• Title/Summary/Keyword: Dew point temperature

Search Result 133, Processing Time 0.03 seconds

Forecasting Advection Fog at Busan Area in the Month of July (7월의 부산지방의 이류무예보에 관하여)

  • 한영호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.9 no.1
    • /
    • pp.19-23
    • /
    • 1973
  • The method of forecasting advection fog at Busan area in July is developed using the Spreen's scatter-diagraam technique. The used Parameters are (1) air temperature (2) dew-point temperature, (3) sea surface temperature (4) resultantt wind direction (5) resultant wind speed in Busan. The skill score and the pcr cent correct based on 4 yeare of dependent data are 0.79 and 90.3% respectively.

  • PDF

An Experimental Study of Frost Formation on the Horizontal Cylinder (수평 실린더 표면의 착상에 대한 실험적 연구)

  • Paik, Sang-Jin;Lee, Yoon-Been;Ro, Sung-Tack
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF

An Experimental Study on the Evaluation of Fastening Unit Insulation Developed for the Insulation of Curtain Wall

  • Kim, Bong-Joo;Kim, Kyeong-A
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.2
    • /
    • pp.243-256
    • /
    • 2012
  • This study is the experimental study to improve the insulation of the fastening unit system, which has the most vulnerable insulation in the curtain walls. The Fastening Units were designed and fabricated to minimize the connection part of mullions. In addition, slight movements were taken into account and the performance of the middle layer was evaluated by forming an insulation layer with the vibration-proof rubber and the silicon to satisfy the mechanical and thermal performance criteria. A total of 10 experiments were performed under various conditions, such as indoor-outdoor temperature difference, type of insulation material, thickness of insulation material, and others. using the fabricated Fastening Units. As a result, the vibration-proof rubber insulation showed the temperature difference of $2.2^{\circ}C-5.0^{\circ}C$, and the silicon insulation showed the temperature difference of $2.8^{\circ}C-4.5^{\circ}C$, compared to the non-insulated Fasteniirature difference, typesng Units. When these results were compared with the psychometric chart graph, the insulated Fastening Unit designed in this study can be considered to prevent the dew condensation.

A study on road ice prediction by applying road freezing evaluation model (도로 노면결빙 판정모델을 적용한 도로결빙 예측에 대한 연구)

  • Lim, Hee-Seob;Kim, Sang-Tae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1507-1516
    • /
    • 2020
  • This study analyzed the scenario for road freezing section by applying the road freezing evaluation algorithm. To apply road freezing algorithm, the influencing factors on road freezing were reviewed. Observation data from four points, Mokgam IC, Jeongneung tunnel, Seongsan bridge, and Yeomchang bridge were used for analysis. All observatories are installed on the expressway, and they are classified for the analysis of road freezing characteristics. When the difference between the road surface temperature and dew-point temperature of the road freezing evaluation algorithm was 3℃ or less, the section where road freezing occurred was checked. In addition, road freezing evaluation was derived through the change of the road surface condition and water film thickness of the freezing section.

Correlation Analysis of Meteorological Factors for Wooden Building in Beopjusa and Seonamsa Temples by Statistical Model (통계적 모형을 통한 법주사와 선암사 목조건축물의 기상인자에 대한 상관성 분석)

  • Kim, Young Hee;Kim, Myoung Nam;Lim, Bo A;Lee, Jeung Min;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.387-396
    • /
    • 2018
  • Exposure to the natural environment can cause damage to domestic wooden cultural assets, such as temples. Deterioration is accelerated by biological damage and various environmental factors. In this study, meteorological factors were monitored by equipment installed at Beopjusa temple of Boeun province and Seonamsa temple of Suncheon province. A statistical model was applied to these data to predict the meteorological factors and to compare the predictive performance of each meteorological factor. The resulting correlation coefficient between air and dew point temperatures was highest, at 0.95, while the correlation coefficient for relative humidity had a moderate value(0.65) at both the Beopjusa and Seonamsa temples. Thus, a general linear model was found to be suitable for predicting air and dew point temperatures. An analysis of correlation between meteorological factors showed that there was strong positive correlation between air temperature and dew point temperature, and between solar radiation and evaporation at both sites. There was a weak positive correlation between air temperature and evaporation at Beopjusa temple. Wind speed was negatively correlated with both air temperature and relative humidity at Seonamsa temple. The wind speed at this location is higher than average in winter and lower than average in summer, and it was hypothesized that the low wind speed plays a role in reducing water evaporation in summer, when both air temperature and relative humidity are high. As a result, damage to the wooden buildings of Seonamsa temple is accelerated.

