• Title/Summary/Keyword: Detachable Type

Search Result 42, Processing Time 0.023 seconds

Characteristics of the ㄷ ㅓ Type Core for Contactless Battery Charger (비접촉식 충전 장치를 위한 ㄷㅓ 형 코어에 관한 연구)

  • Jeon, Sung-Jeup;Heo, Jun;Lee, Kwang-Woon;Cho, Kyu-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.407-417
    • /
    • 2003
  • Detachable transformers used in contactless battery chargers have poor power transfer characteristics because they have low coupling coefficients due to their gaps. The ㄷㅓ type core gives a high coupling coefficient in a contactless battery charger compared with standard cores such as EE, EC and UU. In this paper, characteristics of the ㄷㅓ type core is studied. Detailed analyses and comparisons are given based on the sinusoidal operation and square-wave operation. Reductions in output current, voltage and power are stated analytically and numerically. The analyses are verified by experiments conducted on a ZVS converter including a detachable transformer. The analyses and comparison method can be applied to other gaped transformer such as a PCB transformer.

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Development of detachable air-cap module for improving the performance of windows (창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발)

  • Seo, Beomdong;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.

Improvement of Rod Type Mold in the Production of Freeform Concrete Panel (FCP 생산을 위한 Rod Type Mold 개선연구)

  • Palikhe, Shraddha;Lee, Donghoon;Lim, Jeeyoung;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.181-182
    • /
    • 2015
  • The production technologies of free-form concrete panels are emerging to satisfy the need of modern complex shaped in architectural design. This study aims for introducing and improvising the innovative technique called Rod type mold that overcomes the difficulties in some extent by enabling the mold to be used many times, making the shape of the mold adjustable in a flexible way and describing its production process to provide the alternative solution for the construction of free-form mold with considering the features including reusability and optimization cost across its production process. In this study, the freeform concrete panel shape was designed and experiment was done using computerized numeric control machine and rod type mold. The problems appeared on achieving desired shape while operating on rod type mold. The process of identifying all the root causes and contributing causes that may have generated an undesirable condition were done. Consequently, the conical or semicircular shaped was proposed for the end of Numerical control rod and replaced it with the existing flat shaped end to avoid the detachable problem and to improve rod type mold performance.

  • PDF

Soil Detachment by Single and Multiple Waterdrops (우적(雨滴)에 의한 토양(土壤) 침식(侵蝕))

  • Miller, W.P.;Kim, Kye-Hoon
    • Applied Biological Chemistry
    • /
    • v.38 no.2
    • /
    • pp.151-156
    • /
    • 1995
  • Single-drop splash/detachment studies and multiple-drop splash/detachment experiments were carried out to measure detachment by single and multiple drops. A raindrop tower 7.0 m in height was used to study soil splash by single drop raindrop impact over time on repacked soil samples in containers 76.2 mm in diameter. The waterdrop diameter and kinetic energy were 4.1 mm and $1.22{\times}10^{-3}$ J $drop^{-1}$, respectively. The samples consisted of five agricultural topsoils sieved to <2 mm, varying from sandy loam to clay loam in texture. The average weight of splashed soil particles after 75 drops did not show any significant difference between the five soils. The average weight of particles splashed by the first 15 drops showed that the sandy Pelham soil splashed to a greater degree than the others, and was therefore more detachable (p=0.05) than the other soils. The average weight of particles splashed by the last 15 drops also showed that the Pelham soil was the most detachable, with Cecil, Appling, Dyke, and Worsham soils being progressively less detachable. The effect of multiple drops on detachment was studied under a nozzle-type rainfall simulator at 74.9 mm $h^{-1}$ intensity for 85 min using the same soils as the single drop experiments. The total soil splash value for 85 min on Appling, Cecil, Dyke, Pelham, and Worsham soils were 6121, 6206, 4183, 5160, and 3247 g $m^{-2}$, respectively. There were no obvious relationships between soil loss measured from the different experiments.

  • PDF

A Study on the Development of Smart Athleisure Fashion Design for Night Riding (야간 라이딩을 위한 스마트 애슬레져 패션디자인 개발 연구)

  • Park, Se-Eun;Kim, Youn-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.115-122
    • /
    • 2020
  • The purpose of this study is to develop the fabric electronics-based safety protection smart athleisure fashion for night riding. Based on the characteristic analysis of products being used during night riding, the fabric LED Display and fabric type capacitive touch sensor to emphasize human friendliness were designed in detachable form through an intuitive interface to develop the smart athleisure fashion of prototype. This is meaningful in that it proposed smart Athleisure fashion products differentiated from existing products, considering the functional aspects based on fabric electronics that emphasized human friendliness and the design aspects of the customized system that can diversify design through exchange and compatibility with other Athleisure products due to detachable form. Follow-up study will focus on the improvement of textile sensor fit for the physical properties of a textile with reinforced wearability and flexibility by using Fabric Electronics and proposed customized smart fashion based on it.

