• 제목/요약/키워드: Deterioration Factor

검색결과 396건 처리시간 0.022초

Public Building Value Evaluation Using Contingent Valuation Method Based on Market Value Estimation

  • PARK, Jieun;YU, Jungho
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.367-370
    • /
    • 2015
  • Building deterioration reflects the degradation of basic building performance including structural performance, energy performance, durability, and safety, and it also includes perceived deterioration, which considers a user-based perspective. More than 50% of the existing buildings in Korea are over 15 years old and public buildings compose 2.5% of all buildings domestically. Therefore, there are several different problems, such as poor energy efficiency, structural performance, and safety. To address the challenges of increasing stock in deteriorated buildings, it is necessary to make decisions about reconstruction or renovation. In this study, we propose a new method to evaluate public building value with a contingent valuation method (CVM). By estimating willing-to-pay (WTP) from users of private buildings in similar situation with the public building, it is possible to compare market prices and calculate a correction factor to adjust the WTP data. Finally, we apply the correction factor to the WTP of a public building and estimate market price, willingness to pay (WTP). Finally, we apply the correction factor to willing to pay (WTP) of public building and estimate market price.

  • PDF

알칼리부여제의 회복에 따른 시멘트 경화체의 충진성에 관한 실험적 연구 (An Experimental Study on the Packing Ability of Hardened Cement Paste According to Penetrate by Alkalization Agent)

  • 김광기;공민호;박선길;김우재;송병창;정강진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.823-828
    • /
    • 2002
  • Concrete used up to date semipermanent architecture material but now day concrete early deterioration emboss social issue because of construction structure and environmental factor. so, many study of deterioration concrete construction improve durability used impregnation alkalization agent. Impregnation alkalization agent deterioration concrete construction spray infiltration or diffusion improve alkali and filler inter minuteness void elaborateness constitution concrete. but many study of harding concrete change inter minuteness void that Is insufficiency also, To study of method recover shape impregnation alkalization agent apply deterioration concrete construction. impregnation alkalization agent infiltration according to test of porosity, premeameter, absorption.

  • PDF

동결융해 작용을 받은 콘크리트의 촉진중성화 특성 (Accelerated Carbonation of Concrete Deteriorated by Freezing and Thawing)

  • 손유신;김규용;김한준;박찬규;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.221-224
    • /
    • 2004
  • Several factors of concrete durability decline factor are acted as complex deterioration and is happened not that happen by simplicity deterioration. Specially, in case of sea construction, as complex salt damage, carbonation and freezing & thawing, concrete surface and pore structure is deteriorated. Therefore, analyzing concrete carbonation and pore structure after freezing and thawing test by fresh water and sea water in this research, we wish to study about acceleration of decline of durability and complex deterioration by concrete surface deterioration in sea environment.

  • PDF

대도시 지역의 노후 조적조 건축물의 구조 성능 열화 특성 분석 (An Analysis on the Structural Deterioration Properties of Timeworn Masonry Buildings in Metropolitan Area)

  • 권기혁;이경용;양희숙
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.181-189
    • /
    • 2003
  • 1960~70년대에 시작된 대도시 인구 집중화로 인해 다수의 조적조 건축물이 시공되었으며, 현재 이들은 상당수 구조 성능 저하 현상이 발생하고 있다. 노후 조적조 건축물의 특성 분석을 통해 벽체에서 발생하는 균열들이 가장 큰 열화요인이며 그 다음으로 큰 영향을 주는 요인은 기초로 분석되었으며, 열화 정도와 진행 속도는 사용유형, 시공년도와 큰 상관관계가 있는 것으로 분석되었다. 또한, 건물의 존치기간이 길어짐에 따라 전체적인 안전수준을 떨어지게 되는데 조적조 건축물에 있어서 열화 정도의 한계에 이르는 시기는 존치기간 30년으로 분석되었다.

