• Title/Summary/Keyword: Deterioration

Search Result 5,205, Processing Time 0.028 seconds

Building mix design and quality control measures to reduce the combined deterioration of plain concrete in harsh environments (혹독한 환경에서의 무근콘크리트 복합열화 저감을 위한 배합설계 및 품질관리 방안 구축)

  • Kim, Dae-Geon;Park, Chan-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.85-86
    • /
    • 2016
  • Recently damages caused by the additional costs and degradation in durability combined deterioration due to plain concrete deterioration has occurred. In particular, in the case of the finish that is not exposed to the outside air in the concrete to respond to the harsh environment (freeze-thawing, calcium laying, etc.), to establish a quality control way for the process and the concrete mix design for it.

  • PDF

Surface Deterioration Phenomena in Polyethylene under Corona Discharge (Corona 방전에 의한 Polyethylene의 표면열화현상)

  • 성영권;송진수;민남기
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.82-90
    • /
    • 1975
  • This study investigated the deterioration phenomena of the Polyethylene surface contaminated with organic(Saccharose) or inorganic(NaCl) matters through electrical and optical experiments. And also these experimental results relatively well coincided with which was treated by theoretical process. On the electrical experiment, relation between electric field intensity in corona discharge and time reached to the breakdown, and relation between total amount of charges discharged and increment of applied voltage were investigated. On the optical experiment, discharge time dependence of surface deterioration rate and process of surface deterioration in the X-ray diffraction pattern were investigated. It was concluded that chemical effects by the corona discharge deteriorated insulation characteristics of Polyethylene surface.

  • PDF

A Study on the Reduction of Combined Deterioration by Mixing Latex in Base Concrete (바탕콘크리트의 라텍스 혼입에 따른 복합열화 저감에 관한 연구)

  • Kim, Dae-Geon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.101-102
    • /
    • 2023
  • This study aims to mix the base concrete by mixing latex to improve the durability performance to reduce the composite deterioration of the base concrete. Latex fiber has high resistance to freezing and thawing, adhesion, and deicing agent (calcium chloride), and it is used to secure long-term durability to reduce cracking and compound deterioration of concrete. In addition, through experiments, we are trying to find ways to improve the strength of concrete by studying the mixing of the appropriate mixing ratio of latex.

  • PDF

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

Estimation of Deterioration Assessment for Weighting Factors in Pipes of Water Supply Systems Using Analytic Hierarchy Process (계층적분석과정을 이용한 상수관로의 노후도 평가를 위한 항목별 가중치 산정)

  • Kim, Eung-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.15-21
    • /
    • 2008
  • The purpose of this study is to estimate deterioration assessment for weighting factors in pipe network for which each local selfgovernment takes rehabilitation and replacement work at present time. Deterioic hierarchy process(AHP), calculates the weighting factors. The appropriate marks matrix of sixteen deterioration factors are made for the precise decision standard of pipe condition through the result of this analysis. The marks matrix of sixteen deterioration factors can solve the complicated decision making problems of pipe rehabilitation workration factors in the pipe network might be influenced by local factors, such as province, location, or land use, in water supply systems. In this study, the sixteen deterioration factors are determined suitable for domestic situation based on the pipe deterioration factor data inside and outside of the country. Also, we select persons in charge of calculating the detail weighting factors and do survey about important level of each deterioration factors. Delphi method, a question survey method applying the analyts.

Effects of Selected Stabilizers on the Color Deterioration of Crude Pigment Extract from Schizandra fruit (Schizandra Fructus) (여러 가지 안정화 물질이 오미자 색소 추출물의 가열 변색에 미치는 영향)

  • Kim, Hyun-Jung;Cho, Sung-Bin;Chun, Hyang-Sook
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.5
    • /
    • pp.475-482
    • /
    • 2003
  • The effects of selected stabilizers and sugars on color deterioration of anthocyanin in Schizandra fructus were examined at $100^{\circ}C$ for $120{\sim}180$ min. Among four test sugars, it was found that fructose accelerated the thermal color deterioration while maltose retarded the color deterioration by 40%. Maltodextrin and ${\gamma}$-cyclodextrin showed the highest stabilizing effect on the thermal color deterioration of crude pigment extract from Schizandra fructus(CPES) containing 2 mg% of anthocyanin. Addition of maltodextrin or ${\gamma}$-cyclodextin at 5% retarded thermal color deterioration of CPES. In gel system, 5% of maltodextrin also retarded the color deterioration by $15{\sim}20%$ during storage at $25^{\circ}C\;and\;35^{\circ}C$.

