• 제목/요약/키워드: Device-to-Device

검색결과 25,316건 처리시간 0.053초

기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가 (Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter)

  • 이채린;이현화;임재한;송승영
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

An Exploration of Various Evaluation Methods to Improve Usability of Museum Mobile Device

  • Ahn, Mi-Lee;Cha, Hyun-Jin;Hwang, Yun-Ja;Kim, Hee-Jin
    • 대한인간공학회지
    • /
    • 제30권6호
    • /
    • pp.765-773
    • /
    • 2011
  • Objective: This study aims towards exploring a model of the HCI evaluation methods to improve the usability of mobile device, based on a case of a Mobile PDA system in a Museum context. Background: Mobile PDA systems in a Museum context is widely utilized for the educational purposes, but it is criticized for low usability that the device only play a role in textbooks on legs without any interactive educational activities. Therefore, the usability improvements on the mobile PDA system should be considered. Method 1: This model was developed with a combination of the expert review and the user testing, and with a combination of the qualitative and quantitative studies. In more details, first of all, a qualitative study was conducted as a combination of three different methods: 1) expert review with heuristics, 2) interviews with persons working in a museum, and 3) contextual enquiry. Results 1: The experts review provided with critical usability issues, and the semi-constructive interview helped to understand the background of the mobile device. Lastly, the contextual enquiry showed user experience problems and directions of improving the device from user's perspective. Method 2: Based on the results of the qualitative study, a questionnaire was designed. Results 2: The analysis of the quantitative study was conducted to generalize the problems, and prioritize the direction of improving the device within the limitation of the cost and time in a museum. Conclusion: This study has implications in developing an example of a HCI evaluation model to improve the user experience of the mobile device as well as finding problems and directions of how to improve the mobile PDA systems in the museum. Application: In fact, most of the studies related to the evaluation of the mobile device have been conducted in a laboratory context due to the cost and time. This paper, however, attempted to apply to various HCI research techniques from different constituents in real context.

DACUM 법을 활용한 유비쿼터스 의료전자기기 전문가의 직무분석 (Job Analysis of Ubiquitous Medical Electronic Device Export by the Method of DACUM)

  • 조동헌;구경완
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1192-1197
    • /
    • 2013
  • In this paper Ubiquitous Medical Electronic Device Export was defined, and it's job analysis. The authors have been defined the job and classified duties and tasks of Ubiquitous Medical Electronic Device Export. To fine what is the most efficient task for Ubiquitous Medical Electronic Device Export, we have been investigated the levels of importance, difficulty, frequency and entry in each task. A DACUM committee is composed of total 12 members, which are one facilitator, 10 panel members, one coordinator & recorder to analyze the job of Ubiquitous Medical Electronic Device Export. Following is the result of this study. First, The process began with the identification of a job title and definition of Ubiquitous Medical Electronic Device Export. Second, a job model of Ubiquitous Medical Electronic Device Export is constructed based on the results of DACUM job analysis. 5 duties and 33 tasks are analyzed. Third, occupational specification was drawn up in consultation with SME council. Fourth, duty specification was drawn up in consultation. 33 tasks that are essential in entry level of occupation are identified. Fifth, task specification was drawn up in consultation. Detail task component which include skill, materials, knowledge, equipment, achievement level and tool was specified in task specification.

Plasma polymer passivated organic light emitting diodes

  • Cho, Dae-Yong;Kim, Min-Su;Jung, Dong-Geun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.893-896
    • /
    • 2003
  • Plasma polymerized para-xylene (PPpX) thin films deposited by plasma enhanced chemical vapor deposition (PECVD) were used to passivate the organic light emitting diodes (OLEDs). For OLEDs, indium tin oxide (ITO), N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-diphenyl-4,4'-diamine (TPD), tris(8-hydroxyquinoline) aluminum $(Alq_{3})$ and aluminum (Al) were used as the anode, the hole transport layer (HTL), the emitting layer (EML) and the cathode, respectively. The OLED device with the PPpX passivation film (passivated device) showed similar electrical and optical characteristics to those of the OLED device without the PPpX passivation film (control device), indicating that the PECVD process did not degrade the performance of the OLEDs notably. The lifetime of the passivated device was two times longer than that of the control device. Passivation of OLEDs with PPpX films also suppressed the growth of dark spots. The density and size of dark spots of the passivated device were much smaller than those of the control device.

