• Title/Summary/Keyword: Detection limits

Search Result 938, Processing Time 0.034 seconds

The detection limits to antibiotic drugs in treatment of mastitis by TTC II redution test (TTC II 검사항법을 이용한 유방염치료제의 최소검출농도)

  • 조옥숙;도재철;김기철;이상명;정종식
    • Korean Journal of Veterinary Service
    • /
    • v.23 no.4
    • /
    • pp.335-340
    • /
    • 2000
  • The study was Investigated detectable limits of antibiotic drugs in treatment of mastitis by TTC II reduction test. The detectable limits of antibiotic drugs by TTC II reduction test were summarized as follows, 1. Detectable limits to compounds drugs were higher than those of monodrugs. 2. Detectable limits to ointments were lower than injections.

  • PDF

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Comparison of IHNV Detection Limits by IMS-RT-PCR, Western Blot and ELISA

  • Kim Soo-Jin;Lee Eun-Young;Oh Myung-Joo;Choi Tae-Jin
    • Fisheries and Aquatic Sciences
    • /
    • v.4 no.1
    • /
    • pp.32-38
    • /
    • 2001
  • Several molecular biological techniques have been used to detect virus rapidly and accurately, but these methods have limitations in the early stage of viral infection with very low concentration of virus. We compared the detection limits of IMS-PCR, Western blot and ELISA with infectious hematopoietic necrosis virus OHNV). Four antibodies, rabbit anti-IHNV polyclonal antibody, anti-IHNV nucleocapsid protein monoclonal antibody, anti-IHNV nucleocapsid protein polyclonal antibody, and anti-IHNV glycoprotein polyclonal antibody, were tested to find out the most effective antibody for each method. The detection limit with IMS- PCR was $2\times10^6$ pfu when the viral RNA was extracted before RT-PCR. In the western blot with rabbit anti­IHNV polyclonal antibody one pfu of virus could be detected. In ELISA, 10 pfu of virus particles were detected with the same antibody.

  • PDF

Characterization of Atomic Emission Detector for Gas Chromatography Using Cylindrical Microwave Cavity (원통형 Microwave Cavity를 이용한 기체크로마토그라프 원자발광 검출기의 특성에 관한 연구)

  • Park, Young-Joo;Yoo, Hee-Soo
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.263-268
    • /
    • 1992
  • A plasma source with cylindrical microwave cavity was used as atomic emission detector for gas chromatography. Detection limits of several elements were determined for this system. Detection limits for bromine and sulfur were 0.46 pg/s and 0.51 ng/s, respectively. The plasma was stable at the range of flow rate of 10 to 20mL/min.

  • PDF

PD Source Detection of Oil Transformer Using Three-dimensional Construction (3차원 해석에 의한 유입변압기 PD발생점 탐지)

  • Yoon, Chul-Sub;Choi, Gil-Soo;Lee, Eun-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1036-1038
    • /
    • 1998
  • The while, PD source detection in the oil TR was the level of the planar source detection. and it is to respected scientific research. The planar source detection technique had limits which have difficulties finding out the point of deterioration generation. In this study, our purpose is a development of PD source detection technique with Three-Dimensional using a principle and a technique of the planar source location.

  • PDF

An Experimental Estimation of Two Detection Limit Models

  • Ma Chang-Jin;Tohno Susumu;Kasahara Mikio;Kang Gong-Unn
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E1
    • /
    • pp.29-33
    • /
    • 2004
  • In environmental studies, decisions are often made on the analytical data indicating certain contaminants as being 'detected' or 'non-detectible.' Since detection limits are analytical method specific, one has to first review the concepts and definitions associated with analytical method systems and specifications. In this study, the experimental analytical values for a series of low level standards (for an ionic species) were used as an example to estimate two different method detection limits (MDL). The scores of EPA's MDL and Pallesen's MDL determined by real analytical scores are 0.0575 and 0.0561 mg/L, respectively for our nitrate data. These scores determined by two different MDL models are roughly similar, while there are apparent differences between two methods with respect to statistical and systematical procedure. However, determination of MDL for one's laboratory provides some practical applications which helps to assure one's regulating authorities that one's measured scores are accurate.

A Sensitive Fluorescent Detection Method for Prostaglandins by High Performance Liquid Chromatography (고속액체크로마토그라피에 의한 프로스타글란딘류의 고감도 형광 분석법)

  • Lee, Yong-Moon;Moon, Dong-Cheul
    • YAKHAK HOEJI
    • /
    • v.36 no.5
    • /
    • pp.506-511
    • /
    • 1992
  • The Prostaglandins were derivatized rapidly with monodansyl cadaverine as a fluorophore in mild conditions. The carboxylic moiety of prostaglandins was activated with diethyl phosphorocyanidate and successively coupled with fluorophore in dimethylformamide at room temperature. The labeling yield was reached about 95% at 15 min using arachidic acid $(C_{20:0})$ as a test sample. This derivative showed constant fluorescent intensity at $4^{\circ}C$ for 180 days. The derivatives of prostaglandins were shown high solvent selectivity with tetrahydrofuran in reversed-phase column. therefore, these derivatives could be successfully separated on YMC pack A-212(S-5 120A C8) column in tetrahydrofuran-based eluents. The detection limits of these derivatives was ca. 500 fmol and determination limits was ca. 5 pmol as injected amount in fluorescent detection $({\lambda}ex.\;340\;nm,\;{\lambda}em.\;520\;nm)$. In this method, the ranges of recovery and coefficient of variation were $93.6{\sim}102.7%$ and $4.3{\sim}5.8%$, respectively.

  • PDF

Isolation and Quantitative Analysis of Tricin from Ears of Phragmites communis (갈대이삭으로부터 Tricin의 분리 및 함량 분석)

  • Woo, Hyun Sim;Lee, Seung-Young;Hwang, Buyng Su;Jeong, Sang-Chul;Kim, Dae Wook
    • Korean Journal of Pharmacognosy
    • /
    • v.48 no.1
    • /
    • pp.77-81
    • /
    • 2017
  • The aim of this study was to investigate a validation method for determination of tricin in Phragmites communis ears. Tricin was isolated with chromatographic methods and used as the standard substances for quantitative analysis. The structural determination was characterized by comparing their NMR spectral data with values reported in the literature. For validation, the specificity, linearity, precision, accuracy, detection limits, and quantification limits of tricin was measured by HPLC. The results show that the specificity was satisfied with retention time and diode array detector (DAD) spectrum by analysis of tricin using HPLC. The limits of detection (LOD) for tricin was 0.84 mg/ml. Recovery of tricin was 98.80~108.22% with R.S.D values less than 2%. Intra-day and inter-day precisions of tricin in P. communis ears were 99.96~100.96% and 99.01~100.40%, respectively. Therefore, application of tricin was validated by an analytical method as major compound in P. communis ears.

Biosensor for Detection of Yersinia enterocolitica based on imaging ellipsometry (이미지 엘립소미트리를 이용한 예시니아 검출용 바이오센서 개발)

  • Y. M. Bae;Park, K. W.;Park, J. W.;S. I. Cho
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.421-426
    • /
    • 2003
  • The Immunosensor based on antigen-antibody binding have been developed for detecting several analytes including antigen, small molecules, and cell. This method can be rapid and show very good detection limits. For Implementation of immunosensor, technologies for immobilization of antibody onto solid surface and detection of protein-protein binding must be developed. (an ellipsis)

  • PDF