• 제목/요약/키워드: Device Wafer

검색결과 362건 처리시간 0.024초

웨이퍼 스텝퍼의 정렬정확도 측정에 관한 연구 (Measurement methodology for the alignment accuracy of wafer stepper)

  • 이종현;장원익;이용일;김도훈;최부연;남병호;김상철;권진혁
    • 한국정밀공학회지
    • /
    • 제11권1호
    • /
    • pp.150-156
    • /
    • 1994
  • To meet the process requirement of semiconductor device manufacturing, it is necessary to improve the alignment accuracy in exposure equipments. We developed the excimer laser stepper and will describe the methodology for alignment measurement and experimental results. Our wafer alignment system consists of off-axis optics, TTL(Through The Lens) optics and high precision stage. Off-axis alignment utilizes the image processing and /or diffraction from thealign marks of off-centered chip area. On the other hand, TTL alignment can be used for the die-by-die alignment using dual beam interferometry. When only off-axis alignment was used, the experimental alignment error(lml+3 .sigma. ) was 0.26-0.29 .mu. m, and will be reduced down to 0.15 .mu. m by adding TTL alignment.

  • PDF

디바이스 내장형 플렉시블 전자 모듈 제조 및 신뢰성 평가 (Fabrication and Reliability Test of Device Embedded Flexible Module)

  • 김대곤;홍성택;김덕흥;홍원식;이창우
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.84-88
    • /
    • 2013
  • These days embedded technology may be the most significant development in the electronics industry. The study focused on the development of active device embedding using flexible printed circuit in view of process and materials. The authors fabricated 30um thickness Si chip without any crack, chipping defects with a dicing before grinding process. In order to embed chips into flexible PCB, the chip pads on a chip are connected to bonding pad on flexible PCB using an ACF film. After packaging, all sample were tested by the O/S test and carried out the reliability test. All samples passed environmental reliability test. In the future, this technology will be applied to the wearable electronics and flexible display in the variety of electronics product.

마이크로컬럼 어레이에 적용 가능한 웨이퍼단위의 수직 배선 방법 (Wafer level vertical interconnection method for microcolumn array)

  • 한창호;김현철;강문구;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.793-796
    • /
    • 2005
  • In this paper, we propose a method which can improve uniformity of a miniaturized electron beam array for inspection of very small pattern with high speed using vertical interconnection. This method enables the individual control of columns so that it can reduce the deviation of beam current, beam size, scan range and so on. The test device that used vertical interconnection method was fabricated by multiple wafer bonding and metal reflow. Two silicon and one glass wafers were bonded and metal interconnection by melting of electroplated AuSn was performed. The contact resistance was under $10{\Omega}$.

  • PDF

케미컬오일을 이용한 ERF 연마 특성 (Characteristics of ERF Polishing using Chemical-oil)

  • 윤종호;이재종;이응숙;이동주;김영호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.27-33
    • /
    • 2004
  • Electro-theological fluid is recently used for the micro polishing of 3-dimensional micro-aspherical lens. It's also used for polishing small area defects on the wide flat wafer. Since ER fluid shows a behavior of viscosity changing under certain electric fields. micro polishing efficiency may be enhanced for certain cases. In this paper, a perfluorinated carbonyl fluoride oil based ER fluids was used to improve surface polishing rate and submicron-scale accuracy. As the polishing electrodes, micro size cylindrical tools had been used for maximizing the electric field. An experimental device, which was applied for micro polishing a number of wafers of 4inches in size and other workpiece. was made on a precision polishing system. It consisted of a steel electrode. a wafer fixture. l0㎃ current and DC 5㎸ power supply unit, and a controller unit. From the Experiments. the ER fluid is applicable for micro polishing of small parts.

  • PDF

회전형 CMP장비의 속도 및 마찰력 분포 해석 (Velocity and Friction Force Distribution in Rotary CMP Equipment)

  • 김형재;정해도;이응숙;신영재
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.39-39
    • /
    • 2003
  • As the design rules in semiconductor manufacturing process become more and more stringent, the higher degree of planarization of device surface is required for a following lithography process. Also, it is great challenge for chemical mechanical polishing to achieve global planarization of 12” wafer or beyond. To meet such requirements, it is essential to understand the CMP equipment and process itself. In this paper, authors suggest the velocity distribution on the wafer, direction of friction force and the uniformity of velocity distribution of conventional rotary CMP equipment in an analytical method for an intuitive understanding of variation of kinematic variables. To this end, a novel dimensionless variable defined as “kinematic number” is derived. Also, it is shown that the kinematic number could consistently express the velocity distribution and other kinematic characteristics of rotary CMP equipment.

