• Title/Summary/Keyword: Device-to-Device

Search Result 25,364, Processing Time 0.044 seconds

A Review of RRAM-based Synaptic Device to Improve Neuromorphic Systems (뉴로모픽 시스템 향상을 위한 RRAM 기반 시냅스 소자 리뷰)

  • Park, Geon Woo;Kim, Jae Gyu;Choi, Geon Woo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.50-56
    • /
    • 2022
  • In order to process a vast amount of data, there is demand for a new system with higher processing speed and lower energy consumption. To prevent 'memory wall' in von Neumann architecture, RRAM, which is a neuromorphic device, has been researched. In this paper, we summarize the features of RRAM and propose the device structure for characteristic improvement. RRAM operates as a synapse device using a change of resistance. In general, the resistance characteristics of RRAM are nonlinear and random. As synapse device, linearity and uniformity improvement of RRAM is important to improve learning recognition rate because high linearity and uniformity characteristics can achieve high recognition rate. There are many method, such as TEL, barrier layer, NC, high oxidation properties, to improve linearity and uniformity. We proposed a new device structure of TiN/Al doped TaOx/AlOx/Pt that will achieve high recognition rate. Also, with simulation, we prove that the improved properties show a high learning recognition rate.

Fabrication of a Breathing Assist Device for Saxophone Players with Breathing Problems

  • Kato, Tomonori;Ashikari, Tadataka;Matoba, Chikara;Mawatari, Asashi;Thumwarin, Pitak
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.72-76
    • /
    • 2021
  • The aim of this study was to establish a breathing assist system for saxophone players with breathing problems. Although the saxophone is a popular wind instrument with a reed in its mouthpiece, it can be difficult for people with breathing problems to play this instrument, as it requires adequate breath support for deep and even long breaths. To solve this problem, the authors propose a breathing assist device, which functions like a pneumatic master-slave amplifier, for saxophone players with breathing problems. First, the proposed device is fabricated. Second, the effectiveness of the breathing assist device as a master-slave amplifier is confirmed through experiments. Third, the dynamic characteristics of the device are tested up to 10 Hz, and they demonstrate that the device responds well for up to approximately 5 Hz.

The Effect of the User Attitude towards Digital Device of the Middle and Older Adults on Life Satisfaction: Mediating Effect of the Utilization Performance of Digital Device (장노년층의 디지털기기 이용태도가 삶의 만족도에 미치는 영향 : 디지털기기 이용성과의 매개효과)

  • Kim, Su Kyoung;Shin, Hye Ri;Kim, Young Sun
    • The Journal of Information Systems
    • /
    • v.30 no.1
    • /
    • pp.85-104
    • /
    • 2021
  • Purpose This study aims to verify the mediating effect of the utilization performance of digital device on the relationship between user attitude and life satisfaction. Design/methodology/approach Using the data of 2018 Digital Divide Survey conducted by the National Information Society Agency(NIA), the mediating effect was verified by Baron & Kenny (1986)'s 3 step process, targeting 1,662 adults older than 55. Findings The result is as follows: first, the user attitude of middle and older aged people has a positive effect on their life satisfaction. Second, the effect of user Attitude towards Digital Device of middle and older citizens is partially mediated by the utilization performance of digital device. The results of this study indicate that when providing informatization education in the local community to promote the use of digital devices for the elderly, efforts should be made to grasp the level and inclination of informatization individually, and furthermore present improvements for wireless devices that the elderly can easily access in their daily lives. This study is expected to be a groundwork for a practical intervention to boost positive attitude towards using digital device to enhance the utilization performance of digital device and the life satisfaction of middle and older aged people.

Process-Structure-Property Relationship and its Impact on Microelectronics Device Reliability and Failure Mechanism

  • Tung, Chih-Hang
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.3
    • /
    • pp.107-113
    • /
    • 2003
  • Microelectronics device performance and its reliability are directly related to and controlled by its constituent materials and their microstructure. Specific processes used to form and shape the materials microstructure need to be controlled in order to achieve the ultimate device performance. Examples of front-end and back-end ULSI processes, packaging process, and novel optical storage materials are given to illustrate such process-structure-property-reliability relationship. As more novel materials are introduced to meet the new requirements for device shrinkage, such under-standing is indispensable for future generation process development and reliability assessment.

A Study of Applied Pressure According to Knee variable During Lachman Test for Anterior Cruciate Ligament using Telos Device (Telos Device를 이용한 전방십자인대 Lachman 검사 시 무릎두께와 활성도에 따른 인가압력에 대한 고찰)

  • Lim, Jong-Cheon;Kim, Sang-Hyuk;Seo, Sang-Hyuk;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.391-398
    • /
    • 2019
  • The purpose of study is to investigate the difference of the daN force applied during the examination using Telos Device and the degree of fluctuation of anterior cruciate ligament according to the individual differences of the muscles involved in knee stability. The examination was done by the Lachman test using Telos Device and the changes of anterior cruciate ligament were measured by varying the force of 0. 15, 30 daN on each right and left side and the force of 30 daN after the bruce protocol. Computed tomography (CT) was used to measure muscle mass. As a result of measuring the degree of fluctuation of the anterior cruciate ligament according to the change of the force applied to the Telos Device, there was a statistically significant difference in the knee fluctuation when 15 daN and 30 daN were applied on both right and left. Also, it is analyzed that the degree of fluctuation of anterior cruciate ligament varies according to the difference of individual's muscle mass. Therefore, it is considered that the force applied to the Telos Device should be changed according to the difference of individual's muscle mass.

