• 제목/요약/키워드: Dew point temperature

검색결과 133건 처리시간 0.035초

7월의 부산지방의 이류무예보에 관하여 (Forecasting Advection Fog at Busan Area in the Month of July)

  • 한영호
    • 수산해양기술연구
    • /
    • 제9권1호
    • /
    • pp.19-23
    • /
    • 1973
  • The method of forecasting advection fog at Busan area in July is developed using the Spreen's scatter-diagraam technique. The used Parameters are (1) air temperature (2) dew-point temperature, (3) sea surface temperature (4) resultantt wind direction (5) resultant wind speed in Busan. The skill score and the pcr cent correct based on 4 yeare of dependent data are 0.79 and 90.3% respectively.

  • PDF

수평 실린더 표면의 착상에 대한 실험적 연구 (An Experimental Study of Frost Formation on the Horizontal Cylinder)

  • 백상진;이윤빈;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF

An Experimental Study on the Evaluation of Fastening Unit Insulation Developed for the Insulation of Curtain Wall

  • Kim, Bong-Joo;Kim, Kyeong-A
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.243-256
    • /
    • 2012
  • This study is the experimental study to improve the insulation of the fastening unit system, which has the most vulnerable insulation in the curtain walls. The Fastening Units were designed and fabricated to minimize the connection part of mullions. In addition, slight movements were taken into account and the performance of the middle layer was evaluated by forming an insulation layer with the vibration-proof rubber and the silicon to satisfy the mechanical and thermal performance criteria. A total of 10 experiments were performed under various conditions, such as indoor-outdoor temperature difference, type of insulation material, thickness of insulation material, and others. using the fabricated Fastening Units. As a result, the vibration-proof rubber insulation showed the temperature difference of $2.2^{\circ}C-5.0^{\circ}C$, and the silicon insulation showed the temperature difference of $2.8^{\circ}C-4.5^{\circ}C$, compared to the non-insulated Fasteniirature difference, typesng Units. When these results were compared with the psychometric chart graph, the insulated Fastening Unit designed in this study can be considered to prevent the dew condensation.

도로 노면결빙 판정모델을 적용한 도로결빙 예측에 대한 연구 (A study on road ice prediction by applying road freezing evaluation model)

  • 임희섭;김상태
    • 한국응용과학기술학회지
    • /
    • 제37권6호
    • /
    • pp.1507-1516
    • /
    • 2020
  • 본 연구는 도로 노면결빙 판정 알고리즘을 적용하여 도로결빙 구간에 대한 시나리오를 분석하였다. 도로결빙 알고리즘 적용을 위해서, 도로 결빙에 대한 영향인자를 검토하고, 분석을 위해서 목감IC, 정릉터널, 성산대교, 염창교 등 4지점의 관측자료를 활용하였다. 관측소는 모두 고속화도로에 설치되어 있으며, 도로 결빙 특성 분석을 위하여 분류하였다. 도로 결빙 판정 알고리즘의 노면온도-노점온도 차가 3℃ 이하일 때 도로결빙 발생 구간을 확인하고 결빙 구간의 노면상태와 수막두께 변화를 통해 도로 결빙 판정을 도출하였다.

통계적 모형을 통한 법주사와 선암사 목조건축물의 기상인자에 대한 상관성 분석 (Correlation Analysis of Meteorological Factors for Wooden Building in Beopjusa and Seonamsa Temples by Statistical Model)

  • 김영희;김명남;임보아;이정민;박지희
    • 보존과학회지
    • /
    • 제34권5호
    • /
    • pp.387-396
    • /
    • 2018
  • 국내 목조건축문화재는 자연환경에 그대로 노출되어 있어 생물피해와 여러 환경요인에 의해 피해가 가속화되고 있다. 이에 본 연구에서는 보은 법주사와 순천 선암사에 기상인자 모니터링을 위한 자동기상측정장비를 설치하여 기상데이터를 수집하였다. 이들 데이터에 통계 모형을 적용하여 기상인자를 예측하고 기상인자별 예측성능을 비교하였다. 그 결과, 법주사와 선암사 두 곳 모두에서 대기온도와 이슬점온도의 상관계수가 0.95 이상으로 가장 높게 나타났으며 상대습도의 상관계수는 0.65로 낮게 나타났다. 결과적으로 일반선형모형은 대기온도와 이슬점온도를 예측하기에 적합하다는 것을 확인하였다. 기상인자들 사이의 상관성을 분석한 결과, 법주사와 선암사 모두 대기온도와 이슬점온도, 일사량과 증발량 사이에 강한 양의 상관성을 보였으며, 법주사에서는 대기온도와 증발량이 약한 양의 상관성을 나타내었고 선암사에서는 풍속이 대기온도와 상대습도에 대하여 약한 음의 상관성을 나타내었다. 선암사의 풍속은 겨울에 높고 여름에 평균 이하로 낮아지는 패턴을 보이는데, 이것은 대기온도와 상대습도가 높은 여름철에 수분의 증발을 막고 정체시키는 역할을 하는 것으로 판단되며, 결과적으로 이것이 선암사의 목조건축물 피해를 가속화시키는 것으로 판단된다.

대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구 (The Study of Thyristor Valve Water Cooling Control Systems)

  • 임익헌;류호선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

주파수변조장치를 이용한 열펌프식 공기조화기의 냉방-난방에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Air Conditioner according to Frequency Modulator for Cooling and Heating)

  • 이대우;조진호
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.203-209
    • /
    • 1989
  • This paper is an experimental study on the pleasantly suitable cool/warm air conditioning system in order to minimize the energy consumption by attaching the electronic-controlled device to the heat pump air conditioning system.While the cool/warm air conditioning, the air temperatures in the entrance and exit of the indoor heat exchangers should be checked and when the surface of heat exchanger is reached to the dew point temperature, a speed of the compressor is to be automatically controlled by anti-dewing system in order to minimize the energy consumption.At the result of this study, the energy consuming amount is saved about 5% more than that of the conventional air conditioning system by prevent unnecessary dew forming.

  • PDF

기계학습법을 이용한 서리 발생 구분 추정 연구 (Study on the Estimation of Frost Occurrence Classification Using Machine Learning Methods)

  • 김용석;심교문;정명표;최인태
    • 한국농림기상학회지
    • /
    • 제19권3호
    • /
    • pp.86-92
    • /
    • 2017
  • 본 연구에서는 기상청 예보자료를 이용할 것을 전제로 서리가 발생하는 날과 서리가 발생하지 않는 날을 구분하는 모형을 구축하였다. 서리가 발생한 날과 서리가 발생하지 않은 날을 구분할 수 있는 기상인자로서 최저기온, 평균풍속, 평균상대습도, 평균이슬점온도로 나타났다. 기상인자별로 두 날을 비교한 결과 서리가 발생한 날이 서리가 발생하지 않은 날에 비해 최저기온, 이슬점온도, 평균풍속은 낮게 나타났고 상대습도는 높게 나타났다. 이러한 기상인자로 인공신경망, 랜덤포레스트, 서포트벡터 머신의 기계학습법을 이용한 모형을 연구한 결과 70%이상의 정확도를 나타내어 활용 가능성이 있을 것으로 판단된다.

서해 연안 해역에서의 조석현상이 안개에 미치는 영향 (Impact of Tidal Effects on Fog Events in the Western Coast of Korea)

  • 안혜연;정주희;김유근
    • 한국환경과학회지
    • /
    • 제30권11호
    • /
    • pp.925-936
    • /
    • 2021
  • The study was aimed to investigate the correlation between tidal effects and fog occurrence in Incheon and Mokpo, which are located in the middle and southern coasts of the West Sea of Korea, respectively. The investigation used meteorological data obtained from the automated synoptic observing systems and automatic weather stations and ocean data from tide stations from 2010 to 2019. Fog occurrence frequency was highest at high tide (Incheon, 41%; Mokpo, 45%). During fog event days at high tide, the dew-point depression was low (Incheon, 0.5℃; Mokpo, 0.4℃) and the relative humidity was high (Incheon, 97%; Mokpo, 98%). The wind speed was 2.4 m/s in Incheon and 2.0 m/s in Mokpo, and the main wind directions were west-southwesterly from Incheon and southwesterly from Mokpo. In the fog case study, tidal flats were covered with water before and after the fog started. During the fog period, both stations experienced negative air-sea temperature differences, low dew-point depression, and high relative humidity were maintained, with weak winds forming from the tidal flats to the shore.

Collection 5와 Collection 6 Aqua MODIS07_L2 기온과 이슬점온도 산출물간의 비교 및 지상 관측 자료와의 비교 (Comparisons of Collection 5 and 6 Aqua MODIS07_L2 air and Dew Temperature Products with Ground-Based Observation Dataset)

  • 장근창;강신규;홍석영
    • 대한원격탐사학회지
    • /
    • 제30권5호
    • /
    • pp.571-586
    • /
    • 2014
  • Moderate Resolution Imaging Spectroradiometer(MODIS)로부터 산출된 기온과 이슬점 온도프로파일 자료는 5 km의 공간해상도로 연속적으로 지상을 감시하고 있으며, 2012년부터 기존의 산출 알고리즘(Collection 5, C005)을 개선한 Collection 6(C006) MODIS07_L2 대기프로파일 자료를 생산하고 있다. 이 연구에서는 두 가지 버전의 알고리즘으로 산출된 Aqua MODIS07_L2(MYD07_L2) 대기 프로파일 자료로부터 획득한 기온과 이슬점 온도에 대한 신뢰도를 평가하는 것으로, 전국 77 개소 정규기상관측지점을 대상으로 하였다. 또한 기온과 이슬점 온도를 이용하여 대기수증기압을 추정하여 미기상인자 산출에 대한 MYD07_L2의 적용 가능성을 살펴보았다. C006 기온은 지상 관측 자료와 비교에서 C005 기온의 오차(ME = -1.89 K, RMSE = 4.06 K)보다 개선된 결과를 보였다(ME = -0.76 K, RMSE = 3.34 K). 한편, 이슬점 온도의 경우에는 C006이 C005의 오차(ME = -0.39 K, RMSE = 5.65 K)보다 크게 나타났다. MYD07_L2 산출 고도와 지상 관측지점 간에 발생할 수 있는 고도 차이를 보정하기 위해 대기기온감률 방법을 적용한 결과, 기온의 경우 C005와 C006에서 모두 개선 효과를 확인할 수 있었지만, 이슬점 온도의 경우에는 C006에서 오차가 소폭 증가하였다(1.4%). 두 가지 버전의 MYD07_L2 자료를 이용하여 대기수증기압을 추정한 결과, C006 자료를 이용하였을 때 다소 개선된 결과를 보였다. 이 연구를 통해 한국에 대한 C006 MYD07_L2 산출물 중 기온의 신뢰도가 전반적으로 개선되었음을 확인할 수 있었다.