Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography  

Lee, Tae Hui (Department of Radiology, Wonju Medical Center)
Jeong, Seung Hun (Department of Radiology, Wonju Medical Center)
Kim, Dong Woo (Department of Radiology, Wonju Medical Center)
Park, Myeong Hwan (Department of Radiologic Technology, Daegu Health College)
Kim, Tae-Hyung (Department of Radiological Science, College of Health Science, Kangwon National University)
Publication Information
Journal of the Korean Society of Radiology / v.13, no.3, 2019 , pp. 459-464 More about this Journal
Abstract
In order to minimize the radiation exposure dose of the thyroid site at dental cone-beam computer tomography, a protector using a Bolus was prepared, and the radiation shielding effect and the appropriateness of the image were evaluated. Using a dental cone-beam computed tomography (CBCT), a glass dosimeter was attached to the left and right sides of the thyroid for a dental radiation phantom, and the radiation dose was measured. The absorbed dose for each shield was measured by another method to 10 mm, 20 mm, and 30 mm-thickness, respectively. Eight evaluators evaluated whether or not the medical image is appropriate. When using a 30 mm Bolus shield at the left thyroid site, the resulting value is reduced by an average of $342.67{\mu}Gy$ by 20.7% from the average value of $431.22{\mu}Gy$ measured without using a Bolus shield, the right thyroid site In the case of using 30 mm Bolus shield, it showed a dose reduction effect of 21.9% with an average of $424.56{\mu}Gy$. The adequacy of the medical image was judged to be usable by both evaluators. In conclusion, the dental cone-beam computerized tomography can be used as a useful shielding material because it has a radiation shielding effect and it is possible to treat the diagnosis of the bolus protector in the thyroid without any obstruction shade in order to minimize the radiation dose.
Keywords
cone-beam computed tomography; thyroid gland; radiation protection; dentistry;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 http://kostat.go.kr/portal/korea/kor_nw/2/1/index.board?bmode=read&aSeq=363362, 2017.
2 http://www.nhis.or.kr/bbs7/boards/B0075/24637, 2016.
3 S. Zhao, D. D. Robertson, G. Wang, "X-ray CT metal artifact reduction using wavelets an application for imaging total hip prostheses," IEEE Trans Med Imaging, Vol. 19, No. 12, pp. 1238-1247, 2000.   DOI
4 http://www.khiss.go.kr/board?pageNum=3&rowCnt=10&menuId=MENU00328&schType=0&schText=medicaldevicemarket&boardStyle=&categoryId=&continent=&schStartChar=&schEndChar=&country=&upDown=0, 2013.
5 http://opendata.hira.or.kr/op/opc/olapDiagBhvInfo.do, 2016.
6 G. S. Shin, Y. H. Kim, B. R. Lee, "The Actual State and the Utilization for Dental Radiography in Korea," JRST, Vol. 33, No. 2, pp. 109-120, 2010.
7 http://ncc.re.kr/prBoardView1.ncc?nwsId=3380&searchKey=total&searchValue&pageNum=1, 2015.
8 D. C. Kweon, K. R. Dong, J. E. Jung, "A Literature Review and Analysis of Dosimetry in Panoramic Radiography," JRST, Vol. 33, No. 1, pp. 1-10, 2010.
9 Association of Korean Professors of Oral and Maxillofacial Radiology, Oral and maxillofacial radiology, 4th ed. pp. 138-143, Narae Publishing, Inc. 2008.
10 H. R. Lee, H. Y. Kim, H. W. Choi, et. al, "The effect of a Thyroid Shield Made of a Tissue-Equivalant Material on the Reduction of the Thyroid Exposure Dose in Panoramic Radiography," Journal of the Korea Academia-Industrial cooperation Society, Vol. 13, No. 5, pp. 2278-2284. 2012.   DOI
11 C. S. Jeong, E. H. Mo, G. H. Lee, "A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals," JKSR, Vol. 5, No. 6, pp. 370-374, 2011.
12 W. De Vos, J. Casselman, G. R. J. Swennen, "Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region A systematic review of the literature," International Journal of Oral and Maxillofacial Surgery, Vol. 38, No. 6, pp. 609-625, 2009.   DOI
13 E. T. Lee, G. T. Kim, Y. S. Choi, "Radiation absorbed doses of cone beam computed tomography," JKOMR, Vol. 37, No. 2, pp. 87-90, 2007.
14 K. Tsiklakis, C. Donta, S. Gavala, "Dose reduction in Maxillofacial imaging using low dose Cone Beam CT," European Journal of Radiology, Vol. 56, No. 3, pp. 413-419, 2005.   DOI
15 C. P. Shortt, N. F. Fanning, L. Malone, "Thyroid Dose During Neurointerventional Procedures Does Lead Shielding Reduce the Dose?," CardioVascular and Interventional Radiology, Vol. 30, No. 5, pp. 922-927, 2007.   DOI