• Title/Summary/Keyword: Department of Radiologic Science

Search Result 352, Processing Time 0.024 seconds

Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography (치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과)

  • Lee, Tae Hui;Jeong, Seung Hun;Kim, Dong Woo;Park, Myeong Hwan;Kim, Tae-Hyung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.459-464
    • /
    • 2019
  • In order to minimize the radiation exposure dose of the thyroid site at dental cone-beam computer tomography, a protector using a Bolus was prepared, and the radiation shielding effect and the appropriateness of the image were evaluated. Using a dental cone-beam computed tomography (CBCT), a glass dosimeter was attached to the left and right sides of the thyroid for a dental radiation phantom, and the radiation dose was measured. The absorbed dose for each shield was measured by another method to 10 mm, 20 mm, and 30 mm-thickness, respectively. Eight evaluators evaluated whether or not the medical image is appropriate. When using a 30 mm Bolus shield at the left thyroid site, the resulting value is reduced by an average of $342.67{\mu}Gy$ by 20.7% from the average value of $431.22{\mu}Gy$ measured without using a Bolus shield, the right thyroid site In the case of using 30 mm Bolus shield, it showed a dose reduction effect of 21.9% with an average of $424.56{\mu}Gy$. The adequacy of the medical image was judged to be usable by both evaluators. In conclusion, the dental cone-beam computerized tomography can be used as a useful shielding material because it has a radiation shielding effect and it is possible to treat the diagnosis of the bolus protector in the thyroid without any obstruction shade in order to minimize the radiation dose.

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

USEFULNESS OF ACELLULAR DERMAL MATRIX GRAFT ON THE TISSUE REGENERATION IN RABBITS (가토에서 조직 재생 이식재로서 무세포성 진피 기질의 효용)

  • Choi, Jong-Hak;Ryu, Jae-Young;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.220-229
    • /
    • 2008
  • Purpose: The present study was aimed to examine the effect of acellular dermal matrix ($AlloDerm^{(R)}$) grafted to the experimental tissue defect on tissue regeneration. Materials and Methods: Male albino rabbits were used. Soft tissue defects were prepared in the external abdominal oblique muscle. The animals were then divided into 3 groups by the graft material used: no graft, autogenous dermis graft, and $AlloDerm^{(R)}$ graft. The healing sites were histologically examined at weeks 4 and 8 after the graft. In another series, critical sized defects with 8-mm diameter were prepared in the right and left iliac bones. The animals were then divided into 5 groups: no graft, grafted with autogenous iliac bone, $AlloDerm^{(R)}$ graft, $AlloDerm^{(R)}$ graft impregnated with rhBMP-2, and $AlloDerm^{(R)}$ graft with rhTGF-${\beta}1$. The healing sites of bone defect were investigated with radiologic densitometry and histological evaluation at weeks 4 and 8 after the graft. Results: In the soft tissue defect, normal healing was seen in the group of no graft. Inflammatory cells and foreign body reactions were observed in the group of autogenous dermis graft, and the migration of fibroblasts and the formation of vessels into the collagen fibers were observed in the group of $AlloDerm^{(R)}$ graft. In the bone defect, the site of bone defect was healed by fibrous tissues in the group of no graft. The marked radiopacity and good regeneration were seen in the group of autogenous bone graft. There remained the traces of $AlloDerm^{(R)}$ with no satisfactory results in the group of $AlloDerm^{(R)}$ graft. In the groups of the $AlloDerm^{(R)}$ graft with rhBMP-2 or rhTGF-${\beta}1$, there were numerous osteoblasts in the boundary of the adjacent bone which was closely approximated to the $AlloDerm^{(R)}$ with regeneration features. However, the fibrous capsule also remained as in the group of $AlloDerm^{(R)}$ graft, which separated the $AlloDerm^{(R)}$ and the adjacent bone. Conclusions: These results suggest that $AlloDerm^{(R)}$ can be useful to substitute the autogenous dermis in the soft tissue defect. However, it may not be useful as a bone graft material or a carrier, since the bone defect was not completely healed by the bony tissue, regardless of the presence of osteogenic factors like rhBMP-2 or rhTGF-${\beta}1$.

