• Title/Summary/Keyword: Desulfurization efficiency

Search Result 87, Processing Time 0.023 seconds

A Study on the Desulfurization Efficiency of Limestone Sludge with Various Admixtures

  • Seo, Sung Kwan;Chu, Yong Sik;Shim, Kwang Bo;Lee, Jong Kyu;Song, Hun
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.6
    • /
    • pp.479-482
    • /
    • 2015
  • The flue gas desulfurization (FGD) process is one of the most effective methods to reduce the amount of $SO_2$ gas (up to 90%) generated by the use of fossil fuel. Limestone is usually used as a desulfurizing agent in the wet-type FGD process; however, the limestone reserves of domestic mines have become exhausted. In this study, limestone sludge produced from the steel works process is used as a desulfurizing agent. Seven different types of additives are also used to improve the efficiency of the desulfurization process. As a result, alkaline additive is identified as the least effective additive, while certain types of organic acids show higher efficiency. It is also observed that the amount of FGD gypsum, which is a by-product of the FGD process, increases with the used of some of those additives.

Characteristics of Limestone Regeneration in the wet Limestone FGD Process (습식 석회석 배연 탈황 공정에서의 석회석 재생 특성)

  • 손종렬;문경환;모세영
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This study was performed to develop the modified FGD(Flue Gas Desulfurization) process which can eliminate the possibility of generating secondary pollutants. Limestone was regenerated by adding ammonium hydroxide and carbon dioxide, and reusing it as a absorbent in FGD gypsum Process. A series of the new or modified FGD process which include desulfurization and regeneration limestone from CaSO$_3$. 1/2H20 and CaSO4 . 2H2O, were carried out under various experimental conditions. The results showed that the optimum injection ratio for regeneration of limestone was 0.3 ml/min of CO2 flow rate, 2 ml of NH4OH per 0.01 M of regent grade CaSO4 . 2H20O and the optimum regeneration temperature was 50. The increaser was the number of times of limestone regeneration, the faster was the breakthrough point of desulfurization at the desulfurination process which the regenerated limestone was used. Then the efficiency of desulrurization was decreased. This study can be confirmed the possibility for reuse of regenerated limestone due to the similarity of desulfurization characteries both reagent grade calcium carbonate and regenerated calcium carbonate. Finally, it appeared that the new technology using regenerated 1imestone can be applied to the FGD process.

  • PDF

Enhancement of Desulfurization System Efficiency in 1,000 MW Coal-Fired Power Plants (1,000 MW 석탄화력발전소 대기환경오염물질 제거효율 향상을 위한 탈황설비 성능개선)

  • Lee, Young-Su;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.17 no.2
    • /
    • pp.32-41
    • /
    • 2021
  • Recently, air environmental issues such as fine dust have rapidly emerged as national issues, and intensive environmental regulations are being applied to coal-fired power plants. This study introduces the case of improving the performance of desulfurization facilities for removing sulfur oxides and dust, which are the main air pollutant emitters of coal-fired power plants, and conducted four case studies to improve the performance of 1,000 MW power plants currently in operation and carried out construction. Liquid ratio was increased by remodeling the absorption tower of desulfurization facilities, and vaporization reaction was promoted by increasing the flow rate of oxidized air. In addition, the gas heater leakage rate was improved to improve the efficiency of final desulfurization facilities. It is expected that performance improvement work considering harmony with existing facilities will satisfy the regulations(25ppm of sulfur oxides, 5mg/Sm3) that will be applied from 2023, and can be referred to other thermal power plants for review and application.

An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber (반건식 세정기의 산성가스 제거성능에 관한 실험적 연구)

