The Effect on Improvement of Muscle Strength Imbalance According to Load Deviation Protocol of Whole Body Vibration Exercise (부하 편차 방식의 전신진동운동이 하지 근력 불균형 개선에 미치는 효과)

  • Seo, Shin Bae;Kang, Seung Rok;Yu, Chang Ho;Min, Jin Young;Kwon, Tae Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1095-1101
    • /
    • 2013
  • The purpose of this study was to verify the effect on improvement of muscle strength unbalance according to load deviation protocol during whole body vibration exercise. Seventeen female volunteers (age $22{\pm}3$ years, height $160{\pm}4.9$ cm, weight $49{\pm}.8$ kg) participated in this experiment. The subjects performed squat exercise in WBV platform. Exercise were performed five set a day including 15 time a set, three days a week, and during 4 weeks. Vibration stimulus was 25Hz as frequency and intensity was dominant leg 1mm and non-dominant leg 4mm. The results in WBV group showed that the differences of peak torque in 16% were getting decreasing significantly after 4 weeks from 16.2% to 5.2%. This result means that WBV with load deviation protocol could provide muscle strength exercise for muscle strength balance. Our study found out that WBV of load deviation protocol could provide muscle strength exercise for improving muscle imbalance.

The Comparison of the KAPM Dosimetric Protocol (1990) with the TG-21 and $C_{\lambda}/C_E$ Method (방사선 선량의 표준 측정법(한국의학물리학회 1990) 및 TG-21, $C_{\lambda}/C_E$ 방법의 비교)

  • Yi, Byong-Yong;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.337-342
    • /
    • 1991
  • The comparison of the KAPM Dosimetric Protocol (1990) with the TG-21 and $C_{\lambda}/C_E$(ICRU-21 and SCRAD protocol) method is studied. The therapetutic range of radiation (photon 4MV-l5MV and electron 6 MeV-20MeV) and three kinds of the chambers were used in the water phantom. The results from 7G-21 and KAPM protocol did not show much differences (less than 1$\%$) throughout the whole energy range; $N_D$ from KAPM protocol and Ngas from TG-21 showed 0.2$\%$ deviation mainly from W/e difference between two protocols. But the results from KAPM protocol (1990) and those from $C_{\lambda}/C_E$ Method showed $-1.9{\pm}0.6\%$ (KAPM protocol is higher) deviation for photom beam and $+3.3{\pm}1\%$ (KAPM protocol is lower) deviation for electron beams.

  • PDF

Traffic Load & Lifetime Deviation based Power-aware Routing Protocol for MANET (MANET에서 트래픽 부하와 노드 수명 편차에 기반한 power-aware 라우팅 프로토콜)

  • Kim, Dong-Hyun;Ha, Rhan
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.5
    • /
    • pp.395-406
    • /
    • 2006
  • In ad hoc networks, the limited battery capacity of nodes affects a lifetime of network Recently, a large variety of power-aware routing protocols have been proposed to improve an energy efficiency of ad hoc networks. Existing power-aware routing protocols basically consider the residual battery capacity and transmission power of nodes in route discovery process. This paper proposes a new power-aware routing protocol, TDPR(Traffic load & lifetime Deviation based Power-aware Routing protocol), that does not only consider residual battery capacity and transmission power, but also the traffic load of nodes and deviation among the lifetimes of nodes. It helps to extend the entire lifetime of network and to achieve load balancing. Simulations using ns-2[14] show the performance of the proposed routing protocol in terms of the load balancing of the entire network, the consumed energy capacity of nodes, and an path's reliability TDPR has maximum 72% dead nodes less than AODV[4], and maximum 58% dead nodes less than PSR[9]. And TDPR consumes residual energy capacity maximum 29% less than AODV, maximum 15% less than PSR. Error messages are sent maximum 38% less than PSR, and maximum 41% less than AODV.

