• Title/Summary/Keyword: Differential operation

Search Result 450, Processing Time 0.027 seconds

Face Image Analysis using Adaboost Learning and Non-Square Differential LBP (아다부스트 학습과 비정방형 Differential LBP를 이용한 얼굴영상 특징분석)

  • Lim, Kil-Taek;Won, Chulho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.6
    • /
    • pp.1014-1023
    • /
    • 2016
  • In this study, we presented a method for non-square Differential LBP operation that can well describe the micro pattern in the horizontal and vertical component. We proposed a way to represent a LBP operation with various direction components as well as the diagonal component. In order to verify the validity of the proposed operation, Differential LBP was investigated with respect to accuracy, sensitivity, and specificity for the classification of facial expression. In accuracy comparison proposed LBP operation obtains better results than Square LBP and LBP-CS operations. Also, Proposed Differential LBP gets better results than previous two methods in the sensitivity and specificity indicators 'Neutral', 'Happiness', 'Surprise', and 'Anger' and excellence Differential LBP was confirmed.

Unknown Inputs Observer Design Via Block Pulse Functions

  • Ahn, Pius
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.3
    • /
    • pp.205-211
    • /
    • 2002
  • Unknown inputs observer(UIO) which is achieved by the coordinate transformation method has the differential of system outputs in the observer and the equation for unknown inputs estimation. Generally, the differential of system outputs in the observer can be eliminated by defining a new variable. But it brings about the partition of the observer into two subsystems and need of an additional differential of system outputs still remained to estimate the unknown inputs. Therefore, the block pulse function expansions and its differential operation which is a newly derived in this paper are presented to alleviate such problems from an algebraic form.

A Percentage Differential Current Relaying Algorithm for Bus Protection Using Current Transformer Saturation Detecting Algorithm (변류기 포화검출 알고리즘을 적용한 모선보호용 비율전류차동 계전방식)

  • Kang, Yong-Cheol;Yun, Jae-Sung;Ok, Seung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.115-117
    • /
    • 2001
  • A percentage current differential relaying algorithm is widely used for bus protection. However, it may maloperate external faults with CT saturation. This paper proposes a percentage current differential relaying algorithm for bus protection using CT saturation detecting algorithm. The CT saturation detecting algorithm uses difference of secondary current of CT and detects CT saturation. The proposed method distinguishes percentage differential relay operation caused by faults from percentage differential relay operation caused by CT saturations.

  • PDF

Analysis of Linear System by using Block Pulse function's Differential Operation (블럭펄스 함수 미분 연산식을 이용한 시스템 해석에 관한 연구)

  • Ahni, Pius;Sim, J.S.;Chae, Y.M.;Ahn, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.581-583
    • /
    • 1997
  • For the last two decades, many researchers have interests in orthogonal functions by reason of its applicability on linear system analysis. But they only used integral operation matrix of orthogonal functions to solve the state space equations. Thus, this paper present some new result of differential operation of block-pulse functions from a numerical point of view.

  • PDF

Enhanced Common-Mode Noise Rejection Method Based on Impedance Mismatching Compensation for Wireless Capsule Endoscopy Systems

  • Hwang, Won-Jun;Kim, Ki-Yun;Choi, Hyung-Jin
    • ETRI Journal
    • /
    • v.37 no.3
    • /
    • pp.637-645
    • /
    • 2015
  • Common-mode noise (CMN) is an unresolved problem in wireless capsule endoscopy (WCE) systems. In a WCE system, CMN originates from various electric currents found within the human body or external interference sources and causes critical demodulation performance degradation. The differential operation, a typical method for the removal of CMN rejection, can remove CMN by subtracting two signals simultaneously received by two reception sensors attached to a human body. However, when there is impedance mismatching between the two reception sensors, the differential operation method cannot completely remove CMN. Therefore, to overcome this problem, we propose an enhanced CMN rejection method. The proposed method performs not only subtraction but also addition between two received signals. Then a CMN ratio can be estimated by sufficient accumulation of division operation outcomes between the subtraction and addition outputs during the guard period. Finally, we can reject the residual CMN by combining the subtraction and addition outputs.

A GENERALIZATION OF DIFFERENTIAL FORMS AND ITS APPLICATION

  • Shikata, Yoshihiro;Hong, Suk-Ho
    • Bulletin of the Korean Mathematical Society
    • /
    • v.28 no.2
    • /
    • pp.225-229
    • /
    • 1991
  • Our final purpose may be to introduce generalized differential forms on the space Map(S, M) of mappings from a manifold S into a manifold M and discuss the differential geometry of the space Map(S, M) from the point of the generalized forms. Here we take a subspace X of the space Map(S,M) and we introduce the generalized differential forms on X, taking the dual to the chain space with the flat norm. This method of construction allows us to discuss a sufficient condition for a subspace Y of X to admit the generalized differential forms and the natural integration as the dual operation.

  • PDF

The Design of Model Reference Adaptive Controller via Block Pulse Functions (블럭펄스 함수를 이용한 기준 모델 적응 제어기 설계)

  • Kim, Jin-Tae;Kim, Tai-Hoon;Lee, Myung-Kyu;Ahn, Doo-Soo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • This paper proposes a algebraic parameter determination of MRA(Model Reference Adaptive Control) controller using block Pulse functions and block Pulse function's differential operation. Generally, adaption is performed by solving differential equations which describe adaptive low for updating controller parameter. The proposes algorithm transforms differential equations into algebraic equation, which can be solved much more easily inn a recursive manner. We believe that proposes methods are very attractive and proper for parameter estimation of MRAC controller on account of its simplicity and computational convergence.

A Fully-Differential Correlated Doubling Sampling Readout Circuit for Mutual-capacitance Touch Screens

  • Kwon, Kihyun;Kim, Sung-Woo;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.349-355
    • /
    • 2015
  • A fully-differential touch-screen sensing architecture is presented to improve noise immunity and also support most multi-touch events minimizing the number of amplifiers and their silicon area. A correlated double sampling function is incorporated to reduce DC offset and low-frequency noises, and a stabilizer circuit is also embedded to minimize inherent transient fluctuations. A prototype of the proposed readout circuit was fabricated in a $0.18{\mu}m$ CMOS process and its differential operation in response to various touch events was experimentally verified. With a 3.3 V supply, the current dissipation was 3.4 mA at normal operation and $140{\mu}A$ in standby mode.

The Experimental Study on the Leakage of Automatic Pressure Differential·Overpressure Control Dampers by Increasing the Number of Damper Operation (자동차압·과압조절형댐퍼의 개폐동작횟수 증가에 따른 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.56-61
    • /
    • 2016
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of above 40 Pa, but pressure differential is excessively overpressure in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by increasing the number of dampers operation for identifying this problems. The result of testing, the leakage has difference between new dampers and increased the number of operation dampers. As the static preassure increase, the leakage difference increase. Comparison with preceding study, this result has similar linear tendency.

Digital Ratio Differential Relaying for Main Protection of Large Generator (대형 발전기 주보호를 위한 디지털 비율차동 계전기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • An AC generator is an important component in producing an electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. It is a need for research of digital generator protection system(DGPS) for the next-generation ECMS and an efficient operation of protection control system in power station. However, most of protection and control system used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, presented ratio differential relaying(RDR) is main protective element in generator protection IED. The fault detection technique, operation zone and setting value of the RDR were studied and, compared with two of the fault detection algorithm. For evaluation performance of the RDR, the data obtained from ATPDraw5.7p4 modeling was used. The proposed methods are shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault.