• Title/Summary/Keyword: Device

Search Result 29,634, Processing Time 0.074 seconds

Development and Evaluation of Smart Jacket with Embedded Wearable Device (웨어러블 디바이스를 이용한 기능성 스마트 재킷 개발 및 평가)

  • Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.3
    • /
    • pp.395-407
    • /
    • 2008
  • As global interest in clothing spreads over the smart clothing which arouses high added-value in the apparel industry, this study is to develop a smart jacket with an electrically-vibrating device maintaining excellent appearance and comfort. The vibrating device has a massage function that could relieve muscle pain near shoulders and neck. The purposes of this research are to develop jacket pattern for men in their thirties considering body shapes and fashion trend, to develop a wearable device that is composed of motor and controller and integrate it into a jacket, and to assess the external appearance and functional satisfaction of the smart jacket through the wearing test. The results are as follows: 1. In order to develope an appropriate jacket pattern for men in their thirties, several patterns were assessed for their fitting comfort. The final pattern was completed after making alterations some parts, and showed high satisfaction as 3.6(on a five-point scale) in all categories. 2. A vibrating device was developed by connecting motor, controller, battery and switch. Developing this device, focus was maximizing the strength of motor and minimizing the heat generated from motor and controller. Snaps were placed between inner and outer cloth of jacket so that the vibrating device could be easily attachable and detachable. The motor was located around Trapezius where muscles often get stiff. A switch was designed to be used in selecting the modes of Strong, Weak, and Cross Tapping. 3. The wearing test was conducted to examine outer appearance, comfort for motion, and functionality of the smart jacket. The results of assessing outer appearance showed that the location for attaching the vibrating device was not noticeable but looked natural, and there is almost no change in outer appearance when the vibrating device operates. The result of assessing comfort of action revealed that wearer's satisfaction was high in all categories about activity, wearer's comfort, etc. The result also showed that wear's satisfaction for effects of vibrating massage, easiness in using the device, heat generation was not less than 3.5 in all categories except a category about noise.

Highly Manufacturable 65nm McFET (Multi-channel Field Effect Transistor) SRAM Cell with Extremely High Performance

  • Kim, Sung-Min;Yoon, Eun-Jung;Kim, Min-Sang;Li, Ming;Oh, Chang-Woo;Lee, Sung-Young;Yeo, Kyoung-Hwan;Kim, Sung-Hwan;Choe, Dong-Uk;Suk, Sung-Dae;Kim, Dong-Won;Park, Dong-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2006
  • We demonstrate highly manufacturable Multi-channel Field Effect Transistor (McFET) on bulk Si wafer. McFET shows excellent transistor characteristics, such as $5{\sim}6 times higher drive current than planar MOSFET, ideal subthreshold swing, low drain induced barrier lowering (DIBL) without pocket implantation and negligible body bias dependency, maintaining the same source/drain resistance as that of a planar transistor due to the unique feature of McFET. And suitable threshold voltage ($V_T$) for SRAM operation and high static noise margin (SNM) are achieved by using TiN metal gate electrode.

The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform using Cortex-A8 (Cortex-A8을 이용한 Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현)

  • Joh, Yool-hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.312-315
    • /
    • 2012
  • Generally, SAW device, which uses Time Domain Sampling, requires high speed AD converter because SAW device (TDS) needs high sampling speed as much as its high data speed. However, the high price of AD converter discourages makers from using it. On the other hand, SAW device, which uses Frequency Domain Sampling, does not required high speed AD converter because SAW device (FDS) does not need high sampling speed. It is very efficient in price comparison to its performance because high processing speed of SAW device (FDS) can be implemented using low price Embedded Systems. The purpose of the thesis is to solve the issues above by designing and realizing SAW device (FDS) using SAW sensor for TDS.

  • PDF

Effects of Parent-Child Attachment, Parental Involvement in Child-Rearing and Instruction for Children's Effective Use of Smart Devices on Young Children's Smart-Device Overuse Behavior (부모의 자녀애착, 양육 참여 및 스마트기기 사용지도가 유아의 스마트기기 과다 사용에 미치는 영향)