Evaluation of the dose distribution in Mapcheck using Enhanced Dynamic Wedge (Enhanced Dynamic Wedge를 사용한 Mapcheck에서의 선량분포 평가)

  • Kang, Su-Man;Jang, Eun-Sun;Lee, Byung-Koo;Jung, Bong-Jae;Shin, Jung-Sub;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.343-349
    • /
    • 2012
  • Intensity Modulated Radiotherapy (IMRT) is increasing its use recently due to its benefits of minimizing the dose on surrounding normal organs and being able to target a high dose specifically to the tumor. The study aims to measure and evaluate the dose distribution according to its dynamic changes in Mapcheck. In order to verify the dose distribution by EDW angle($10^{\circ}$,$15^{\circ}$,$20^{\circ}$,$25^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$), field size (asymmetric field) and depth changes (1.5 cm, 5.0 cm) using IMRT in Clinac ix, a solid phantom was placed on the Mapcheck and 100MU was exposed by 6 MV, 10MV X-ray. Using a 6MV, 10MV energy, the percentage depth dose according to a dynamic changes at a maximum dose depth (1.5 cm) and at 5.0 cm depth showed the value difference of maximum 0.6%, less than 1%, which was calculated by a treatment program device considering the maximum dose depth at the center as 100%, the percentage depth dose was in the range between 2.4% and 7.2%. Also, the maximum value difference of a percentage depth dose was 4.1% in Y2-OUT direction, and 1.7% in Y1-IN direction. When treating a patient using a wedge, it is considered that using an enhanced dynamic wedge is effective to reduce the scattered dose which induces unnecessary dose to the surroundings. In particular, when treating a patient at clinic, a treatment must be performed considering that the wedge dose in a toe direction is higher than the dose in a heel direction.

Development and Application of Case-Based Learning Program for Occupational Personality Education of Health Care Worker (보건의료종사자 맞춤형 직업인성교육을 위한 사례기반학습 프로그램 개발 및 적용)

  • Yang, Eun Ju;Kim, Hye Ran;Chang, Jeong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.371-379
    • /
    • 2021
  • The personality education of the existing university is mainly focused on occupational ethics education or basic education, but the purpose and method of the personality education program is changed in preparation for the 4th industry and the related occupational personality education program is needed. In Korea, however, there is a lack of research on the development of educational programs for occupational personalities that Health care workers should have. Therefore, this study aims to confirm the effect by developing and applying a program for occupational personality education for Health care workers required for the 4th Industrial Revolution based on case-based learning. In this study, general cases and occupational cases were developed, and research tools were developed to verify the effectiveness of the occupational personality education program. The program developed in this study was provided four times for 52 students in the second and third grades college and university. This study was performed with a single group pre-post design. The data were analyzed by means of mean, standard deviation, and paired t-test. By applying the program developed in this study, accountability, honesty, consideration, collaboration, communication, and competency were improved. This confirmed the positive effect of vocational character education

Evaluation of Radiation Dose and Imaging of the QC Program in Mammography MLO View (MLO View의 유방촬영에서 QC 프로그램을 이용한 선량 및 영상 평가)

  • Lee, Seon-Hwa;Kim, Jung-Min;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.221-228
    • /
    • 2015
  • Purpose: In digital mammography QC program was used for the purpose of reducing low-dose and high-definition images of the radiation dose. Materials and Methods: In digital mammography using a QC phantom according to the average glandular dose in the exposure method MLO view $0^{\circ}C$, $30^{\circ}C$, $45^{\circ}C$, $50^{\circ}C$, $55^{\circ}C$, $70^{\circ}C$, was measured at $90^{\circ}C$ intervals, an image with Hologic QC program to the SNR and CNR was measured to evaluate. Results: The average dose in the MLO view was wired to $90^{\circ}C$ when the maximum was 1.75 mGy, it decreased approximately 6% was measured at $45^{\circ}C$ 1.65 mGy. In addition, 1.67 mGy, manual record, there were an average wired in accordance with the exposure dose and the dose of 1.52 mGy difference in the way auto filter. Image quality evaluation at every angular section SNR 50 ~ 52, shows a slight difference in CNR 11 ~ 12, it was included in the manufacturer's recommended value. Conclusion: The dose was lowest in MLO view $45^{\circ}C$, the difference between SNR and CNR were insignificant. The method of exposure will need a way to reduce the exposure of the patient's body or unnecessary patient by placing a difference in settings in which the characteristics.

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

Radiation Dose and Estimate of Lifetime Attributable Risk of Cancer from Coronary Angiography and Percutaneous Coronary Intervention (관상동맥조영술과 경피적관상동맥중재술에서 환자 선량과 암 발생 생애귀속위험 평가)