  • Yang, Hyun-Mo;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.589-598
    • /
    • 2000
  • A pilot-scale Spray Drying Sorber (SDS) system was set up to evaluate the effect of spray characteristics on the desulfurization yield. The size distribution and the Sauter Mean Diameters of slurry droplets were measured in advance using the optical size measurement system, Malvern 2600. The desulfurization yield of the drying chamber by size was measured for the conditions of inlet gas and spray injection. As a reagent, 10% limestone slurry of $Ca(OH)_2$ was treated with flue gas containing $SO_2$, and the combustion gas analyzer and gas detectors were attached to measure the $SO_2$ concentration. With a flow rate of 144 Nm3/h and a temperature range of $200{\sim}300^{\circ}C$, the experiments were performed for the Stoichiometric Ratio (SR) of 1.0 to 3.0 and droplet mean diameter of 6.5 to $34.3{\mu}m$. In case of smaller spray droplets, the desulfurization efficiency improved due to the increase of total droplet surface area, while the reduction in evaporation time reduced the contact time between the droplets and $SO_2$ gas. In some typical region of droplet diameter, this negative effect, reduction of contact time, became dominant and the desulfurization yield decreases the desulfurization yield in spite of the expansion in absorption area. These results revealed that there exists the optimal size of spray droplets for a given state, which is determined by the compromise between the total surface area of slurry droplets and the evaporation time of droplets. The measurements also indicated that the inlet temperature of flue gas changes the optimal injection condition by varying the driving force for evaporation. The results confirm that the effect of the evaporation time of slurry droplets should be considered in analyzing the desulfurization yield as well as the total surface area, for it is a significant aspect of the correlation with the capabilities of $SO_2$ absorption in wet droplets. In conclusion, the optimal condition of spray can be determined based on these results, which might be applied to design or scale-up of SDS system.

Evaluation of SO2 Absorption Efficiency for Calcined Oyster Shell Slurry Using a Simulated Spray Type-flue Gas Desulfurization (FGD) System: A Comparative Study with Limestone Slurry (모사 Spray Type 배연탈황설비를 이용한 소성패각 슬러리의 SO2 흡수능 평가: 석회석과의 비교연구)

  • Kim, Seok-Hwi;Hong, Bum-Uh;Lee, Jin-Won;Cha, Wang-Seok;Kim, Kangjoo;Moon, Bo-Kyung
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.119-128
    • /
    • 2019
  • About 300,000 tones of oyster shell are annually produced in Korea and, thus, a massive recycling plan is required. Many desulfurizing studies using oyster shells with chemical composition of $CaCO_3$ have been performed so far; however, most of them have focused on dry desulfurization. This study investigates the possibility of using oyster shells for wet desulfurization after calcination. For this, a simulated wet desulfurization facility of spray type was devised and compared the SOx-stripping characteristics of calcined oyster shell with those of limestone. The calcined oyster shell slurry indicate a better desulfurizability than the slurries of raw shell or limestone because the oyster shell transformed to a more reactive phase ($Ca(OH)_2$) by the calcination and hydration. Because of this reason, when the calcined oyster shell slurries were used, the reaction residue showed the higher gypsum ($CaSO_4{\cdot}2H_2O$) contents than any other cases. In the continuous desulfurization experiments, calcined oyster shell slurry showed a wider pH variation than limestone or raw oyster shell slurries, another clear indication of high reactivity of calcined oyster shells for $SO_2$ absorption. Our study also shows that the efficiency of wet desulfurization can be improved by the use of calcined oyster shells.

A Study on $SO_2$Removal in Flue Gas by Semidry Flue Gas Desulfurization Method (반건식 배연탈황법에 의한 연소 페가스 중 $SO_2$제거에 관한 연구)

  • Song, Ho-Cheol;Lee, Yun-Gi;Park, Jin-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.273-280
    • /
    • 1998
  • The investigation on the removal of 502 gas fro.In flue gas which causes serious air pollution was made by using a semi dry flue gas desulfurization method. Experiments were carried out as a function of process variables which would affect SO2 removal efficiency. Process variables inclilded SO2 inlet concentration, inlet temperature of simulated flue gas, sorbent weight fraction, and volume flow rate of sorbent slurry. In this study, used sorbent was Ca(OH), and simulated flue gas was prepared by mixing pure SO2 gas with air. Experimental conditions were varied at 140~18$0^{\circ}C$ of inlet temperature of the simulated flue gas, 500~2000ppm of inlet SO2 concentration, 0.4~1.0% of sorbent concentration, and 10~25 mL/min of flow rate of sorbent slurry. Among process variables, inlet concentration of SO2 was found to be the most significant factor to affect SO2 removal efficiency. The concentration of Ca(OH2) had a lower effect on SO2 removal than SO2 inlet concentration removal amount was 0.108, 0.141, 0.153 g SO2/g Ca(OH)2 respectively- As 200 mmol of HNO3 was added into slurry to improve removal efficiency, initial pH was maintained and solubility of slurry increased, so that removal efficiency elevated. Adding over 200 mmol of HNO3 into slurry caused removal efficiency lower. Therefore it could be concluded the optimum was 200 mmol of HNO3 input.

