DOI QR코드

DOI QR Code

An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber

반건식 세정기의 산성가스 제거성능에 관한 실험적 연구

  • 양현모 (한국과학기술원 대학원 기계공학과) ;
  • 김상수 (한국과학기술원 기계공학과)
  • Published : 2000.04.01

Abstract

A pilot-scale Spray Drying Sorber (SDS) system was set up to evaluate the effect of spray characteristics on the desulfurization yield. The size distribution and the Sauter Mean Diameters of slurry droplets were measured in advance using the optical size measurement system, Malvern 2600. The desulfurization yield of the drying chamber by size was measured for the conditions of inlet gas and spray injection. As a reagent, 10% limestone slurry of $Ca(OH)_2$ was treated with flue gas containing $SO_2$, and the combustion gas analyzer and gas detectors were attached to measure the $SO_2$ concentration. With a flow rate of 144 Nm3/h and a temperature range of $200{\sim}300^{\circ}C$, the experiments were performed for the Stoichiometric Ratio (SR) of 1.0 to 3.0 and droplet mean diameter of 6.5 to $34.3{\mu}m$. In case of smaller spray droplets, the desulfurization efficiency improved due to the increase of total droplet surface area, while the reduction in evaporation time reduced the contact time between the droplets and $SO_2$ gas. In some typical region of droplet diameter, this negative effect, reduction of contact time, became dominant and the desulfurization yield decreases the desulfurization yield in spite of the expansion in absorption area. These results revealed that there exists the optimal size of spray droplets for a given state, which is determined by the compromise between the total surface area of slurry droplets and the evaporation time of droplets. The measurements also indicated that the inlet temperature of flue gas changes the optimal injection condition by varying the driving force for evaporation. The results confirm that the effect of the evaporation time of slurry droplets should be considered in analyzing the desulfurization yield as well as the total surface area, for it is a significant aspect of the correlation with the capabilities of $SO_2$ absorption in wet droplets. In conclusion, the optimal condition of spray can be determined based on these results, which might be applied to design or scale-up of SDS system.

Keywords

References

  1. Miller, M. J., 1986, Retrofit $SO_2$ and $NO_x$ Control Technologies for Coal-Fired Power Plants,' Environ. Prog., Vol. 5, No.3, p. 171-177 https://doi.org/10.1002/ep.670050311
  2. Keener, T. C., and Keener, S. U., 1986, 'Current Status of Flue Gas Desulfurization in the United States,' Presented at the ASCE Environmental Engineering Division National Conference
  3. Peterson, Tom and Karlsson, Hans T., 1988, 'The Significance of Fly Ash in Wet-Dry Scrubbing of $SO_2$' Chem. Eng. Technol., Vol. 11, p. 298-305 https://doi.org/10.1002/ceat.270110139
  4. Martinez, C. J., Izquierdo, F. J., Cunill, E, Tejero, J., and Querol, J., 1991, 'Reactivation of Fly Ash and $Ca(OH)_2$ Mixtures for $SO_2$ Removal of Flue Gas,' Ind. Eng. Chem. Res, Vol. 30, p. 2143-2147 https://doi.org/10.1021/ie00057a013
  5. Jorgensen, C., Chang, J. C. S., and Brna, T. G., 1987, 'Evaluation of Sorbents and Additives for Dry $SO_2$ Removal,' Environ. Prog., Vol. 6, No.1, p. 26-32 https://doi.org/10.1002/ep.670060120
  6. Ho, C. H. and Shih, S. M., 1992, '$Ca(OH)_2$/lFly Ash Srobents for $SO_2$ Removal,' Ind. Eng. Chem. Res., Vol. 31, No.4,p.1120-1135 https://doi.org/10.1021/ie00004a023
  7. Sanders, John E, Keener, Tim C., and Wang Jun., 1995, 'Heated Fly AshlHydrated Lime Slurries for $SO_2$ Removal in Spray Dryer Absorbers,' Ind. Eng. Chem. Res., Vol. 34, p. 302-307 https://doi.org/10.1021/ie00040a032
  8. Ollero, P., Salvador, L., and Canadas, L., 1997, 'An Experimental Study of Flue Gas Desulfurization in a Pilot Spray Dryer,' Environ. Prog., Vol. 16, No.1, p. 20-28 https://doi.org/10.1002/ep.3300160116
  9. Brogren, C. and Karlsson, H. T., 1997, 'Modeling the Absorption of $SO_2$ in a Spray Scrubber Using the Penetration Theory,' Chem. Eng. Sci., Vol. 52, No. 18, p. 3085-3099 https://doi.org/10.1016/S0009-2509(97)00126-7
  10. Kieviet, F. G., and Kerkhof, P. J. A. M., 1997, 'Air Flow, Temperature and Humidity Patterns in a Cocurrent Spray Dryer: Modeling and Measurements,' Drying Technology, Vol. 15, No. 6-8, p. 1763-1773 https://doi.org/10.1080/07373939708917325
  11. Masters, K., 1985, 'Spray Drying Handbook,' 4th ed., Pitman Press, London
  12. Yang, H. M. and Kim, S. S., 1997, 'Modeling Behaviors of Gas and Droplets in Spray Dryer,' presented at the 16th Annual Conference of the American Association for Aerosol Research, 5PM6, p.142
  13. Yang, H. M. and Kim, S. S., 1999, 'Modeling Desulfurization Performance of Spray Drying Sober using CFD,' presented at the 18th Annual Conference of the American Association for Aerosol Research
  14. Maurin, P. G., and Peters, M. J., 1983, 'Two-Fluid Nozzle vs. Rotary Atomization for Dry-Scrubbing Systems,' CEP, p. 51-59
  15. Son, S. Y. and Kihm, K. D., 1998, 'Effect of Coal Particle Size on Coal- Water Slurry (CWS) Atomization,' Atomization and Sprays, Vol. 8, p. 503-519