Browse > Article
http://dx.doi.org/10.4218/etrij.15.0114.1322

Enhanced Common-Mode Noise Rejection Method Based on Impedance Mismatching Compensation for Wireless Capsule Endoscopy Systems  

Hwang, Won-Jun (Samsung Electronics Co. Ltd.)
Kim, Ki-Yun (Department of Information and Engineering, Myongji College)
Choi, Hyung-Jin (College of Information and Communication Engineering, Sungkyunkwan University)
Publication Information
ETRI Journal / v.37, no.3, 2015 , pp. 637-645 More about this Journal
Abstract
Common-mode noise (CMN) is an unresolved problem in wireless capsule endoscopy (WCE) systems. In a WCE system, CMN originates from various electric currents found within the human body or external interference sources and causes critical demodulation performance degradation. The differential operation, a typical method for the removal of CMN rejection, can remove CMN by subtracting two signals simultaneously received by two reception sensors attached to a human body. However, when there is impedance mismatching between the two reception sensors, the differential operation method cannot completely remove CMN. Therefore, to overcome this problem, we propose an enhanced CMN rejection method. The proposed method performs not only subtraction but also addition between two received signals. Then a CMN ratio can be estimated by sufficient accumulation of division operation outcomes between the subtraction and addition outputs during the guard period. Finally, we can reject the residual CMN by combining the subtraction and addition outputs.
Keywords
Body area network; CMN; differential signaling; impedance mismatching; WCE;
Citations & Related Records
연도 인용수 순위
  • Reference
1 B. Chi et al., "A 2.4 GHz Low-Power Wireless Transceiver Analog Front-End for Endoscopy Capsule System," IEEE Int. Symp. Circuits Syst., Island of Kos, Greece, May 21-24, 2006, pp. 4907-4910.
2 G. Iddan et al., "Wireless Capsule Endoscopy," Nature, vol. 405, May 2000, pp. 417-418.
3 S.H. Lee et al., "A Wideband Spiral Antenna for Ingestible Capsule Endoscope Systems: Experimental Results in a Human Phantom and a Pig," IEEE Trans. Biomed. Eng., vol. 58, no. 6, June 2011, pp. 1734-1741.   DOI
4 K.-Y. Kim et al., "A Comparison of Communication Techniques for Capsule Endoscopes," IEEE APCC, Sabah, Malaysia, Oct. 2-5, 2011, pp. 761-764.
5 K. Nagata and Y. Kado, "Analysis of Transmission Quality in Technology for In-Body to Off-Body MHz Band near Field Coupling Communication," EuCAP, Gothenburg, Sweden, Apr. 8-12, 2013, pp. 789-793.
6 M. Ahmadian et al., "Data Transmission for Implantable Microsystems Using Magnetic Coupling," IEE Commun., Apr. 2005, pp. 247-250.
7 K. Kim et al., "A Design of a High-Speed and High-Efficiency Capsule Endoscopy System," IEEE Trans. Biomed. Eng., vol. 59, no. 4, Apr. 2012, pp. 1005-1011.   DOI
8 R. Nagai et al., "Near-Field Coupling Communication Technology for Human-Area Networking," Systemics, Cybern. Informat., vol. 10, no. 6, 2012, pp. 14-18.
9 N. Vidal et al., "Detuning Study of Implantable Antennas Inside the Human Body," Electromagn. Res., vol. 124, 2012, pp. 265-283.   DOI
10 M. Shinagawa et al., "Noise Analysis for Intra-body Communication Based on Parasitic Capacitance Measurement," Meas., vol. 51, May 2014, pp. 206-213.   DOI
11 A. Sasaki et al., "Signal-to-Noise Ratio Analysis of a NoisyChannel Model for a Capacitively Coupled Personal Area Network," IEEE Trans. Antennas Propag., vol. 61, no. 1, Sept. 2012, pp. 390-402.   DOI
12 M.K. Simon and M.-S. Alouini, "Digital Communication over Fading Channels: A Unified Approach to Performance Analysis," 2nd ed., New York, NY, USA: Wiley, 2005.
13 M. Sendoh, K. Ishiyama, and K.-I. Arai, "Fabrication of Magnetic Actuator for Use in a Capsule Endoscope," IEEE Trans. Magn., vol. 39, no. 5, Sept. 2003, pp. 3232-3234.   DOI