• Title/Summary/Keyword: Design Allowable

Search Result 914, Processing Time 0.029 seconds

A Study on Designing an Effective Support Point for After-Stern Tube Bearings Concerning Shaft Alignment (추진축계 정렬시 선미관 베어링 유효지지점 설정에 관한 연구)

  • Lee, Jae-ung;Kim, Yeonwon;Kim, Jung-Ryul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.803-809
    • /
    • 2018
  • Generally, the gap-and-sag method is used in the shipbuilding stage before coupling the shafts to check whether they are installed at the same position as designed and derived from shaft alignment calculation. The primary installed propeller shaft becomes a reference point, the position of the remaining shafts are sequentially determined through the gap-and-sag value derived from the deflection and deflection angle at each shaft flange by own weight. If the reference point varies against the design value, it would have a series of effects on the installation of the remaining shafts. Moreover, after coupling the shafts, even if the bearing reaction forces derived from measurement are satisfied by the allowable limit range, consequently it might have an adverse effect on the stability of the shafting system by not being able to estimate the relative slope angle between the propeller shaft and the after-stern tube bearing. In this paper, to deal with above-mentioned phenomenon, the theoretical calculations related to designing an effective support point of the aft stern tube bearing and analysis by measurement is conducted through a case of open-up inspections. Based on this, a shaft installation guideline is proposed to minimize the misalignment related to preventing wiping damage of the after-stern tube bearing.

RRP Loading Patterns and Standard Dimensions for Block Pattern in Membership Wholesale Clubs (Membership Wholesale Club에서의 RRP 적재패턴 및 블록패턴 표준규격에 관한 연구)

  • Jung, Sung-Tae;Han, Kyu-Chul
    • Journal of Distribution Science
    • /
    • v.13 no.7
    • /
    • pp.41-51
    • /
    • 2015
  • Purpose - This study analyzes loading efficiency by loading pattern for package standardization and reduction of logistics costs, along with the creation of revenue for the revenue review panel (RRP) of Membership Wholesale Clubs (MWC). The study aims to identify standard dimensions that can help improve the compatibility of the pallets related to display patterns preferred by the MWC and thereby explore ways to enhance logistics efficiency between manufacturers and retailers through standardization. Research design, data, and methodology - The study investigates and analyzes the current status based on actual case examples, i.e., manufacturer A and Korea's MWC (A company, B company, and C company), and thus devises improvement measures. To achieve this, the case of manufacturer A delivering to MWC was examined, and the actual pallet display patterns for each MWC were investigated by visiting each distribution site. In this study, TOPS (Total Optimization Packaging Software, USA) was used as the tool for pallet loading efficiency simulations the maximum allowable dimension was set to 0.0mm to prevent the pallet from falling outside the parameters, and the loading efficiency was analyzed with the pallet area. In other words, the study focused on dimensions (length x width x height) according to the research purpose and thereby deduced results. Results - The analysis of pallet loading patterns showed that the most preferred loading patterns for loading efficiency according to product specification, such as pinwheel, brick, and block patterns, were used in the case of the general distribution products, but the products were configured with block patterns in most cases when delivered to MWCs. The loading efficiency by loading pattern was analyzed with respect to 104 nationally listed standard dimensions. Meanwhile, No.51 (330 × 220mm) of KS T 1002 (1,100 × 1,100mm) was found to be the dimension that could bring about an improved loading efficiency, over 90.0% simultaneously in both the T-11 and T-12 pallet systems in a loading pattern configuration with the block pattern only, and the loading efficiency simulation results also confirmed this as the standard dimension that can be commonly applied to both the T-11 pallet (90.0%) and the T-12 pallet (90.7%) systems. Conclusions - The loading efficiency simulation results by loading pattern were analyzed: For the T-11 pallet system, 17 standard dimension sizes displayed the loading efficiency of 90.0% or more as block patterns, and the loading capacity was an average of 99.0%. For the T-12 pallet system, 35 standard dimension sizes displayed the loading efficiency of more than 90% as block patterns (the average loading efficiency of 98.6%). Accordingly, this study proposes that the standard dimensions of 17 sizes with the average loading efficiency of 99.0% should be applied in the use of the T-11 pallet system, and those of 35 sizes with the average loading efficiency of 98.6% should be reviewed and applied in the use of the T-12 pallet system.

