• Title/Summary/Keyword: Design-time history

Search Result 952, Processing Time 0.026 seconds

Design and Implementation of Space Time Point for Real-time Public Transportation Route Guidance (실시간 대중교통 경로안내를 위한 Space Time Point 모델의 설계와 구현)

  • Kim, Soo-Ho;Joo, Yong-Jin;Park, Soo-Hong
    • Spatial Information Research
    • /
    • v.20 no.3
    • /
    • pp.83-93
    • /
    • 2012
  • Recent environmental concerns have made interest in environment-friendly transportation means such as walking, biking, and public transportation. However, since it is difficult to move long distance by walking or biking, their scope of application is rather limited. On the other hand, public transportation can solve traffic congestion, a recent social issue, though its usability may depend on its time schedule. Currently available information services on public transportation in the Web do not reflect well such traits of the public transportation; thus, in some cases, they may provide wrong information to end users. To solve such problems and provide information based on timetable of public transportations, this paper proposes a STP(Space Time Point) data model. Unlike existing space-time data models, this model recognizes the bottommost element of an object as a point and structures these points in hierarchical way to define an object. In particular, It can make it possible to implement a variety of dynamic spatial objects changing object information according to time. An objective of this study is to design a STP model for bus and subway based on timetables of public transportation in Daejeon area and builds a system to provide path navigation. With the designed navigation function, a path from the Daejeon National Cemetery to Hannam University was searched by time slot. The result showed that the system provided different paths by time, as the system guided different paths when bus operation was limited in midnight. As existing data model could not provide such results, it is confirmed that the system can provide path navigation based on real-time traffic information. It is expected that based on such functionality, it is possible to provide additional functionalities by applying diverse data models such as real-time transport information or traffic history information.

A Study on the Restoration of the Wangheungsa Temple's Wooden Pagoda (왕흥사 목탑의 복원 연구)

  • Kim, Kyeong-Pyo;Sung, Sang-Mo
    • Journal of architectural history
    • /
    • v.19 no.3
    • /
    • pp.7-29
    • /
    • 2010
  • The form of the Wangheungsa Temple's wooden pagoda site is that of the traditional form of the wooden pagodas constructed during the Baekjae Period. Likewise, it is an important ruin for conducting research on the form and type of the wooden pagodas constructed during the Baekjae Period. In particular, the method used for the installation of the central pillar's cornerstone is a new technique. The purpose of this research is to restore the ruin of the Wangheungsa Temple's wooden pagoda of the Baekjae Period that remains at the Wangheungsa Temple's wooden pagoda site. Until now, research conducted on the wooden pagoda took place mostly centered on the Hwangryongsa Temple's wooden pagoda. Meanwhile, the reality concerning Baekjae's wooden pagoda is one in which there were not many parallel cases pertain to the design for restoration. This research paper wants to conduct academic examination of the Wangheungsa Temple's wooden pagoda to organize the intention of design and design process in a simple manner. This research included review of the Baekjae Period's wooden pagoda related ruins and the review of the existing wooden pagoda ruin to analyze the wooden pagoda construction technique of the era. Then, current status of the Wangheungsa Temple's wooden pagoda site is identified to define the characteristics of the wooden pagoda, and to set up the layout format and the measure to estimate the size of the wooden pagoda in order to design each part. Ultimately, techniques and formats used for the restoration of the wooden pagoda were aligned with the wooden pagoda of the Baekjae Period. Basically, conditions that can be traced from the current status of the Wangheungsa Temple site excavation using the primary standards as the standard. Wangheungsa Temple's wooden pagoda was designed into the wooden pagoda of the Baekjae's prosperity phase. The plane was formed into $3{\times}3$ compartments to design into three tier pagoda. The height was decided by factoring in the distance between the East-West corridors, size of the compartment in the middle, and the view that is visible from above the terrace when entering into the waterway. Basically, the origin of the wooden structure format is based on the Goguryeo style, but also the linkage with China's southern regional styles and Japan's ancient wooden pagoda methods was factored in. As for the format of the central pillar, it looks as if the column that was erected after digging the ground was used when setting up the columns in the beginning. During the actual construction work of the wooden pagoda, central pillar looks as if it was erected by setting up the cornerstone on the ground. The reason that the reclaimed part of pillar that use the underground central cornerstone as the support was not utilized, was because the Eccentric Load of the central pillar's cornerstone was factored in the state of the layers of soil piled up one layer at a time that is repeated with the yellow clay and sandy clay and the yellow clay that were formed separately with the $80cm{\times}80cm$ angle at the upper part of the central pillar's cornerstone was factored in as well. Thus, it was presumed that the central pillar was erected in the actual design using the ground style format. It is possible to presume the cases in which the reclaimed part of pillar were used when constructed for the first time, but in which central pillar was installed later on, after the supplementary materials of the underground column is corroded. In this case, however, technique in which soil is piled up one layer at a time to lay down the foundation of a building structure cannot be the method used in that period, and the reclamation cannot fill up using the $80cm{\times}80cm$ angle. Thus, it was presumed that the layers of soil for building structure's foundation was solidified properly on top of the central pillar's cornerstone when the first wooden pagoda construction work was taking place, and that the ground style central pillar was erected on its upper part by placing the cornerstone once again. Wangheungsa Temple's wooden pagoda is significant from the structure development aspect of the Korean wooden pagodas along with the Hwangryongsa Temple's wooden pagoda. Wangheungsa Temple's wooden pagoda construction technique which was developed during the prosperity phase of the Baekjae Period is presumed to have served as a role model for the construction of the Iksan Mireuksa Temple's wooden pagoda and Hwangryongsa Temple's wooden pagoda. With the plan to complement the work further by excavating more, the basic wooden pagoda model was set up for this research. Wangheungsa Temple's wooden pagoda was constructed as at the Baekjae Kingdom wide initiative, and it was the starting point for the construction of superb pagoda using state of the art construction techniques of the era during the Baekjae's prosperous years, amidst the utmost interest of all the Baekjae populace. Starting out from its inherent nature of enshrining Sakyamuni's ashes, it served as the model that represented the unity of all the Baekjae populace and the spirit of the Baekjae people. It interpreted these in the most mature manner on the Korean peninsula at the time.

