Comparison of IHNV Detection Limits by IMS-RT-PCR, Western Blot and ELISA

  • Kim Soo-Jin (Department of microbiology, Pukyong National University) ;
  • Lee Eun-Young (Department of microbiology, Pukyong National University) ;
  • Oh Myung-Joo (Department of Fish Pathology, Yosu National University) ;
  • Choi Tae-Jin (Department of microbiology, Pukyong National University)
  • Published : 2001.03.01

Abstract

Several molecular biological techniques have been used to detect virus rapidly and accurately, but these methods have limitations in the early stage of viral infection with very low concentration of virus. We compared the detection limits of IMS-PCR, Western blot and ELISA with infectious hematopoietic necrosis virus OHNV). Four antibodies, rabbit anti-IHNV polyclonal antibody, anti-IHNV nucleocapsid protein monoclonal antibody, anti-IHNV nucleocapsid protein polyclonal antibody, and anti-IHNV glycoprotein polyclonal antibody, were tested to find out the most effective antibody for each method. The detection limit with IMS- PCR was $2\times10^6$ pfu when the viral RNA was extracted before RT-PCR. In the western blot with rabbit anti­IHNV polyclonal antibody one pfu of virus could be detected. In ELISA, 10 pfu of virus particles were detected with the same antibody.

Keywords