Marginal and internal fit of all ceramic crown using the replica technique and the triple-scan protocol (Replica technique과 Triple-scan protocol을 이용한 지르코니아 전부도재관의 변연 및 내면 적합도에 관한 비교 연구)

  • Shin, Mi-Sun;Lee, Jang-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.372-380
    • /
    • 2017
  • This study was conducted to compare the marginal and internal fit of all ceramic crown using the replica technique and the triple-scan protocol. Materials and methods: Twenty zirconia ceramic crowns were fabricated using titanium abutment model. All crowns were divided into two groups of 10 each, depending on the replica technique and the triple-scan protocol. The internal and marginal fit of 10 zirconia ceramic crowns were measured at 17 points for each specimen using the replica technique. The other 10 ceramic crowns were measured using the triple-scan protocol. Statistical analysis was performed by t-test (${\alpha}=.05$). Results: The mean and standard deviation of marginal and internal fit were significantly different between the replica technique ($49.86{\pm}29.69{\mu}m$) and triple-scan protocol ($75.35{\pm}64.73{\mu}m$, P<.001). The mean and standard deviation of internal fit except marginal fit were $58.38{\pm}31.77{\mu}m$ and $64.00{\pm}46.43{\mu}m$, respectively (P>.343). Conclusion: There was a statistically significant difference in the marginal fit measured by the two methods. However, there was no statistically significant difference in the internal fit between the two methods.

The Crucial Role of the Establishment of Computed Tomography Density Conversion Tables for Treating Brain or Head/Neck Tumors

  • Yang, Shu-Chin;Lo, Su-Hua;Shie, Li-Tsuen;Lee, Sung-Wei;Ho, Sheng-Yow
    • Progress in Medical Physics
    • /
    • v.32 no.3
    • /
    • pp.59-69
    • /
    • 2021
  • Purpose: The relationship between computed tomography (CT) number and electron density (ED) has been investigated in previous studies. However, the role of these measures for guiding cancer treatment remains unclear. Methods: The CT number was plotted against ED for different imaging protocols. The CT number was imported into ED tables for the Pinnacle treatment planning system (TPS) and was used to determine the effect on dose calculations. Conversion tables for radiation dose calculations were generated and subsequently monitored using a dosimeter to determine the effect of different CT scanning protocols and treatment sites. These tables were used to retrospectively recalculate the radiation therapy plans for 41 patients after an incorrect scanning protocol was inadvertently used. The gamma index was further used to assess the dose distribution, percentage dose difference (DD), and distance-to-agreement (DTA). Results: For densities <1.1 g/cm3, the standard deviation of the CT number was ±0.6% and the greatest variation was noted for brain protocol conditions. For densities >1.1 g/cm3, the standard deviation of the CT number was ±21.2% and the greatest variation occurred for the tube voltage and head and neck (H&N) protocol conditions. These findings suggest that the factors most affecting the CT number are the tube voltage and treatment site (brain and H&N). Gamma index analyses for the 41 retrospective clinical cases, as well as brain metastases and H&N tumors, showed gamma passing rates >90% and <90% for the passing criterion of 2%/2 and 1%/1 mm, respectively. Conclusions: The CT protocol should be carefully decided for TPS. The correct protocol should be used for the corresponding TPS based on the treatment site because this especially affects the dose distribution for brain metastases and H&N tumor recognition. Such steps could help reduce systematic errors.

Molecular Dynamics Free Energy Simulation Study to Rationalize the Relative Activities of PPAR δ Agonists

  • Lee, Woo-Jin;Park, Hwang-Seo;Lee, Sangyoub
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.363-371
    • /
    • 2008
  • As a computational method for the discovery of the effective agonists for PPARd, we address the usefulness of molecular dynamics free energy (MDFE) simulation with explicit solvent in terms of the accuracy and the computing cost. For this purpose, we establish an efficient computational protocol of thermodynamic integration (TI) that is superior to free energy perturbation (FEP) method in parallel computing environment. Using this protocol, the relative binding affinities of GW501516 and its derivatives for PPARd are calculated. The accuracy of our protocol was evaluated in two steps. First, we devise a thermodynamic cycle to calculate the absolute and relative hydration free energies of test molecules. This allows a self-consistent check for the accuracy of the calculation protocol. Second, the calculated relative binding affinities of the selected ligands are compared with experimental IC50 values. The average deviation of the calculated binding free energies from the experimental results amounts at the most to 1 kcal/mol. The computational efficiency of current protocol is also assessed by comparing its execution times with those of the sequential version of the TI protocol. The results show that the calculation can be accelerated by 4 times when compared to the sequential run. Based on the calculations with the parallel computational protocol, a new potential agonist of GW501516 derivative is proposed.