A Study on the Evaluating Indicators of the Level of Deterioration in High-rise and high-density Apartments (고층고밀 아파트단지의 노후도 평가지표 개발)

  • Cho, Sung-Heui;Lee, Tae-Kyung
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.131-142
    • /
    • 2009
  • High-rise and high-density apartment complexes have been built and supplied on a large scale in the 1st period of the New Town project in metropolitan areas since the late 1980s. Now It has become necessary to improve those apartment complexes, which have serious deterioration problems for aging more than about 20 years accompanying simultaneity and a large scale. The purpose of this research is to develop the evaluating indicators to measure the level of deterioration of apartments inclusively and practically in order to regenerate apartments as sustainable residential environments. This study is composed of the following four parts; (a) establishing the conceptual model of evaluation of apartment deterioration, (b) selecting evaluation items, (c) constituting evaluation measurement, and(d)weighting evaluation indicators. First, deterioration of apartments was conceptualized by physical. social, and economical aspects in terms of sustainable development and proposed the conceptual model of hierarchy structure of evaluation of apartment deterioration by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about apartments of Korea and foreign countries. The evaluating indicators were identified as a total of 77 evaluating items which were composed of three dimensions and 9 attributes on the basis of the conceptual model. They cover comprehensive scope of the apartment such as unit, building, complex, and site. Third, as the measurement, the 5 point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was analyzed by AHP method conducted by survey on the expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The evaluation of the level of deterioration can be done by both total evaluation and a specific field of evaluation. In addition, it is easy to grasp deteriorated attributes or dimensions by providing a radar and bar chart showing evaluation results. These evaluating indicators could be a useful tool to grasp actual methods for the regeneration of apartments.

A Study on the Establishment of the Deterioration Process Model of Roof Waterproofing in the Education facilities (교육시설의 옥상방수 열화도 진행 모델에 관한 연구)

  • Lee, Kang-Hee;Chae, Chang-U;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.11-18
    • /
    • 2017
  • Education facilities have much affect to make a good condition for the learning environment. Therefore, various approaches have been conducted to improve the physical, social and educational achievement. Especially, the physical aspect is very important to get rid of the building defect and improve the student their learning environment. For these, it needs to explain the performance and function of components and materials, which is linked with the deterioration degree. The deterioration degree is a imperative factor to make a decision whether the component would be repaired or not and to provide the repair scope of its component. In this paper, it aimed at making the deterioration degree model of roof proof under the hypothesis of which deterioration degree would be equal the repair cost at this time. Results of the study are shown that first, the $3^{rd}$ function is most proper to explain the deterioration degree model among 11 functions in view of resulted statistics. Second, the inflection of deterioration is shown at 15yr of the elementary school and 13yr of the middle and high school. This study has a limit of disclassification of the component or materials and it is, therefore, favorable to include the classification of waterproof material and work. These results would make a change from the breakdown maintenance to preventive maintenance and give a decent the learning environment for student.

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Analysis of Physical Characteristics and Deterioration Type of Trail in National Parks (국립공원 탐방로의 물리적 특성 및 훼손유형 분석 - 6개 국립공원을 대상으로 -)

  • Jeong, Won-Ok;Ma, Ho-Seop;Kang, Won-Seok
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.17-27
    • /
    • 2012
  • The purpose of this study is to analyze the trail deterioration condition and to obtain the information for the desirable maintenance and restoration of trail in national parks. The results obtained from this study were summarized as follows; The physical characteristics of trail were surveyed at the total 778 point for 204.5 km in length. As a result, the average degree of trail was $14.6^{\circ}$, average trail width was 1.5m and average bared trail width was 1.1 m. Major deterioration types of trail were trail deepen (37%), root exposed, widen, diverged, rock exposed and slope erosion in order of frequency. Deterioration class of trail were that non-deterioration was 165.34 km (80.9%), heavy class was 9.08 km, middle class was 12.69 km and light class was 17.39 km and the deterioration rate was 19.1%.