회전형 CMP장비의 속도 및 마찰력 분포 해석 (Velocity and Friction Force Distribution in Rotary CMP Equipment)

  • 김형재;정해도;이응숙;신영재
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.29-38
    • /
    • 2003
  • As the design rules in semiconductor manufacturing process become more and more stringent, the higher degree of planarization of device surface is required for a following lithography process. Also, it is great challenge for chemical mechanical polishing to achieve global planarization of 12” wafer or beyond. To meet such requirements, it is essential to understand the CMP equipment and process itself. In this paper, authors suggest the velocity distribution on the wafer, direction of friction force and the uniformity of velocity distribution of conventional rotary CMP equipment in an analytical method for an intuitive understanding of variation of kinematic variables. To this end, a novel dimensionless variable defined as “kinematic number” is derived. Also, it is shown that the kinematic number could consistently express the velocity distribution and other kinematic characteristics of rotary CMP equipment.

PC 기반의 다이싱 공정 자동화 시스템 개발

  • 김형태;양해정;송창섭
    • 한국정밀공학회지
    • /
    • 제17권3호
    • /
    • pp.47-57
    • /
    • 2000
  • In this study, PC-based dicing machine and driving software were constructed for the purpose of automation of wafer cutting process. To automate the machine, hard automation including vision, loading, and software were considered in the development. Auto loading device and vision system were adopted for the increase of productivity, GUI software programmed for the expedient operation. The dicing machine is operated by the control algorithm and some parameters. It is verified that this kind of PC based automation has a great potential compared with the conventional dicing machine when applied to manufacturing some kinds of wafers as a test purpose.

  • PDF

Improved Rs Monitoring for Robust Process Control of High Energy Well Implants

  • Kim, J.H.;Kim, S.;Ra, G.J.;Reece, R.N.;Bae, S.Y.
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2007년도 춘계학술대회
    • /
    • pp.109-112
    • /
    • 2007
  • In this paper we describe a robust method of improving precision in monitoring high energy ion implantation processes. Ion implant energy accuracy was measured in the device manufacturing process using an unpatterned implanted layer on an intrinsic p-type silicon wafer. To increase Rs sensitivity to energy at the well implant process, a PN junction structure was formed by P-well and deep N-well implants into the p-type Si wafer. It was observed that the depletion layer formed by the PN junction was very sensitive to energy variation of the well implant. Conclusively, it can be recommended to monitor well implant processes using the Rs measurement method described herein, i.e., a PN junction diode structure since it shows excellent Rs sensitivity to variation caused by energy difference at the well implant step.

  • PDF

초고밀도집적반도체 장비의 송풍형 정전기 제거 장치 개발 (Development of The System of Clearing Static Electricity with A Fan in the VLSI Device)

  • 이종호;전성호
    • 전자공학회논문지 IE
    • /
    • 제46권3호
    • /
    • pp.26-32
    • /
    • 2009
  • 반도체 산업에서, 웨이퍼가 오염되는 불량률 원인의 70%는 웨이퍼 자체의 대전이다. 본 논문은 기존의 고전압을 이용한 코로나 방전식의 송풍형 정전기 제거장치를 개발하였다. 이 시스템은 방전 침 세정 기능을 자동으로 구현하여 균형하게 이온을 방출하도록 하였고, 이온 방출 상태를 감지하여 최적의 이온량을 조절하도록 하였으며, Zigbee 통신모듈을 이용하여 전 시스템을 모니터링하도록 하였다.

나노 임프린트 리소그라피에 의한 마스터 복제 공정 (Fabrication of Master Replication by Nanoimprint Lithography)

  • 정명영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1078-1082
    • /
    • 2003
  • A feasibility study for the fabrication of master replication with nanostructures by Nanoimprint Lithography (NIL) was investigated for application of polymer Photonic Bandgap (PBG) devices used in photonic IC. Large area gratings of $9{\times}15(mm^2)$ with p = 400 nm was successfully embossed on PMMA on silicon wafer and the embossing parameters (temperature, pressure, time) were established. A precise control of $O_2$ plasma Reactive Ion Etching (RIE) process time allowed window opening over the whole area despite the presence of wafer bending. Master replication with aspect ratio 1 was successfully fabricated, but master replication with aspect ratio 3 needs to optimize parameters. All replications were done in a NIL process.

  • PDF