Validation of the Detailed Design of the Label Distribution Protocol for the Multiprotocol Label Switching System (Multiprotocol Label Switching System의 Label Distribution Protocol 상세설계 검증)

  • 박재현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.5A
    • /
    • pp.889-901
    • /
    • 2001
  • 본 논문에서 Multiprotocol Label Switching 시스템을 위한 Label Distribution Protocol의 개발과 분석에 관해서 기술한다. 먼저 Gigabit Switched Router를 만들기 위해서, 상용화시 Carrier Class 제품에 적용하기 위한 LDP의 구현시 고려해야 될 사항에 대해 살피고, 상세 설계를 제안한다. IETF 표준에 의거한 LDP의 구현을 위한 상세 설계는 프로토콜 상태기계의 유도 트리와 프로세스 대수를 사용한 형식적 명세를 사용하여 제시한다. 본 논문에서는 제시된 유도트리와 프로세스 대수를 사용한 프로토콜 동작의 분석을 통해, 구현된 LDP의 상호 연동성과 완전성, 생존성, 도달성, 안전성을 검증한다. 또한 이를 사용하여 구현된 LDP가 기존 상용 제품들과의 연동성과 그 동작의 신뢰성을 확보할 것을 기대한다. 결과적으로 구현된 LDP의 프로토콜 동작들의 검증을 제공한다.

  • PDF

Enhancing TCP Performance to Persistent Packet Reordering

  • Leung Ka-Cheong;Ma Changming
    • Journal of Communications and Networks
    • /
    • v.7 no.3
    • /
    • pp.385-393
    • /
    • 2005
  • In this paper, we propose a simple algorithm to adaptively adjust the value of dupthresh, the duplicate acknowledgement threshold that triggers the transmission control protocol (TCP) fast retransmission algorithm, to improve the TCP performance in a network environment with persistent packet reordering. Our algorithm uses an exponentially weighted moving average (EWMA) and the mean deviation of the lengths of the reordering events reported by a TCP receiver with the duplicate selective acknowledgement (DSACK) extension to estimate the value of dupthresh. We also apply an adaptive upper bound on dupthresh to avoid the retransmission timeout events. In addition, our algorithm includes a mechanism to exponentially reduce dupthresh when the retransmission timer expires. With these mechanisms, our algorithm is capable of converging to and staying at a near-optimal interval of dupthresh. The simulation results show that our algorithm improves the protocol performance significantly with minimal overheads, achieving a greater throughput and fewer false fast retransmissions.

A Study on a Ranging Protocol for the ATM-PON Based ell ITU-T G.983.1 (G.983.1 기반의 ATM-PON을 위한 Ranging 프로토콜에 관한 연구)

  • Chung, Hae;Kim, Jin-Hee;Kwun, Sun-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 2000
  • ATM PON system is regarded as a solution of the next generation access network because it can cover various types of subscribers in a single platform. In this paper, we describe the merit of the ATM PON and the key protocols for its operation. Above all, the ranging is the most important protocol providing a mean of the time-division multiple access in the system. A problem in the protocol is that the window size, the time interval that ranging cell arrives, is too long. During the interval, user traffics cannot be send to the upstream, which makes the quality of service degraded. In this paper, we suggest a method to minimize the window size when the length of the optic fiber is known with some deviation. The window size can be reduced as 7 % of the conventional method when the deviation of the length is 1 Km.