Direct Carotid Cavernous Fistula of an Adult-Type Persistent Primitive Trigeminal Artery with Multiple Vascular Variations

  • Jin, Sung-Chul;Park, Hyun;Kwon, Do-Hoon;Choi, Choong-Gon
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.226-228
    • /
    • 2011
  • We report a case of spontaneous right carotid-cavernous fistula (CCF) in a proximal segment of persistent primitive trigeminal artery (PPTA) and combined vascular anomalies such as left duplicated hypoplastic proximal posterior cerebral arteries and a variation of anterior choroidal artery supplying temporal and occipital lobe. A 45-year-old male presented with progressive right exophthalmos, diplopia, and ocular pain. With manual compression of the internal carotid artery, a cerebral angiography revealed a right CCF from a PPTA. Treatment involved the placement of detachable non-fibered and fibered coils, and use of a hyperglide balloon to protect against coil herniation into the internal carotid artery. A final angiograph revealed complete occlusion of PPTA resulted in no contrast filling of CCF.

Development of a Human-Clothing-Environment Simulator for Dynamic Heat and Moisture Transfer Properties of Fabrics

  • Kim, Eun Ae;Yoo, Shinjung;Kim, Jeongjin
    • Fibers and Polymers
    • /
    • v.4 no.4
    • /
    • pp.215-221
    • /
    • 2003
  • A vertical skin model with two detachable environmental chambers was developed to simulate a Human-Clothing-Environment system and to evaluate heat and moisture transport properties of textile materials under severe conditions and during transient states. The construction of the system was described and data reproducibility and accuracy of the instrument were verified by using PEG treated nonwovens. Also advantages over a traditional static type experiment were demonstrated based on a series of experiments.

A Study for Development of Smart Taekwondo Uniform with Enhanced Functionality for Children (기능성이 향상된 아동용 스마트 태권도복 개발을 위한 연구)

  • Kim, Kyung-A
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.2
    • /
    • pp.169-181
    • /
    • 2009
  • The purpose of this study was to provide basic information for developing a smart taekwondo uniform with enhanced functionality for children by investigating the wearing condition and satisfaction of taekwondo uniform among taekwondo training children. The data were collected from 162 children living in Seoul and Daegu. For data analysis were performed descriptive statistics, ${\chi}2$ -test and t-test using SPSS Ver. 12. The results of the analysis are as follows. The results revealed that respondents wearing the general training uniform during their training period were the most. The dissatisfaction for the general training uniform was a high price, lack of symbolic, lack of functionality in textiles, lack of variety in design and unfittness of size in order. The developed uniform can adjust the length using a zipper type fastener, and can be used in all seasons as the lining is detachable. It also uses nano-silver material, and soil release finish. It enhances the functionality of movement by treating with raglan sleeve and sleeve hem velcro tape, and designs the upper garment in the draping. Safety is improved through attaching GPS, and elastic material is mixed in the neckline for putting on and off easily. Piece of cloth is added inside the closing of the upper garment. Rings are made for fixing the taekwondo uniform belt. Pocket is designed in the lower garment and colors are multiplied.

  • PDF

A study of preferences and satisfaction levels in maternity and nursing brassieres (임산부 및 수유부 전용 브래지어 실태조사와 만족도 연구)

  • Jang, Mi-Na;Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.4
    • /
    • pp.419-432
    • /
    • 2017
  • The purpose of this study was to investigate preferences and satisfaction levels in maternity and nursing brassiere. A questionnaire was conducted on 302 women from their 20s to 40s who had breastfeeding experience. The questionnaire included questions on participant demographics, purchase behavior, and design preference and satisfaction levels. The majority(98.0%) of the participants had had experience using maternity/nursing brassieres. More than 90% of the participants agreed with the need for maternity/nursing brassieres distinct from regular ones. Shopping online was the most common means of purchasing them. The most and second-most owned fastener types were the detachable shoulder belt type and inside-cup type, respectively. The most selected reason for purchasing or wearing a maternity/nursing brassiere was the convenience of donning and doffing the brassiere during breastfeeding. Participants had lower satisfaction levels with how well maternity/nursing brassieres support and center the breasts, and with the variety of designs available on the market. Respondents indicated that fasteners for breastfeeding should be developed to provide comfort and convenience for breastfeeding. Wearing comfort was reported as the most important factor in purchasing selection, both during the pregnancy and breastfeeding periods. No-wire, back closure, full-cup, U-shape wing, and skin color were the most preferred design styles.