계층적분석과정을 이용한 상수관로의 노후도 평가를 위한 항목별 가중치 산정 (Estimation of Deterioration Assessment for Weighting Factors in Pipes of Water Supply Systems Using Analytic Hierarchy Process)

  • 김응석
    • 한국방재학회 논문집
    • /
    • 제8권5호
    • /
    • pp.15-21
    • /
    • 2008
  • 본 연구의 목적은 현재 지방자치단체에서 수행하는 상수관로 개량 및 교체 사업시 상수관로의 노후도 평가를 위한 항목별 가중치를 산정하는 것이다. 상수도시스템에 상수관로의 노후도 항목은 지역 및 위치, 토지이용 등의 특성에 영향을 받을 수 있다. 본 연구에서는 국내외 자료를 바탕으로 국내 실정에 맞는 노후도 항목 16개를 선정하였다. 또한, 노후도 항목별 세분화된 가중치 산정을 위해 실무업체를 선정하여 해당 전문가들을 대상으로 노후도 항목별 중요도에 대한 설문을 실시하였다. 설문 조사 방법으로는 델피법을 이용하여 이 결과를 바탕으로 계층적분석과정(AHP)을 적용하여 노후항목별 가중치를 산정하였다. 분석결과 국내 실무에 적합한 16개 결함항목별 점수배점표를 작성하여 명확한 판단기준을 마련하였으며 관거 개량사업에 있어서 복잡한 의사결정 문제들에 대한 활용 가능성을 제시하였다.

교육시설의 옥상방수 열화도 진행 모델에 관한 연구 (A Study on the Establishment of the Deterioration Process Model of Roof Waterproofing in the Education facilities)

  • 이강희;채창우;류수훈
    • 교육시설 논문지
    • /
    • 제24권6호
    • /
    • pp.11-18
    • /
    • 2017
  • Education facilities have much affect to make a good condition for the learning environment. Therefore, various approaches have been conducted to improve the physical, social and educational achievement. Especially, the physical aspect is very important to get rid of the building defect and improve the student their learning environment. For these, it needs to explain the performance and function of components and materials, which is linked with the deterioration degree. The deterioration degree is a imperative factor to make a decision whether the component would be repaired or not and to provide the repair scope of its component. In this paper, it aimed at making the deterioration degree model of roof proof under the hypothesis of which deterioration degree would be equal the repair cost at this time. Results of the study are shown that first, the $3^{rd}$ function is most proper to explain the deterioration degree model among 11 functions in view of resulted statistics. Second, the inflection of deterioration is shown at 15yr of the elementary school and 13yr of the middle and high school. This study has a limit of disclassification of the component or materials and it is, therefore, favorable to include the classification of waterproof material and work. These results would make a change from the breakdown maintenance to preventive maintenance and give a decent the learning environment for student.

사면의 지반 열화로 인한 안정성 평가에 관한 연구 (A Study on the Evaluation of Stability due to Ground Deterioration of Slope)

  • 한영철
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.83-92
    • /
    • 2018
  • 사면 구조물은 시간이 경과함에 따라 대상지반에서 각종 열화 현상이 진행되어 내구성의 저하로 인한 붕괴가 발생할 수 있으며, 사용 연한을 감소시키는 결과를 초래하게 된다. 이러한 지반 열화에 따른 사면안정에 대한 접근방안은 지반의 물리적 특성 및 기하학적인 구조에 국한하여 분석하는 기존의 한계 평형 해석과는 또 다른 개념이라 할 수 있다. 본 연구에서는 사면의 열화 특성과 관련하여 각종 문헌 조사를 통하여 비교분석을 수행하고, 전단강도 저감에 대한 최적의 제안식들로서 지수함수, 로그함수 및 역쌍곡선 함수를 제시하고, 열화에 취약한 양산 단층대의 셰일층에서 붕괴가 발생한 경부고속철도 절토사면을 대상으로 사례분석을 실시하였다. 본 연구에서는 사례분석을 통하여 향후 열화로 인한 사면 안전성과 관련하여 정량적인 평가를 위한 최적의 강도 저하 곡선을 도출하고 한계평형해석에 의한 안정해석을 할 수 있는 접근 방법을 제시하였다.