The Study of Thyristor Valve Water Cooling Control Systems (대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구)

  • 임익헌;류호선
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

An Experimental Study on the Performance of Heat Pump Air Conditioner according to Frequency Modulator for Cooling and Heating (주파수변조장치를 이용한 열펌프식 공기조화기의 냉방-난방에 관한 실험적 연구)

  • Lee, Dae Woo;Cho, Jin Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.203-209
    • /
    • 1989
  • This paper is an experimental study on the pleasantly suitable cool/warm air conditioning system in order to minimize the energy consumption by attaching the electronic-controlled device to the heat pump air conditioning system.While the cool/warm air conditioning, the air temperatures in the entrance and exit of the indoor heat exchangers should be checked and when the surface of heat exchanger is reached to the dew point temperature, a speed of the compressor is to be automatically controlled by anti-dewing system in order to minimize the energy consumption.At the result of this study, the energy consuming amount is saved about 5% more than that of the conventional air conditioning system by prevent unnecessary dew forming.

  • PDF

Study on the Estimation of Frost Occurrence Classification Using Machine Learning Methods (기계학습법을 이용한 서리 발생 구분 추정 연구)

  • Kim, Yongseok;Shim, Kyo-Moon;Jung, Myung-Pyo;Choi, In-tae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.86-92
    • /
    • 2017
  • In this study, a model to classify frost occurrence and frost free day was developed using the digital weather forecast data provided by Korea Meteorological Administration (KMA). The minimum temperature, average wind speed, relative humidity, and dew point temperature were identified as the meteorological variables useful for classification frost occurrence and frost-free days. It was found that frost-occurrence date tended to have relatively low values of the minimum temperature, dew point temperature, and average wind speed. On the other hand, relatively humidity on frost-free days was higher than on frost-occurrence dates. Models based on machine learning methods including Artificial Neural Network (ANN), Random Forest(RF), Support Vector Machine(SVM) with those meteorological factors had >70% of accuracy. This results suggested that these models would be useful to predict the occurrence of frost using a digital weather forecast data.

Impact of Tidal Effects on Fog Events in the Western Coast of Korea (서해 연안 해역에서의 조석현상이 안개에 미치는 영향)

  • An, Hye Yeon;Jeong, Ju-Hee;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.30 no.11
    • /
    • pp.925-936
    • /
    • 2021
  • The study was aimed to investigate the correlation between tidal effects and fog occurrence in Incheon and Mokpo, which are located in the middle and southern coasts of the West Sea of Korea, respectively. The investigation used meteorological data obtained from the automated synoptic observing systems and automatic weather stations and ocean data from tide stations from 2010 to 2019. Fog occurrence frequency was highest at high tide (Incheon, 41%; Mokpo, 45%). During fog event days at high tide, the dew-point depression was low (Incheon, 0.5℃; Mokpo, 0.4℃) and the relative humidity was high (Incheon, 97%; Mokpo, 98%). The wind speed was 2.4 m/s in Incheon and 2.0 m/s in Mokpo, and the main wind directions were west-southwesterly from Incheon and southwesterly from Mokpo. In the fog case study, tidal flats were covered with water before and after the fog started. During the fog period, both stations experienced negative air-sea temperature differences, low dew-point depression, and high relative humidity were maintained, with weak winds forming from the tidal flats to the shore.

Comparisons of Collection 5 and 6 Aqua MODIS07_L2 air and Dew Temperature Products with Ground-Based Observation Dataset (Collection 5와 Collection 6 Aqua MODIS07_L2 기온과 이슬점온도 산출물간의 비교 및 지상 관측 자료와의 비교)

  • Jang, Keunchang;Kang, Sinkyu;Hong, Suk Young
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.571-586
    • /
    • 2014
  • Moderate Resolution Imaging Spectroradiometer (MODIS) provides air temperature (Tair) and dew point temperature (Tdew) profiles at a spatial resolution of 5 km. New Collection 6 (C006) MODIS07_L2 atmospheric profile product has been produced since 2012. The Collection 6 algorithm has several modifications from the previous Collection 5 (C005) algorithm. This study evaluated reliabilities of two alternative datasets of surface-level Tair and Tdew derived from C005 and C006 Aqua MODIS07_L2 (MYD07_L2) products using ground measured temperatures from 77 National Weather Stations (NWS). Saturated and actual vapor pressures were calculated using MYD07_L2 Tair and Tdew. The C006 Tair showed lower mean error (ME, -0.76 K) and root mean square error (RMSE, 3.34 K) than the C005 Tair (ME = -1.89 K, RMSE = 4.06 K). In contrasts, ME and RMSE of C006 Tdew were higher than those (ME = -0.39 K, RMSE = 5.65 K) of C005 product. Application of ambient lapse rate for Tair showed appreciable improvements of estimation accuracy for both of C005 and C006, though this modification slightly increased errors in C006 Tdew. The C006 products provided better estimation of vapor pressure datasets than the C005-derived vapor pressure. Our results indicate that, except for Tdew, C006 MYD07_L2 product showed better reliability for the region of South Korea than the C005 products.