Improved Distribution of Lateral Seismic Forces for Evaluation of Inelastic Seismic Response of RC Irregular Building Structures (비정형 RC 건축구조물의 비선형 지진응답 평가를 위한 개선된 횡하중 분배 방법)

  • 최원호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.322-329
    • /
    • 2000
  • Current seismic design codes for building structures are based on the methods which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. Pushover analysis of fast becoming an accepted method for the seismic evaluation of building structures. The popularity of this approximate, nonlinear static analysis method is due to its conceptual simplicity and ability to graphically describe a capacity and demand of structure. However, some of the shortcomings of the pushover analysis, especially for longer period and irregular buildings, is the inability of method to identify failure mechanisms due to effects of higher modes. In this paper proposed lateral load pattern which includes the contribution of higher modes of vibration for irregular building structure and compared to seismic response obtained by time history.

  • PDF

Dynamic Analysis of Guyed Tower Subjected to Wave Forces (파랑하중에 대한 Guyed Tower의 동적해석)

  • Ryu, Jung Sun;Yun, Chung Bang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.87-94
    • /
    • 1985
  • Dynamic analysis of guyed tower is presented in this paper. The scope of the study is twofold. The one is to determine an efficient analysis method to include the nonlinearity of the mooring system and the nonlinear hydrodynamic wave forces. The other is to investigate the sensitivity of two major design parameters, that is the stiffness of mooring system and the fixity condition of the tower at mud line. Time history analysis method utilizing mode superposition is mainly considered. However several other methods are also used for the purpose of comparison. Analyses are carried out using the Lena Guyed Tower, which is the first structure of this kind, as a standard structure.

  • PDF

Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant (원자력발전소 보호시스템 캐비넷의 내진검증)

  • 정명조;황원걸
    • Computational Structural Engineering
    • /
    • v.6 no.2
    • /
    • pp.79-86
    • /
    • 1993
  • A method to verify seismic qualification of the plant protection system cabinet for a nuclear power plant is presented. A finite element model of the cabinet is developed and the dynamic characteristics are obtained. The results of the modal analysis provide insight into the fundamental dynamic properties of the structure, which correspond to the frequency of the peak values of the input seismic spectrum. It necessitates the design modification of the reference cabinet. Techniques for verifying structural integrity and operability are exemplified by summarizing response spectrum and time history analyses of the structure.

  • PDF

Seismic Margin Analysis of Reinforced Concrete Pier Using Damage Model Proceedings (손상모형을 이용한 철근 콘크리트 교각의 지진여유도 해석)

  • 고현무;이지호;정우영;조호현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.220-227
    • /
    • 2002
  • This study introduces the fragility analysis method for the safety evaluation of reinforced concrete pier subject to earthquake. Damage probability is calculated instead of the failure probability from definition of the damage state in the fragility curve. Not only the damage model determined by the response of structure subject to earthquake, but also the plastic-damage model which can represent the local damage is applied to fragility analysis. The evaluation method of damage state by damage variable in global structure is defined by this procedure. This study introduces the fragility analysis method considering the features of nonlinear time history behavior of reinforced concrete element and the plastic behavior of materials. At last, This study gives one of the approach method for seismic margin evaluation with the result of fragility analysis to design seismic load.

