• Title/Summary/Keyword: Device-to-Device (D2D) communication

Search Result 293, Processing Time 0.031 seconds

Interface trap density distribution in 3D sequential Integrated-Circuit and Its effect (3차원 순차적 집적회로에서 계면 포획 전하 밀도 분포와 그 영향)

  • Ahn, TaeJun;Lee, Si Hyun;Yu, YunSeop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2899-2904
    • /
    • 2015
  • This paper introduces about the effect on $I_{DS}-V_{GS}$ characteristic of transistor that interface trap charge is created by damage due to heat in a 3D sequential inverter. A interface trap charge distribution in oxide layer in a 3D sequential inverter is extracted using two-dimensional device simulator. The variation of threshold voltage of top transistor according to the gate voltage variation of bottom transistor is also described in terms of Inter Layer Dielectric (ILD) length of 3D sequential inverter, considering the extracted interface trap charge distribution. The extracted interface trap density distribution shows that the bottom $HfO_2$ layer and both the bottom and top $SiO_2$ layer were relatively more affected by heat than the top $HfO_2$ layer with latest process. The threshold voltage variations of the shorter length of ILD in 3D sequential inverter under 50nm is higher than those over 50nm. The $V_{th}$ variation considering the interface trap charge distribution changes less than that excluding it.

Hyper-reality Metaverse Technology Trends and Development Prospects (초실감메타버스 기술 동향 및 발전 전망)

  • Y.S. Cho;E.H. Hyun;S.J. Bae;H. Jeong;S.D. Ahn
    • Electronics and Telecommunications Trends
    • /
    • v.39 no.2
    • /
    • pp.1-11
    • /
    • 2024
  • The metaverse is expected to evolve into an immersive environment based on photorealistic stereoscopic imaging to integrate real and virtual worlds. To transition from flat images to immersive stereoscopic images, such as light fields and holograms, a continuous cycle of technological development should be reached in media, content, and device technologies, ranging from acquisition and generation to transmission and synthesis as well as reproduction and interaction. Additionally, owing to the multitude of components involved in the metaverse, proper service realization will be challenging without concurrent advancements in computing and communication technologies that facilitate the integration of such components. We introduce research and development trends in media, contents, and devices at the Electronics and Telecommunications Research Institute toward the next generation of stereoscopic images.

Design of a Plasmonic Switch Using Ultrathin Chalcogenide Phase-change Material

  • Lee, Seung-Yeol
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.239-246
    • /
    • 2017
  • A compact plasmonic switching scheme, based on the phase change of a thin-film chalcogenide material ($Ge_2Sb_2Te_5$), is proposed and numerically investigated at optical-communication wavelengths. Surface plasmon polariton modal analysis is conducted for various thicknesses of dielectric and phase-change material layers, and the optimized condition is induced by finding the region of interest that shows a high extinction ratio of surface plasmon polariton modes before and after the phase transition. Full electromagnetic simulations show that multiple reflections inside the active region may conditionally increase the overall efficiency of the on/off ratio at a specific length of the active region. However, it is shown that the optimized geometrical condition, which shows generally large on/off ratio for any length of active region, can be distinguished by observing the multiple-reflection characteristic inside the active region. The proposed scheme shows an on/off switching ratio greater than 30 dB for a length of a few micrometers, which can be potentially applied to integrated active plasmonic systems.

In-vehicle Dilemma Zone Warning System at Signalized Intersections (신호교차로 내 딜레마구간 차내경고시스뎀 개발)

  • Moon Young-Jun;Lee Joo-Il
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.2 no.1 s.2
    • /
    • pp.53-62
    • /
    • 2003
  • This paper demonstrates the in-vehicle dilemma zone warning system (DZWS) project developed as a part of the Driver Advisory and Collision Warning System in Automated Vehicle and Highway System (AVHS). The DZWS project, one of the Korea national ITS projects in 2000 develops the in-vehicle warning device to support drivers' decision making on whether to stop or to proceed to clear the intersection prior to the onset of yellow signal for avoiding the high risk of collision at signalized intersections through the dedicated short range communication (DSRC). This paper explores the design of optimal communication systems between roadway and vehicles, the operational and functional concepts of dilemma zone warning system based on appropriate approach speeds, and the system integration for field test at two sites of signalized intersections. Findings from the system integration indicated that the system would be implemented in eliminating the dilemma zone relative to approach speeds and in reducing red light violations and intersection collisions through the in-vehicle warning device at signalized intersection.

  • PDF

An MMIC VCO Design and Fabrication for PCS Applications

  • Kim, Young-Gi;Park, Jin-Ho
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.202-207
    • /
    • 1997
  • Design and fabrication issues for an L-band GaAs Monolithic Microwave Integrated Circuit(MMIC) Voltage Controlled Oscillator(VCO) as a component of Personal Communications Systems(PCS) Radio Frequency(RF) transceiver are discussed. An ion-implanted GaAs MESFET tailored toward low current and low noise with 0.5mm gate length and 300mm gate width has been used as an active device, while an FET with the drain shorted to the source has been used as the voltage variable capacitor. The principal design was based on a self-biased FET with capacitive feedback. A tuning range of 140MHz and 58MHz has been obtained by 3V change for a 600mm and a 300mm devices, respectively. The oscillator output power was 6.5dBm wth 14mA DC current supply at 3.6V. The phase noise without any buffer or PLL was 93dB/1Hz at 100KHz offset. Harmonic balance analysis was used for the non-linear simulation after a linear simulation. All layout induced parasitics were incorporated into the simulation with EEFET2 non-linear FET model. The fabricated circuits were measured using a coplanar-type probe for bare chips and test jigs with ceramic packages.

  • PDF

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources (감마선원의 공간분포 가시화 및 3D모델링을 위한 운용환경 개발)

  • Song, Keun-Young;Lim, Ji-Seok;Choi, Jung-Huk;Yuk, Young-Ho;Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.702-704
    • /
    • 2017
  • In case of dismantling of nuclear power generation facility or radiation accident, the accurate information of gammaray source is essential for rapid decontamination. In order to more efficiently represent the position of the gamma ray to be removed, we create a spatial domain based on the real image. And we can perform decontamination of gamma-ray source more quickly by expressing the distribution of radiation source. The developed gamma ray imaging device overlaps with the visible image after gamma - ray detection and provides only two - dimensional image, but it does not show the distance information to the source. In this paper, we have developed a operation environment using the 3D visualization model for reporting effective decontamination operation.

  • PDF

Design of Radiation Pattern Reconfigurable Antenna for Vital Signal Sensing Device Attached on Wristband and SAR Analysis on Human body (팔목 부착형 생체신호 측정기기에 사용가능한 방사패턴 재구성 안테나 설계 및 인체 SAR 영향 분석)

  • Lee, Chang Min;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.666-670
    • /
    • 2015
  • This paper presents radiation pattern reconfigurable antenna for Fitbit Flex wristband which detects vital signal. Also, the paper presents Specific Absorption Rate (SAR) from the loop-dipole radiation pattern reconfigurable antenna based on the position of human body. The proposed loop-dipole radiation pattern reconfigurable antenna produces two opposite side direction radiation pattern using two RF switches. The resonant frequency of the radiation pattern reconfigurable antenna is Bluetooth communication bandwidth (2.4 - 2.485 GHz) and the maximum gain of the proposed antenna is 1.96 dBi. The proposed antenna satisfied the standard SAR value of 1.6 W/kg in 1 g tissue of the human body when the Bluetooth communication input average power of 0.04 W is excited to five parts of human body (head, chest, stomach, back, wrist). The maximum SAR value of in this simulation is presented in the part of head.

Development of Electronic Circuit for Korotkoff Sounds Detecting Signal on Forearm Electronic Blood Pressure Monitor (팔뚝 전자혈압계의 코로트코프 음 신호 검출을 위한 전자 회로 개발)

  • Lee, Sangsik;Cho, Yoehan;Goo, Jihyun;Lee, Choongho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • In this study, we developed a circuit device detecting korotkoff sounds of forearm electronic blood pressure monitor by digital signal. In order to test a circuit detecting signal from korotkoff sounds, systolic and diastolic pressure were compared our developed circuit device with the existing forearm electronic blood pressure monitor (Model: SE-7000, Korea). Devices for an experiment composed of a forearm cuff, a stethoscope, an amplifier, a PC with A/D board, etc. Results of korotkoff sounds was similar to a pattern of oscilometric signals from the existing forearm electronic blood pressure monitor. We thought it is possible to measure blood pressures, if blood pressures were detected precisely using signals of korotkoff sounds.

  • PDF

Closed-Loop Transmit Diversity Techniques for Small Wireless Terminals and Their Performance Assessment in a Flat Fading Channel

  • Mostafa, Raqibul;Pallat, Ramesh C.;Ringel, Uwe;Tikku, Ashok A.;Reed, Jeffrey H.
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.319-329
    • /
    • 2012
  • Closed-loop transmit diversity is considered an important technique for improving the link budget in the third generation and future wireless communication standards. This paper proposes several transmit diversity algorithms suitable for small wireless terminals and presents performance assessment in terms of average signal-to-noise ratio (SNR) and outage improvement, convergence, and complexity of operations. The algorithms presented herein are verified using data from measured indoor channels with variable antenna spacing and the results explained using measured radiation patterns for a two-element array. It is shown that for a two-element array, the best among the proposed techniques provides SNR improvement of about 3 dB in a tightly spaced array (inter-element spacing of 0.1 wavelength at 2 GHz) typical of small wireless devices. Additionally, these techniques are shown to perform significantly better than a single antenna device in an indoor channel considering realistic values of latency and propagation errors.