  • Moon, Kyung Im;Lee, Wan Jeong
    • Human Ecology Research
    • /
    • v.54 no.6
    • /
    • pp.611-620
    • /
    • 2016
  • This study examined how parent-child attachment, parental involvement in child rearing and instruction for children's effective use of a smart device reflect on young children's smart device overuse behavior. We collected questionnaires from 196 parents with children attending early childhood education institutions for the survey. Frequency analysis as well as Person correlation coefficient and regression analysis were conducted using IBM SPSS 21.0 statistics. The results showed that 91% of targeted young children were using a smart device and 78% first used them before age 5. As for time of use hours, 43.9% used their smart device from 30 minutes to 1 hour on average. In addition, parent-child attachment and father's involvement in child rearing were found to be inversely correlated to young children's smart device overuse. The result of hierarchical regression analysis on parent factors influencing young children's smart device overuse behavior indicated that mothers' contact-seeking behavior to young children, mother's involvement in learning and instruction for children's effective use of a smart device at home had beneficial effects. This study analyzed parent factors that influenced young children's smart device overindulgence. In addition, the baseline data of this study will be utilized to develop programs for the prevention and therapy to solve the smart device overindulgence as well as to establish young children's guidelines for using a smart device.

CdSe Quantum Dot based Transparent Light-emitting Device using Silver Nanowire/Ga-doped ZnO Composite Electrode (AgNWs/Ga-doped ZnO 복합전극 적용 CdSe양자점 기반 투명발광소자)

  • Park, Jehong;Kim, Hyojun;Kang, Hyeonwoo;Kim, Jongsu;Jeong, Yongseok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.6-10
    • /
    • 2020
  • The silver nanowires (AgNWs) were synthesized by the conventional polyol process, which revealed 25 ㎛ and 30 nm of average length and diameter, respectively. The synthesized AgNWs were applied to the CdSe/CdZnS quantum dot (QD) based transparent light-emitting device (LED). The device using a randomly networked AgNWs electrode had some problems such as the high threshold voltage (for operating the device) due to the random pores from the networked AgNWs. As a method of improvement, a composite electrode was formed by overlaying the ZnO:Ga on the AgNWs network. The device used the composite electrode revealed a low threshold voltage (4.4 Vth) and high current density compared to the AgNWs only electrode device. The brightness and current density of the device using composite electrode were 55.57 cd/㎡ and 41.54 mA/㎠ at the operating voltage of 12.8 V, respectively, while the brightness and current density of the device using (single) AgNWs only were 1.71 cd/㎡ and 2.05 mA/㎠ at the same operating voltage. The transmittance of the device revealed 65 % in a range of visible light. Besides the reliability of the devices was confirmed that the device using the composite electrode revealed 2 times longer lifetime than that of the AgNWs only electrode device.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Development of Knee Weight-bearing Radiography Assist Device (무릎 체중부하 촬영 보조장치 개발)

  • Yon-Lae Kim;Young-Woo Yoon
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.395-399
    • /
    • 2023
  • The knee arthritis patients are generally performed standing position radiography. However, patients with pain caused by degenerative diseases or injuries in the knee have difficulty maintaining a standing position. Therefore, this study aims to develop a knee joint standing weight bearing projection assist device to solve these problems when patients undergo knee radiography due to various diseases. The design of the knee joint weight-bearing radiography assist device is carried out with 3D design and drawing production to secure basic data, electric support and frame manufacture. A fixed device for maintaining the patient's knee standing weight-bearing projection, an electric digital height device, a digital protractor, and a safety device were designed. The arm support is made of PVC with a cushion to relieve the impact and make it easier to remove debris. The digital electric device can be moved up and down according to the patient's height, and a remote control is attached. The safety device is made to be adjustable in size by attaching metal hooks on both sides of the frame and to shield the scrotum. A digital protractor was attached to the side frame to set the desired knee angle. When a self-made assist device was used to perform a knee joint standing weight bearing projection, it helped maintain arm support and lower extremities position. In addition, the height could be adjusted using an assist device during standing projections, which helped the patient maintain the position.

The Development for guideline of raw matrials on technical document of Medical Device (의료기기 허가.기술문서 원자재 작성 가이드라인 개발)

  • Park, Ki-Jung;Ryu, Gyu-Ha;Lee, Sung-Hee;Lee, Chang-Hyung;Jung, Jin-Baek;Lee, Jae-Keun;Hur, Chan-Hoi;Kim, Hyung-Bum;Choi, Min-Yong;Kim, Yong-Woo;Hwang, Sang-Yeon;Jung, Jae-Hoon;Koo, Ja-Jung;Hong, Hye-Kyung;Lim, Kyung-Taek;Kang, Se-Ku;Kwak, Young-Ji
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.434-437
    • /
    • 2010
  • For approval of medical devices manufactured or imported, submission of technical documents as well as the application form is required. The manufacturer (or importer) should properly identify the raw materials the applied product is made of and the manufacturing processes the product undergoes before it is shipped in the application form. In the technical documents, scientific data to evaluate the efficacy, safety, and quality of the applied product that has been described in the application form should be provided. Therefore, identifying the raw materials that were used for the parts of the applied product and describing the physical and chemical characteristics of the raw materials are quite important and essential in ensuring the efficacy, safety, and quality of the applied product. To describe the physical and chemical characteristics of the raw materials correctively, the applicant is required to have broad knowledge in the scientific fields such as chemical, polymer, metal, and ceramic science and engineering. But most of the applicant are not experts in these fields, so that the description in the application form often includes wrong and improper descriptions. Thus, we developed a guideline which explains the raw materials for medical devices, show the their examples. The purpose of this description guideline is to help the applicant properly completing the "Raw materials or constituents and their volumes" part in the application form.

User Satisfaction of Mobile Convergence Device: The Expectation and Disconfirmation Approach (모바일 복합 단말기 사용자 만족: 기대-불일치 접근)

  • Lee, Seung-Chang;Suh, Eung-Kyo
    • Journal of Distribution Science
    • /
    • v.10 no.11
    • /
    • pp.89-99
    • /
    • 2012
  • Purpose - Mobile devices, especially mobile terminals capable of telecommunication and wireless connectivity, are leading the advancements in consumer electronics. Digital convergence drives the functions of various devices, such as cellular phones, MP3 players, personal digital assistants, and gaming, into a single device. This trend would continue and applications such as digital audio and video streaming (including personalized content delivery mechanisms) would soon be on a handheld device. As customers want mobile convergence devices, manufacturers are driving new initiatives in the emerging mobile device market. Given the roles played by device design and service content in user satisfaction of a mobile convergence device, this study focuses on identifying and measuring the constructs for the process by which user satisfaction is achieved. This study synthesizes the expectation-disconfirmation paradigm with empirical theories in user satisfaction. Device and service levels are separated, and nine key constructs for user satisfaction of mobile convergence devices are proposed. Insight into this process could help web-based businesses to improve user satisfaction, thus enhancing the effectiveness of e-commerce for sellers and buyers. Research design, data, methodology - This study draws on three users of mobile convergence devices as examples. To test there search model and hypotheses, survey questionnaires were sent to 607 mobile device users. Mobile device users were initially identified from several members, and subjects were randomly drawn. Data from 577 survey responses were finally analyzed. The unit of measurement and analysis in this research study is at a personal level. Results - The measurements for the constructs were developed and tested in a two-phase study. In the first phase, the device and service dimensions were identified, and instruments for measuring them were developed and tested. In the second phase, using the salient dimensions of the device and service as the formulating first-order factors, instruments were developed and empirically tested to measure satisfaction of the device and service. In measuring satisfaction of mobile convergence devices, the critical tasks are to identify the key constructs of such user satisfaction and to develop validated instruments to measure them. Hence, the results of this study have immediate implications for businesses and for research in user satisfaction of mobile convergence devices. Conclusions - This study provides reliable instruments for operationalizing key constructs in the analysis of user satisfaction of mobile convergence devices within the expectation-disconfirmation paradigm. Hence, convergence device makers will be able to examine whether their websites meet their customers' expectations by examining the device aspect of the mobile convergence device customers, and the service aspect expectations and disconfirmation. Moreover, the introduction of expectation and disconfirmation constructs brings the marketing aspect of convergence devices into focus for such retailers, an aspect crucial to the effective design of websites for online businesses. In addition,this study provides the metrics required to initiate future studies on user satisfaction of mobile convergence devices.

  • PDF

Functional Designs of Metal oxide for Transparent Electronics

  • Kim, Joondong;Patel, Malkeshkumar;Kim, Hong-Sik;Kim, Hyunki;Yadav, Pankaj;Park, Wanghee;Ban, Dongkyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.387.1-387.1
    • /
    • 2016
  • Transparent materials are necessary for most photoelectric devices, which allow the light generation from electric energy or vice versa. Metal oxides are usual materials for transparent conductors to have high optical transmittance with good electrical properties. Functional designs may apply in various applications, including solar cells, photodetectors, and transparent heaters. Nanoscale structures are effective to drive the incident light into light-absorbing semiconductor layer to improve solar cell performances. Recently, the new metal oxide materials have inaugurated functional device applications. Nickel oxide (NiO) is the strong p-type metal oxide and has been applied for all transparent metal oxide photodetector by combining with n-type ZnO. The abrupt p-NiO/n-ZnO heterojunction device has a high transmittance of 90% for visible light but absorbs almost entire UV wavelength light to show the record fastest photoresponse time of 24 ms. For other applications, NiO has been applied for solar cells and transparent heaters to induce the enhanced performances due to its optical and electrical benefits. We discuss the high possibility of metal oxides for current and future transparent electronic applications.

  • PDF