  • PDF

A Comparison Study on Accredited Architectural Education Contents between US and Korea

  • Kim, Jin-Wook
    • Architectural research
    • /
    • v.13 no.2
    • /
    • pp.13-21
    • /
    • 2011
  • Since 2002, Architecture Schools in Korea was changing long traditional architectural education system from 4 years generalized architectural engineering curriculum to 5 years professional architecture program. Until 2010, 76 architecture schools have changed their program to 5 years course which was focused to design studio education. It was a very rapid change and there was not much time develop their own system which could represent institutional identity, character of students and local environment. Korea joined as a regular member of Canberra Accord in 2010 and it is meaningful to compare Korean architecture program contents to another country education contents. US architecture programs were selected for this comparison study. The goals of this study are to create a comparable understanding the form of contents of Architectural Education in US and Korea and to verify the substantial equivalence of these systems. To achieve above goals, three public institutes of each country were selected and analyzed with general information, history, resources, curriculum and the matrix of Student Performance Criteria for quantitative comparison. For qualitative comparison education context of programs were analyzed with program missions, the way of advising, professional connection and distribution of faculty loads.

A Comparison of Time History Analysis to UBC-88 Requirements in a Low Seismic Zone (약진지역에 있어서의 시간이력 해석과 UBC 규준 해석의 비교)

  • 김희철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.10a
    • /
    • pp.90-95
    • /
    • 1991
  • The Uniform Building Code (UBC) is the most widely used requirements for earthquake resistant design in the United States. In this paper, a mid-rise steel building is analyzed by applying 12 sets of actual strong-motion earthquake data that have been scaled to acne 2B levels. The simply extrapolated ground motion displacements are used for the dynamic loads. The results of dynamic analyses for a 10-story steel building are compared with the static and dynamic analysis requirements of UBC-88. It was found that computed lateral fortes using UBC-88 static procedure differed by about 60 percent depending on whether the natural period was computed using the UBC empirical method or the UBC recommended Rayleigh's method. The lateral fortes computed from the UBC response spectra were more than 10 times greater than those computed by UBC static procedures. The lateral forces obtained from both linear and nonlinear analyses using 1989 Loma Prieta ground mot ions compared very well with UBC response spectra results.

  • PDF

원자력發電所의 耐震設計용 入力 地震의 決定

  • 서정희
    • Journal of the KSME
    • /
    • v.20 no.5
    • /
    • pp.387-391
    • /
    • 1980
  • 일반적으로 내진 설계라 함은 지진에 의하여 발생된 지진동이 특정한 구조물에 작용할 때 이 지 진동의 경향하에서도 구조물의 정상적인 기능을 추진할 수 있도록 설계하는 것을 말하는 바, 원자력발전소의 내진설계에 있어서도 원칙적으로는 동일한 개념이나 실시하는 규정이 타구조물에 비하여 훨씬 엄격한 것이 다른 점이라 하겠다. 현재 우리나라의 경우 원자력 발전소는 1기(고리 #1)가 가동중이고 2기(월성 #1, 고리 #2)가 거의 완공단계에 있으며 7기(고리 #3, #4, 월성 #2, 계마 #1, #2, 부구 #1, #2)가 건설작업중인 바 이중 부구의 경우만 프랑스(\ulcorner)에서 건설 예정이고 기타는 모두 미국 및 카나다에서 건설하였거나 건설 예정이므로 따라서 그 설계에 있어서도 제 규정은 대체로 미국것을 준용하고 있는 형편이다. 그러므로 본고에서 는 미국에서 시행되고 있는 방법 또는 규정에 의거하여 내진설계용 입력지진에 대하여 설명하고자 한다. 내진설계에 입력 으로 사용되는 지진을 설계기준지진(design basis earthquake, DBE)이라고 통칭하며 이 지진은 미국 규정에 의하면 응답스펙트럼(response spectrum)으로 정의되게 되어 있으며 또한 이 응답 스펙트럼에 준하는 인공정인 지진의 시간기득(artificial time history)을 작성 또는 선정하여 이를 발전소 구조물의 내진 해석 및 내진 시험 입력으로 사용하게 되어 있다.

  • PDF

Seismic performance of reinforced concrete shear wall buildings with underground stories

  • Saad, George;Najjar, Shadi;Saddik, Freddy
    • Earthquakes and Structures
    • /
    • v.10 no.4
    • /
    • pp.965-988
    • /
    • 2016
  • This paper investigates the seismic behavior of reinforced concrete shear wall buildings with multiple underground stories. A base-case where the buildings are modeled with a fixed condition at ground level is adopted, and then the number of basements is incrementally increased to evaluate changes in performance. Two subsurface site conditions, corresponding to very dense sands and medium dense sands, are used for the analysis. In addition, three ground shaking levels are used in the study. Results of the study indicated that while the common design practice of cropping the structure at the ground surface leads to conservative estimation of the base shear for taller and less rigid structures; it results in unpredicted and nonconservative trends for shorter and stiffer structures.