 위상배열 안테나의 근접장 서브파장 포커싱)

  • Jung, Young Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.3
    • /
    • pp.94-100
    • /
    • 2019
  • The near-field subwavelength squint-less focusing system of a phased array antenna is designed and demonstrated by numerical simulation. The Huygens-Fresnel principle is applied to numerical simulation for calculation of the phased array antenna at microwave frequency. It was shown that beam squinting can be eliminated, utilizing true-time optical delay lines based on a chirped fiber grating in the proposed system. Furthermore, subwavelength focusing with high numerical aperture can be achieved by considering the fact that the array elements of the phased-array antenna can be treated as diffractive elements in an optical lens system. Also, side lobes can be suppressed by decreasing the distance between element antennas to less than half of the wavelength.

The comparison and the Analysis of the optical performances between the single and the symmetrical double DOE lenses (단매와 대칭 2매로 구성된 DOE 렌즈의 광학성능 비교 및 분석)

  • 이환선;임천석;조재홍
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.258-265
    • /
    • 2002
  • In this paper, we design single and symmetrical double lenses with DOE. The specifications are the following : Image area is 4.8 mm $\times$ 3.6 mm, F/# is 2.8 and the overall length (from first lens surface to image plane) is 6.8mm. After comparing the optical performance and characteristic values, we determine that symmetrical double lenses are superior to single lenses. Symmetrical double lenses have the merits of fewer zones, weaker flare, and smaller distortion than single lenses.

Fast Noise Reduction Approach in Multifocal Multiphoton Microscopy Based on Monte-Carlo Simulation

  • Kim, Dongmok;Shin, Younghoon;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.421-430
    • /
    • 2021
  • The multifocal multiphoton microscopy (MMM) enables high-speed imaging by the concurrent scanning and detection of multiple foci generated by lenslet array or diffractive optical element. The MMM system mainly suffers from crosstalk generated by scattered emission photons that form ghost images among adjacent channels. The ghost image which is a duplicate of the image acquired in sub-images significantly degrades overall image quality. To eliminate the ghost image, the photon reassignment method was established using maximum likelihood estimation. However, this post-processing method generally takes a longer time than image acquisition. In this regard, we propose a novel strategy for rapid noise reduction in the MMM system based upon Monte-Carlo (MC) simulation. Ballistic signal, scattering signal, and scattering noise of each channel are quantified in terms of photon distribution launched in tissue model based on MC simulation. From the analysis of photon distribution, we successfully eliminated the ghost images in the MMM sub-images. If the priori MC simulation under a certain optical condition is established at once, our simple, but robust post-processing technique will continuously provide the noise-reduced images, while significantly reducing the computational cost.

Measurement of a Six-degree-of-freedom Dynamic Characteristics using Angle Sensor-Implemented Grating Interferometry (회절격자 간섭계를 이용한 초정밀 스테이지의 6 자유도 운동 특성 측정)

  • Lee, Cha-Bum;Kim, Gyu-Ha;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.906-912
    • /
    • 2012
  • This paper presents the new method for a six-degree-of-freedom (DOF) motion measurement and those dynamic characterizations in an ultraprecision linear stage using angle sensor-implemented grating interferometry. It consists of a diffractive optical element, a corner cube, four separate two-dimensional position sensitive detectors, four photodiodes and auxiliary optics components. From the previous study, it was confirmed that the proposed optical system could measure a six-DOF motion error in a linear stage. In this article, six-DOF motion dynamic characteristics of the stage were investigated through the step response and with respect to the conditions with a different speed of a slide table. As a result, the natural frequency and damping ratio according to a six-DOF direction was obtained. Also, it was seen that the speed of slide table had an significant effect on a six-DOF displacement motion, especially, X, which was considered as the effect of friction mechanism and local elastic mechanical deformation in a slide guide.

In Vivo and Ex Vivo Skin Reactions after Multiple Pulses of 1,064-nm, Microlens Array-type, Picosecond Laser Treatment

  • Lyu, Herin;Park, Jinyoung;Lee, Hee Chul;Lee, Sang Ju;Kim, Young Koo;Cho, Sung Bin
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.142-149
    • /
    • 2020
  • Background and Objectives A picosecond-domain laser treatment using a microlens array (MLA) or a diffractive optical element elicits therapeutic micro-injury zones in the skin. This study examined the patterns of tissue reactions after delivering multiple pulses of 1,064-nm, MLA-type, picosecond neodymium:yttrium-aluminum-garnet laser treatment. Materials and Methods Multiple pulses of picosecond laser treatment were delivered to ex vivo human or brown micropig skin and analyzed histopathologically. A high-speed cinematographic study was performed to visualize the multiple pulses of picosecond laser energy-induced skin reactions in in vivo human skin. Results In the ex vivo human skin, a picosecond laser treatment at a fluence of 0.3 J/cm2 over 100 non-stacking passes generated multiple lesions of thermally-initiated laser-induced optical breakdown (TI-LIOB) in the epidermis and dermis. In the ex vivo micropig skin, stacking pulses of 20, 40, 60, 80, and 100 at a fluence of 0.3 J/cm2 generated distinct round to oval zones of tissue coagulation in the mid to lower dermis. High-speed cinematography captured various patterns of twinkling, micro-spot reactions on the skin surface over 100 stacked pulses of a picosecond laser treatment. Conclusion Multiple pulses of 1,064-nm, MLA-type, picosecond laser treatment elicit marked TI-LIOB reactions in the epidermis and areas of round to oval thermal coagulation in the mid to deep dermis.

High-Quality Stereo Depth Map Generation Using Infrared Pattern Projection

  • Jeong, Jae-Chan;Shin, Hochul;Chang, Jiho;Lim, Eul-Gyun;Choi, Seung Min;Yoon, Kuk-Jin;Cho, Jae-Il
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.1011-1020
    • /
    • 2013
  • In this paper, we present a method for obtaining a high-quality 3D depth. The advantages of active pattern projection and passive stereo matching are combined and a system is established. A diffractive optical element (DOE) is developed to project the active pattern. Cross guidance (CG) and auto guidance (AG) are proposed to perform the passive stereo matching in a stereo image in which a DOE pattern is projected. When obtaining the image, the CG emits a DOE pattern periodically and consecutively receives the original and pattern images. In addition, stereo matching is performed using these images. The AG projects the DOE pattern continuously. It conducts cost aggregation, and the image is restored through the process of removing the pattern from the pattern image. The ground truth is generated to estimate the optimal parameter among various stereo matching algorithms. Using the ground truth, the optimal parameter is estimated and the cost computation and aggregation algorithm are selected. The depth is calculated and bad-pixel errors make up 4.45% of the non-occlusion area.

Micro Groove Cutting Using Diamond Tools (다이아몬드 공구를 이용한 미세 홈 가공)

  • Choi, Young Jae;Song, Ki Hyeong;Lee, Seok Woo;Choi, Hon Zong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.3
    • /
    • pp.181-187
    • /
    • 2014
  • Micro patterns are used to maximize the performance and efficiency of the product in many industries such as energy, display, printing, biology, etc. Nowadays, the fabrication technology for micro patterns has been developed in various ways such as photolithography, laser machining, electrical discharge machining and mechanical machining. Recently, mechanical machining the size of smaller than 1 micrometer could be tried, because the technology related to the machining was developed brilliantly. This paper shows the experiments using cutting processes in order to fabricate the micro pattern. Micro patterns of the size of several micrometers were machined by the diamond tools of two different shape, the deformation and generation of burr were investigated.