  • PDF

A Study on Sorbent Application of Hard-Shelled Mussel Waste Shell on the Medium/small Scale Waste Incinerator and Flue Gas Desulfurization Process (중.소형 폐기물소각로 및 배연탈황공정용 홍합(Hard-Shelled Mussel) 패각페기물 Sorbent 적용에 관한 연구)

  • 정종현
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • The objective of this study is to investigate the waste recycling possibility, practicability, economic efficiency and acid gas sorbent use of the hard-shelled mussel. This study is to investigate the hydration/calcination reaction and fixed bed reactor. The physical-chemical characteristics of the hard-shelled mussel were analyzed by ICP SEM-EDX, BET and pore volume. Thus, the results could be summarized as follows; Hard-shelled mussel can be used as iron-manufacture and chemical sorbents considering more than 53.7% of the mussel is lime content. The SO$_2$removal efficiency of the hard-shelled mussel after calcined hydration increased thirty times as a result of the higher pore size, specific surface area and pore volume. Also, the CaO content, pore volume, pore size distribution and specific surface area greatly influenced the SO$_2$ and NOx removal reactivity. The optimum particle diameter average of hard-shelled mussel was $\pm$100 mesh, which was applied to the sorbent on the medium/small scale waste incinerator and flue gas desulfurization processes.

Property Analysis of Natural Brucite and Its Application as Sulfur Dioxide Absorbent (천연 Brucite의 물성분석 및 이산화황 흡수제로의 응용)

  • Kang, Seong-Gu;Kim, Myoung-Hwan;Kim, Jin-Bae
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.239-244
    • /
    • 2009
  • $Mg(OH)_2$ slurry was prepared by using natural mineral brucite mined in Liaoning province in China, and its de-$SO_x$ efficiency was compared with that of $Mg(OH)_2$ slurry prepared by thermal decomposition and hydration of magnesite. The physical and chemical characteristics of $Mg(OH)_2$ Powders prepared from brucite and magnesite were similar. However, the layered plate structure of $Mg(OH)_2$ crystal particles prepared from brucite had grown more stably. The desulfurization efficiency of $Mg(OH)_2$ slurry prepared from brucite was slightly higher than that of magnesite. Brucite may be used as a new absorbent for the desulfurization of flue gas in the future.

Desulfurization Efficiency of Lime Absorbent in In-Furnace Desulfurization as Fly Ash Binder in Power Plant (발전소 비산재를 결합재로 활용한 로내탈황용 석회 흡수제의 탈황효율)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Cho, Jin-Sang;Ahn, Ji-Whan;Yoon, Do-Young;Cho, Kye-Hong
    • Resources Recycling
    • /
    • v.27 no.3
    • /
    • pp.58-65
    • /
    • 2018
  • For the recycling of coal ash from the domestic circulating fluidized bed boilers, a lime-based sorbent with 0.2~0.4 mm size was prepared by using limestone powder and CFBC fly ash. Mixing a small amount of slaked lime in the lime-based absorbent lead the formation of calcium silicate on the surface of the particle and the strength of absorbent particle was improved. As a result of comparing the desulfurization characteristics, it was found that the conversion rate was about 10% higher than that of commercially available limestone desulfurization used in the furnace, which is confirmed that it can be used as a desulfurization absorbent.

The Effect of Spray Characteristics on Flue Gas Desulfurization Yield in Spray Drying Sorber (반건식 세정기의 슬러리 분무 특성에 따른 산성가스 제거효율)

  • Yang, Hyun-Mo;Kim, Sang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.79-84
    • /
    • 2001
  • The effect of spray characteristics on desulfurization yield was evaluated by performing experiments with pilot spray drying sorber (SDS). Among the variables of operating conditions, the slurry-spraying conditions were chosen as major parameters; Stoichiometric ratio and Sauter mean diameter of slurry droplet were varied for the different gas temperatures and $SO_{2}$ concentrations in the inlet gas flow. From the experimental results, we proposed semi-empirical models of desulfurization yield for both Stoichiometric ratio and Sauter mean diameter of droplets. The optimal condition of spray can be determined based on these results, which might be applied to the design or scale-up of SDS systems.