Abstract
Recently, air environmental issues such as fine dust have rapidly emerged as national issues, and intensive environmental regulations are being applied to coal-fired power plants. This study introduces the case of improving the performance of desulfurization facilities for removing sulfur oxides and dust, which are the main air pollutant emitters of coal-fired power plants, and conducted four case studies to improve the performance of 1,000 MW power plants currently in operation and carried out construction. Liquid ratio was increased by remodeling the absorption tower of desulfurization facilities, and vaporization reaction was promoted by increasing the flow rate of oxidized air. In addition, the gas heater leakage rate was improved to improve the efficiency of final desulfurization facilities. It is expected that performance improvement work considering harmony with existing facilities will satisfy the regulations(25ppm of sulfur oxides, 5mg/Sm3) that will be applied from 2023, and can be referred to other thermal power plants for review and application.
Keywords
Power Plant; Process Design; Desulfurization System; Performance Improvement; Absorber;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Doosan Heavy Industries & Construction Co., 2017 "Technical Proposal for the Performance Improvement of SinBoryeong Thermal Power Dehydrogenation Facilities."
2 Chungcheongnam-do, 2019 "Ordinance on Standards for Allowance of Air Pollutants in Chungcheongnam-do".
3 Choi Hyun-ho, 2018, "appropriate pH for desulfurization facilities of 200 MW anthracite power plants," Hanyang University's master's degree thesis, p. 20.
4 Binlin Doubt, 2009, "Prediction of SO2 Removal Efficiency for We Flue Gas Desulfurization".
5 Korea Institute of Development Education, 2016, "Working on Desulfurization Facilities," 2016 Development Bridge-Revision-3 Textbook.
6 KEPCO E&C, 2017, "Review on the improvement of atmospheric environmental facilities' performance by strengthening standards for allowing air pollutant emissions," pp. 9-10.
7 Korea Midland Power Co., 2017. "Shin Boryeong Air Environment Facility Performance Improvement Plan," Construction Office.
8 Korea Midland Power Co., 2019, "Report on the Second Performance Test Results of Shin Boryeong Unit 2 Back-to-Fluoride Evacuation Facility," Turbine Technology Department.
9 Korea Electric Power Corp., 2017, "Operation Manipulation Manual", pp. 15-5, 15-28, 15-29.
10 Park Seung-soo, Ahn Hee-soo, 2011, "How and its devices improve desulfurization rates in the smoke desulfurization process," the Korean Intellectual Property Office, pp. 3-4.
11 Zhen et al, 2018, "Experimental study on the synthetic restoration of fine particles by we flow gas desulfurization tower with a flow pattern control device."
12 Sung Ki-jong, Lee Chang-sik, 2017, "Operation and Improvement of Non-leakage Type GasGas Heater(GGH) forCoal-fired Dehydrogenation Facilities," Korean Combustion Society, p. 37.
13 SRI EPA Report, 2006, "Estimized SO3 Removal Efficiency," Table 2-4.
14 Kim Jong-sung, 2018, "Performance Improvement of 500 MW Coal-fired Power Plant desulfurization Facilities with Structural Constraints," Hanyang University Master's Degree Paper, p. 18, pp. 23-25.