  • Kang, Yeong-Han;Kim, Bu-Sun;Park, Jong-Sam
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.213-221
    • /
    • 2010
  • The Purpose of this study was to determine the effective dose to an average patient from Coronary Angiography (CA) and Percutaneous Coronary Intervention (PCI). And to estimate the lifetime attributable risk (LAR) of cancer associated with radiation exposure from CA and PCI. The dose-area product (DAP) values to the patient were recorded from 60 CA and 58 PCI. A Monte Carlo based program PCXMC was used to calculate the effective dose from DAP values for each patient. Lifetime attributable risks were estimated with models developed in the National Academies' Biological Effects of Ionizing Radiation VII report. The mean DAP values was $53.76\;Gy{\cdot}cm^2$ for CA and $165.82\;Gy{\cdot}cm^2$ for PCI. Mean effective dose were 1.28 mSv in CA, 3.94 mSv in PCI. Results of Calculate organ dose, lung doses was 2.17 mSv in CA and 6.71 mSv in PCI. Female breast doses was 5.45 mSv in CA and 16.82 mSv in PCI. LAR estimates for CA varied from 1 in 1,508 for man to 1 in 1,357 for women. In PCI procedure varied from 1 in 553 for man to 1 in 482 for women. DAP can be used as the dose indicator to calculate the organ dose and effective dose of patient based on Monte Carlo simulation. These dose estimates derived from our simulation models suggest that CA and PCI are associated with a nonnegligible LAR of cancer. This risk varies markedly and is considerably greater for women, PCI than for man, CA.

Clinical Features of Symptomatic Meckel's Diverticulum in Children: Comparison of Scintigraphic and Non-scintigraphic Diagnosis

  • Rho, Jung Hee;Kim, Jae Sook;Kim, Sang Yong;Kim, Soon Ki;Choi, Yoon Mi;Kim, Sung Min;Tchah, Hann;Jeon, In Sang;Son, Dong Woo;Ryoo, Eell;Cho, Kang Ho;Choi, Deok Young;Kim, Yoon Mi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • Purpose: Meckel's diverticulum (MD) has various clinical manifestations, and diagnosis or selectection of proper diagnostic tools is not easy. This study was conducted in order to assess the clinical differences of MD diagnosed by scintigraphic and non-scintigraphic methods and to find the proper diagnostic tools. Methods: We conducted a retrospective review ofthe clinical, surgical, radiologic, and pathologic findings of 34 children with symptomatic MD, who were admitted to Gachon University Gil Medical Center, Inha University Hospital, and The Catholic University of Korea, Incheon St. Mary's Hospital between January 2000 and December 2012. The patients were evaluated according to scintigraphic (12 cases; group 1) and non-scintigraphic (22 cases; group 2) diagnosis. Results: The male to female ratio was 7.5: 1. The most frequent chief complaint was lower gastrointestinal (GI) bleeding in group 1 and nonspecific abdominal pain in group 2, respectively. The most frequent pre-operative diagnosis was MD in both groups. Red blood cell (RBC) index was significantly lower in group 1. MD was located at 7 cm to 85 cm from the ileocecal valve. Four patients in group 1 had ectopic gastric tissues causing lower GI bleeding. The most frequent treatment modality was diverticulectomy in group 1 and ileal resection in group 2, respectively. Conclusion: To diagnose MD might be delayed unless proper diagnostic tools are considered. It is important to understand indications of scintigraphic and non-scintigraphic methods according to clinical and hematologic features of MD. Scintigraphy would be weighed in patients with anemia as well as GI symptoms.

Two Cases of Acute Respiratory Distress Syndrome with Pulmonary Hemorrhage Induced by Injection of Silicone at Perineum (외음부의 실리콘액 주사에 의한 폐출혈 및 급성 호흡 곤란 증후군 2예)

  • Kang, So-Eun;Yong, Suk-Joong;Lee, Won-Yeon;Shin, Pyo-Jin;Kim, Mi-Hae;Park, Hark-Cheon;Shim, Myung-Sook;Choi, Hyun-Min;Shin, Kye-Chul;Lim, Mi-Ae;Yang, Kyung-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.2
    • /
    • pp.166-172
    • /
    • 2001
  • Silicone fluid is a biomaterial widely used in modern cosmetic procedures because there are few side effects, considerable chemical stability and predictable physical properties. However, many local and systemic adverse reactions have reported. In particular some serious pulmonary complications have been reported such as pulmonary thromboembolism, acute respiratory distress syndrome with some cases leading to mortality. Most of the serious complicated cases were induced by an illegal silicone fluid injection. We experienced two cases of acute respiratory distress syndrome with pulmonary hemorrhage induced by an illegal silicone fluid injection. The patients were 41 & 51 year old women, who complained of dyspnea. The chest X-ray and HRCT scan findings showed a bilateral ground glass attenuation on the bilateral dependent portion of the upper and middle lung zone. The patients clinical symptoms and the radiologic and other laboratory findings were compatible with acute respiratory distress syndrome induced by the silicon fluid injection. Here we report two cases of acute respiratory distress syndrome with pulmonary hemorrhage induced by an illegal silicone injection with a review of the relevant literature.

  • PDF