A Study on Static and Fatigue Behavior of Restrained Concrete Decks without Rebar by Steel Strap (Steel Strap으로 횡구속된 무철근 바닥판의 정적 및 피로거동 특성 연구)

  • Jo, Byung Wan;Kim, Cheol Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.137-147
    • /
    • 2012
  • In the steel-free bridge concrete deck, steel straps are generally used instead of conventional steel rebar while laterally restrained in the perpendicular direction to the traffic in order fir the arching effect of concrete deck. In this paper, the minimum amount of FRP bar is to be suggested based on the structural strength, crack propagation, stress level and others in order to control cracks. As a result of laboratory tests, the structural strength of deck with 0.15 percentage of steel strap showed improved structural strength including ductility. The long-term serviceability of steel strap deck with FRP bar proved to satisfy the requirements and to be structurally stable while showing the amount of crack and residual vertical displacement within the allowable limits after two million cyclic loadings. The structural failure of RC bridge deck is generally caused from the punching shear rather than moment. Therefore, the ultimate load at failure could be estimated using the shear strength formula in the two-way slab based on ACI and AASHTO criteria. However the design criteria tend to underestimate the shear strength since they don't consider the arching effects and nonlinear fracture in bridge deck with lateral confinement. In this paper, an equation to estimate the punching shear strength of steel strap deck is to be developed considering the actual failure geometries and effect of lateral confinement by strap while the results are verified in accordance with laboratory tests.

Analysis of Piled Raft Bearing Capacity Increase with Centrifuge Test (원심모형시험을 통한 Piled Raft 기초의 지지력증가 특성 분석)

  • Park, Dong-Gyu;Choi, Kyu-Jin;Kim, Dong-Wook;Chung, Moon-Kyung;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.8
    • /
    • pp.43-53
    • /
    • 2012
  • In the conventional design of a piled raft, the axial resistance offered by the raft itself is typically neglected and only that of the group pile is accounted in estimating the total axial resistance of the piled raft. As a consequence, piled rafts are usually designed conservatively by neglecting the raft resistance. In this study, a series of centrifuge model tests have been performed to compare the axial behavior of a group pile with that of a piled raft (both having 16 component piles with an array of $4{\times}4$) in sands with different relative densities and in clays with different preconsolidated pressures. The test results revealed that, with respect to the allowable settlement of 25 millimeters for bridge foundations, the piled raft resistances were greater than those of the group pile by 13% for dense sand, by 22% for loose sand, by 30% for stiff clay, and by 22% for soft clay. Furthermore, the ratio of piled raft resistance to group pile resistance increased as the settlement increased.

Performance Comparison of Taylor Series Approximation and CORDIC Algorithm for an Open-Loop Polar Transmitter (Open-Loop Polar Transmitter에 적용 가능한 테일러 급수 근사식과 CORDIC 기법 성능 비교 및 평가)

  • Kim, Sun-Ho;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.9
    • /
    • pp.1-8
    • /
    • 2010
  • A digital phase wrapping modulation (DPM) open-loop polar transmitter can be efficiently applied to a wideband orthogonal frequency division multiplexing (OFDM) communication system by converting in-phase and quadrature signals to envelope and phase signals and then employing the signal mapping process. This mapping process is very similar to quantization in a general communication system, and when taking into account the error that appears during mapping process, one can replace the coordinates rotation digital computer (CORDIC) algorithm in the coordinate conversion part with the Taylor series approximation method. In this paper, we investigate the application of the Taylor series approximation to the cartesian to polar coordinate conversion part of a DPM polar transmitter for wideband OFDM systems. The conventional approach relies on the CORDIC algorithm. To achieve efficient application, we perform computer simulation to measure mean square error (MSE) of the both approaches and find the minimum approximation order for the Taylor series approximation compatible to allowable error of the CORDIC algorithm in terms of hardware design. Furthermore, comparing the processing speeds of the both approaches in the implementation with FPGA reveals that the Taylor series approximation with lower order improves the processing speed in the coordinate conversion part.

Load Transfer Mechanism of Drilled Shafts in Weathered Rock (풍화된 암반에 근입된 현장타설말뚝의 하중전이기구)

  • ;Cho Sung-Min;Jung Sung-Jun;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.187-196
    • /
    • 2005
  • Since the allowable bearing capacities of piles in weathered/fractured rock are mainly governed by settlement, the load-displacement behavior of pile should be known accurately. To predict pile head settlement at the design stage, the exact understanding of the load-transfer mechanisms is essential. Therefore, in this research, the load-transfer mechanism of drilled shaft socketed into weathered rock was investigated. For the investigation, five cast-in-place concrete piles with diameters of 1,000 mm were socketed into weathered gneiss. The static axial load tests and the load-transfer measurements were performed to examine the axial resistant behavior of the piles. A comprehensive field/laboratory testing program on weathered rock at the Held test sites was also performed to describe the in situ rock mass conditions quantitatively. And then, the effect of rock mass condition on the load transfer mechanism was investigated. The f-w (side shear resistance-displacement) curve of the pile in moderately weathered rock reached to yielding point at a for millimeter displacements, and after yielding point, the rate of resistance increment dramatically decreased. However, the f-w curve in the highly/completely weathered rock did not show the obvious yielding point, and the resistance gradually increased showing the hyperbolic pattern until relatively high displacement (>15 mm). The q-w (end bearing resistance-displacement) curves showed linear response at least until the base displacement of approximately 10 mm, regardless of rock mass conditions.

Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors (공압 실린더 액츄에이터 위치제어)

  • Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won;Park, Jong-Min;Kwon, Soon-Goo;So, Jung-Duk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.

A Fundamental Study on the Fatigue Behavior in the Joints of Steel Members (강부재(鋼部材) 이음부(部)의 피로거동(疲勞擧動)에 관(關)한 기초적(基礎的) 연구(硏究))

  • Lee, Yong Jae;Chung, Yeong Wha
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.21-28
    • /
    • 1989
  • For the study of the fatigue behavior, high-strength bolted connections on a small scale were manufactured, and carried on fatigue tests. Its experimental values were analysed by stress-fatigue life (S-N) curve. Three types of specimens : the base metal, the cireular hole and the welded sperimens had same net section were made. Through the same tests those experimental values were compared with those of the high-strength bolted conneetions. The results of these studies are as followings. It was found that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the high-strength bolted conneetions were much more about 14% and 16% than that of the base metal specimen. It was thought that this trend was due to frictional force increasing fatigue strength. It was known that fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the welded joints were less 29% and 21% than that of base metal specimen. It was thought that that trend was due to weld flaw. It was appeared that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the high-strength bolted connections were much more about 38% and 30% than that of welded joint. It was thought that it was due to both frictional force increasing the fatigue strength in bolted connections and weld flaw decreasing the fatigue strength in welded connections. It was found that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the B3 specimens were much more 2% and -2% than that of the B4 specimen. It was thought that that trend was due to the frictional force, which concerned with shape of specimen. It was known that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the specimen with circular hole was less 61% and 65% than that of base metal. It was known that the allowable stress for bolted joint was higher than that of welded Joints. If that research is continued and more data are accumulated it can be expected that a basic pattern to provided the indicator of the fatigue design of the bolted connections of steel structures and persume the safety and lifeproof of existing structures is given.

  • PDF

Seismic Performance of Reinforced Concrete Shear Wall Buildings with Piloti (필로티를 갖는 철근콘크리트 전단벽식 건물의 내진성능)

  • Kwon Young-Wung;Kim Min-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.587-594
    • /
    • 2005
  • The purpose of seismic design is to ensure the serviceability of buildings against earthquake, which might be occurred during the service life of buildings, and to minimize the loss of life by preventing their failure under strong earthquake. The lack resistance of walls resulting from a tendency toward high-rise apartment buildings with shear walls and use of piloti would lead to a concentration of inelastic behaviors in their weak story. In this study, the seismic performance of reinforced concrete shear wall buildings haying piloti was analyzed by using the evaluation techniques which was proposed by FEMA 273 and ATC-40. The results from comparison with these two techniques are summarized as follows.; The results of elastic analysis method for seismic performance evaluation show that the effect of piloti and building height decrease performance index. In case of shear wall building, the state of insufficient shear stress governs their overall performance and it becomes evident in the case of the buildings with more than 25 stories. For the buildings of piloti, the change of mass, weak story, as well as insufficient shear stress, decrease the performance index rapidly compared with the performance index of the buildings without piloti. The results, obtained from the nonlinear static analysis using capacity spectrum method, indicate that the performance Point increases for the structure having Piloti and high story. Also, deformation limits of buildings satisfy the allowable criteria at the life safety level, but the immediate occupancy level is exceeded in buildings which have more than 25 stories.

Design and evaluation of a VPRS-based misbehavior detection scheme for VANETs (차량애드혹망을 위한 가변정밀도 러프집합 기반 부정행위 탐지 방법의 설계 및 평가)

  • Kim, Chil-Hwa;Bae, Ihn-Han
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.6
    • /
    • pp.1153-1166
    • /
    • 2011
  • Detecting misbehavior in vehicular ad-hoc networks is very important problem with wide range of implications including safety related and congestion avoidance applications. Most misbehavior detection schemes are concerned with detection of malicious nodes. In most situations, vehicles would send wrong information because of selfish reasons of their owners. Because of rational behavior, it is more important to detect false information than to identify misbehaving nodes. In this paper, we propose the variable precision rough sets based misbehavior detection scheme which detects false alert message and misbehaving nodes by observing their action after sending out the alert messages. In the proposed scheme, the alert information system, alert profile is constructed from valid actions of moving nodes in vehicular ad-hoc networks. Once a moving vehicle receives an alert message from another vehicle, it finds out the alert type from the alert message. When the vehicle later receives a beacon from alert raised vehicle after an elapse of time, then it computes the relative classification error by using variable precision rough sets from the alert information system. If the relative classification error is lager than the maximum allowable relative classification error of the alert type, the vehicle decides the message as false alert message. Th performance of the proposed scheme is evaluated as two metrics: correct ratio and incorrect ratio through a simulation.