목재문화재의 열화에 대한 고찰 (Degradation and Preservation of wood)

  • 김익주
    • 보존과학연구
    • /
    • 통권7호
    • /
    • pp.265-277
    • /
    • 1986
  • The degradation of wood is maimly caused by biological and thermal factor. In general, the field of wood preservation can be divided into two broadcategories; namely the deterioration, protection of wood, and the teatment of wood with preservatives. Wood in sea or brackish water incurs marine borer damage, consisting of attack by marine animal and also wood on land suffers severely from insect damage. But the largest wood degradation is caused by microorganism. Animals that attack wood in a marine environment are especially destructive in warm water-regions, little was achieved in their control recently. Therefore this manuscript only introduce the importance of wood deterioration caused by marine animal.

  • PDF

배수관 내시경 조사를 통한 간접적인 관 노후도 평가방법의 적정성 연구 (A Study on Adequacy of Pipe Deterioration Evaluation Methods using the Endoscope of Water Distribution Pipe)

  • 최태호;강신재;최재호;구자용
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.669-683
    • /
    • 2012
  • The water supply pipes are buried across wide range of areas, so it is hard to spot them using excavation and takes a large amount of expense. Thus, there is a high risk for direct research and application, accompanying many difficulties in implementation of them. Therefore, it is more economical and convenient to use indirect evaluation variables than direct evaluation of the buried pipes in assessing the degree of pipe deterioration. To assess the degree of pipe deterioration using the indirect evaluation variables, it should be done first to identify how and to what extent they affect the degree of deterioration. This study measured the evaluation variables for pipe deterioration using the pipe endoscope and analyzed the measurement results and the degree of impact on the pipes. In addition, this study attempted to evaluate the adequateness of the pipe deterioration evaluation using the indirect variables based on the analysis results. The evaluation variables measured through the pipe endoscope were the thickness of sediments, size of scale, degree of desquamation and condition of connections. For the indirect evaluation variables, the data such as the property data from GIS pipe network map as well as the material, diameter, age and pipe lining material of the pipe, road type, leakage frequency, average water velocity and water pressure using the leakage repair records was collected. Using the collected data, this study comparatively analyzed the indirect evaluation variables for the degree of pipe deterioration and the results from the pipe endoscope to choose appropriate variables for pipe deterioration evaluation and calculated the weights of the indirect variables on the degree of deterioration. The results showed that the order of the impact of indirect variables on deterioration was pipe age > pipe lining material > road type > leakage frequency > average water velocity with their weights of 0.45, 0.20, 0.15, 0.10, and 0.10, respectively. Conclusively, the results suggest that the measures of sediment thickness, scale size, degree of desquamation and condition of connections are appropriate for the evaluation of pipe deterioration and sufficient for the analysis of the impact of the indirect variables on deterioration.

콘크리트와 이형철근의 계면 부착성능 : 상단철근 및 에폭시도막철근 효과 (A Study on Interfacial Bond Capacity of Deformed Bars to Concrete : Top Bars and Epoxy-Coated Bars)

  • 강석원;홍건호;정일영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.204-209
    • /
    • 1995
  • The influence of the interfacial properties on the bond capacity of reinforcing bars to concrete is studied in this paper. In this study, the deterioration of the interfacial bond capacity when top-cast bars or epoxy-coated bars are used is examined. The effect of such variables on bond capacity in reinforced concrete is studied by experiment which use beam-end specimens. The main objective of this study is that comparing the test results and the requirements in ACI 318-89 code. the verification of the factor in ACI code is also presented in this paper. The results of the test show that "top bar effect" is considerably affected by the slump of fresh concrete, so the influence of slump shoud be taken into account for top bar effect factor in code. Test results also shows that the bond-slip curve of the epoxy-caoted bars is similiar to that of the uncoated and bond strength is reduced about 15% and that coating thickness seems to influence the bond strength deterioration.rioration.

  • PDF