Design and Implementation of Wireless standby Power Control System for Energy Saving (에너지 절감을 위한 무선 대기전력 제어 시스템 설계 및 구현)

  • Sim, Gab-Sig;Jang, Jae-Hyuk
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.5
    • /
    • pp.19-27
    • /
    • 2013
  • This paper implements the standby power control system composed of a master device and slave devices. The standby power is managed by cutting power supply after controlling the relay of a slave device based on the authentication of master device's RFID card. RFID interface and wireless communication module are embedded in a master device, and one master device is linked with many slave devices in wireless. Each slave device executes the operation needed in power control independently. We implements the function of manual power on/off system in a slave device, and the function of user ID enrollment by switch manipulation in a master device. Also this system can communicate bidirectionally in wireless and runs on TinyOS. The result of experiment shows that the user authentication is executed in a master device and this authenticated information is transmitted to a slave device in wireless, and standby power is cutted by controlling the relay of a slave device. Installing this system in a building or an office, we can expect energy saving.

Development of a Vertebral Fusion Device and Its Mechanical Analysis using 3-D Finite Element Method (척추용 퓨전 디바이스의 개발 및 3차원 유한요소법을 이용한 역학적 해석)

  • 김현수;전병찬;손한철;최경호;박정호;최태원
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.385-390
    • /
    • 2002
  • Nowadays, there are many attempts to develop domestic medical-equipments. In this study, it is performed to developed a new vertebral fusion device. The basic models are a rectangular-frame type and a screw type which are generally used for the patients. The main purpose of the development of a new device is to reduce the amount of bone taken out for the insertion of a device to vertebral disc and this paper is focused on th concept of a new device shape. In the results, two types are devised. One is a folding type and the other is a separate-push-in type device both are in primitive stage. However, in a folding type there are mechanical pins and the analysis of pins and the lock system is still in study and needs some time. Therefore a separate-push-in type is introduced in this study mainly and a prototype and 3-D finite element model are made and experimented and stress analyzed. From the results it is considered that it is stable for the basic loading condition of vertebra, however, it is required to develop a supporting operational equipment for the convenience of the operation in practice.

Device Information Processing System for Securing Interoperability of Mobile Web Service (모바일 웹 서비스의 상호운용성 확보를 위한 단말정보 처리 시스템)

  • Kim, Chang-Su;Choi, Bong-Kyu;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1185-1192
    • /
    • 2010
  • Recently, the demand for various contents and mobile web service has been rising due to the improvement of the techniques of wireless networks. In mobile web service, it is essential to exchange the device informations and contents using specific information which are standardized for users, operators and contents providers. This is based on the existing service providers based on the existing terminal, which provides information to help plan and operate independently of the mobile Web services and content services for various users needs. In this paper, the interoperable DDL is proposed for providing contents to fit with each different mobile device, which contributes toward the optimized mobile web service and guarantee the interoperability of device information. and we implemented the device information processing system, which has the purpose of servicing the device information and verifying the result to the interoperability of mobile web service on proposed DDL and the description language of the device information.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

A Study on Development of Non-Powered Horse Riding Device for Enhancement of Core Muscle (코어근육군 강화를 위한 무동력 승마운동기구개발에 관한 연구)

  • Lim, Young-Tae;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.353-361
    • /
    • 2015
  • Objective : The aim of this study was to develop the non-powered horse riding device and was to evaluate the elaborate its applicability throughout static structural and transient structural analysis of the outdoor core strength exercise equipment. Method : Fifteen college students (mass: $69.55{\pm}13.38kg$, height: $1.69{\pm}5.61m$, age: $21.42{\pm}1.83yrs$) rode the powered horse riding device and 14 college students (mass: $71.12{\pm}9.74kg$, height: $1.73{\pm}3.31m$, age: $22.50{\pm}1.47yrs$) rode the non-powered horse riding device for the comparison. All motion capture data was collected at 100 Hz using six infrared cameras and the muscular activities were collected using a Delsys Trigno wireless system. The peak forward/backward lean angle, range of motion anter/posterior and vertical COM(Center of mass) movement of trunk and pelvis segment, and muscle activities of six muscles were compared between the two devices by using independent t-test (p<.05). Results : Several kinematic variables (peak forward-backward lean angle and vertical COM movement of trunk and pelvis segment, range of motion of trunk) significantly different between non-powered and powered horse riding device. The muscle activities of Rectus abdominis and External oblique of abdomen on the non-powered horse riding device were significantly greater than those of the powered device. Conclusion : It was concluded that non-power horse riding device could give the effect of core strength exercise as well as the body motion which can simulate the powered horse riding device.