  • PDF

Partially-insulated MOSFET (PiFET) and Its Application to DRAM Cell Transistor

  • Oh, Chang-Woo;Kim, Sung-Hwan;Yeo, Kyoung-Hwan;Kim, Sung-Min;Kim, Min-Sang;Choe, Jeong-Dong;Kim, Dong-Won;Park, Dong-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권1호
    • /
    • pp.30-37
    • /
    • 2006
  • In this article, we evaluated the structural merits and the validity of a partially insulated MOSFET (PiFET) through the fabrication of prototype transistors and an 80 nm 512M DDR DRAM with partially-insulated cell array transistors (PiCATs). The PiFETs showed the outstanding short channel effect immunity and off-current characteristics over the conventional MOSFET, resulting from self-induced halo region, self-limiting SID shallow junction, and reduced junction area due to PiOX layer formation. The DRAM with PiCATs also showed excellent data retention time. Thus, the PiFET can be a promising alternative for ultimate scaling of planar MOSFET.

u-라이프케어 모니터링 시스템 단말기 개발 (Development of u-Lifecare Monitoring System Device)

  • 최동운;강윤정
    • 한국정보통신학회논문지
    • /
    • 제16권7호
    • /
    • pp.1533-1540
    • /
    • 2012
  • u-라이프 케어 단말기는 생체 정보를 수집하고, 운동을 패턴 별로 분류, 저장하고 일정 시간마다 안드로이드 폰에 블루투스 무선통신을 통해 전송한다. 전송된 정보는 안드로이드 폰 어플리케이션을 통해 확인할 수 있다. u-라이프 케어 단말기는 3축 가속도 센서를 이용하여 활동량을 모니터링한 후 소모한 칼로리를 계산한다. 생체 데이터 마이닝을 통해 건강상태를 판단하고 적절한 맞춤형 운동치료를 컨설팅하게 된다. 생체 정보를 전송할 때 블루투스 무선통신을 통해 안드로이드 폰에 바로 전송하기 때문에 기존의 라이프케어 제품들에서 센싱된 정보를 웹서버에 전송하기 위해 사용되어지는 모바일 게이트웨이나 홈 게이트웨이가 별도로 필요치 않다는 장점을 가지고 있다.

유무선 인터넷 환경에서의 장비관리시스템 개발 (Development of Device Management System in Wire and Wireless Internet Environments)

  • 박상국;문상호;김문환
    • 한국정보통신학회논문지
    • /
    • 제7권7호
    • /
    • pp.1483-1490
    • /
    • 2003
  • 기존의 산업현장에서는 장비관리자가 장비의 모니터링과 제어를 위하여 항상 대기하고 있어야 한다. 이로 인하여 인력 낭비와 시간 손실이 많으므로 비효율적이다. 본 논문에서는 이러한 문제점을 해결하기 위하여 유무선 인터넷을 기반으로 하는 실시간 장비관리시스템을 개발한다. 이 시스템에서는 장비에 이상 발생 시 고장을 자동으로 감지하여 장비관리자의 휴대폰으로 통보하고, 관리자가 유무선 인터넷을 통하여 고장장비에 대한 응급조치를 한다. 이를 위하여 세부적으로 로컬 장비제어시스템, 장비관리시스템, 모바일 시스템, 웹 시스템을 각각 개발한다.

Development of Complex Energy Saving Device

  • Lee, Kwi-Joo;An, Jung-Sun
    • 한국해양공학회지
    • /
    • 제26권3호
    • /
    • pp.1-5
    • /
    • 2012
  • A complex energy saving device has been developed for middle class vessels. The propulsive performance of the developed device is described through a model test. The pre-swirl stator, which recovers the rotational energy of the propeller slipstream, is a well-known energy saving device for large vessels. The pre-swirl stator for a large vessel is usually cast as a part of the stern frame and has a high cost. The manufacture of a cast stator for an existing vessel is almost impossible. The complex device that was developed can be fitted on astern frame by welding. The model tests show a 4-6% efficiency gain for middle class vessels with the developed appendages compared to those with bare hulls.

Complete Parameter Identification of Gough-Stewart platform with partial pose measurements using a new measurement device

  • Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.825-830
    • /
    • 2004
  • Kinematic calibration of Gough-Stewart platform using a new measurement device is presented in this paper. The device simultaneously measures components of position and orientation using commercially available gadgets. Additional kinematic parameters are defined to model the sources of inaccuracies for the proposed measurement device. Computer simulations reveal that all kinematic parameters of the Gough-Stewart platform and the additional kinematic parameters of the measurement device can be identified with the partial pose measurements of the device. Results also show that identification is robust for the initial errors and the noise in measurements. The device also facilitates the automation of easurement procedure.

  • PDF

Analysis on Self-Heating Effect in 7 nm Node Bulk FinFET Device

  • Yoo, Sung-Won;Kim, Hyunsuk;Kang, Myounggon;Shin, Hyungcheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권2호
    • /
    • pp.204-209
    • /
    • 2016
  • The analyses on self-heating effect in 7 nm node non-rectangular Bulk FinFET device were performed using 3D device simulation with consideration to contact via and pad. From self-heating effect simulation, the position where the maximum lattice temperature occurs in Bulk FinFET device was investigated. Through the comparison of thermal resistance at each node, main heat transfer path in Bulk FinFET device can be determined. Self-heating effect with device parameter and operation temperature was also analyzed and compared. In addition, the impact of interconnects which are connected between the device on self-heating effect was investigated.