• 제목/요약/키워드: Dental resin monomer

검색결과 31건 처리시간 0.025초

Bonding of conventional provisional resin to 3D printed resin: the role of surface treatments and type of repair resins

  • Lim, Na-Kyung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.322-328
    • /
    • 2020
  • PURPOSE. This study evaluated the shear bond strength between 3D printed provisional resin and conventional provisional resin depending on type of conventional provisional resin and different surface treatments of 3D printed resin. MATERIALS AND METHODS. Ninety-six disc-shaped specimens (Ø14 mm × 20 mm thickness) were printed with resin for 3D printing (Nextdent C&B, Vertex-Dental B. V., Soesterberg, Netherlands). After post-processing, the specimens were randomly divided into 8 groups (n=12) according to two types of conventional repair resin (methylmethacrylate and bis-acryl composite) and four different surface treatments: no additional treatment, air abrasion, soaking in methylmethacrylate (MMA) monomer, and soaking in MMA monomer after air abrasion. After surface treatment, each repair resin was bonded in cylindrical shape using a silicone mold. Specimens were stored in 37℃ distilled water for 24 hours. The shear bond strength was measured using a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were analyzed by scanning electron microscope. Statistical analysis was done using one-way ANOVA test and Kruskal-Wallis test (α=.05). RESULTS. The group repaired with bis-acryl composite without additional surface treatment showed the highest mean shear bond strength. It was significantly higher than all four groups repaired with methylmethacrylate (P<.05). Additional surface treatments, neither mechanical nor chemical, increased the shear bond strength within methylmethacrylate groups and bis-acryl composite groups (P>.05). Failure mode analysis showed that cohesive failure was most frequent in both methylmethacrylate and bis-acryl composite groups. CONCLUSION. Our results suggest that when repairing 3D printed provisional restoration with conventional provisional resin, repair with bis-acryl composite without additional surface treatment is recommended.

Effect of Hydrophobic, Neutral Adhesive on the Dentin Bond Strength of Self-etching Adhesive

  • Bae, Ji-Hyun;Choi, Yong-Hoon;Jung, Moon-Kyung;Cho, Byeong-Hoon
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.5-11
    • /
    • 2009
  • Objectives : This study investigated the hypothesis that the dentin bond strength of self-etching adhesives (SEAs) may be improved by applying a coat of hydrophobic, neutral adhesive resin in addition to SEA. Method and Materials : The bond strengths of two SEAs - Experimental SEA (EX) and Adper Prompt (AP) - were measured with three bonding protocols. The D/E resin of All-Bond 2 was applied as the hydrophobic, neutral adhesive. Clearfil SE Bond (SE, self-etching primer system) and All-Bond 2 (AB, total etching system) were used as references. The following protocols were used: (1) EX1 (EX 1 coat); (2) EX2 (EX 2 coats); (3) EX+ (EX 1 coat + D/E resin); (4) AP1 (AP 1 coat); (5) AP2 (AP 2 coats); (6) AP+ (AP 1 coat + D/E resin); (7) SE (SE primer + SE bond); (8) SE+ (SE primer + D/E resin); (9) AB (etching + AB primer + D/E resin). Filtek Z250 composite resin was built up and the microtensile bond strength (MTBS) values of the specimens were compared. The fractured surfaces were observed using SEM. Results : When SEA was used as self-etching primer and hydrophobic, neutral adhesive was applied as well, MTBS was significantly higher than that when either one coat or two coats of SEA only were used (p < 0.05). Conclusion : The hydrophobic, neutral adhesive improved the integrity of the bonded interface obtained with SEA.

  • PDF

액상 amine 광개시제에 따른 치과용 복합수지의 중합효율 (Photopolymerization Efficiency of Dental Resin Composites with Novel Liquid Amine Photoinitiators)

  • 선금주
    • 치위생과학회지
    • /
    • 제8권3호
    • /
    • pp.109-115
    • /
    • 2008
  • 치과용 가시광선 중합형 복합수지의 광중합효율을 높이기 위해 2종의 새로운 액체형 amine 개시제인 MA, MPT와 현재 가장 많이 사용되고 있는 개시제인 AEM을 CQ, PD, DA에 각각 첨가하고 UDMA의 광중합효율을 알아본 결과 다음과 같은 결론을 얻었다. 1. 조사시간이 증가됨에 따라 amine 개시제의 종류에 관계없이 광중합효율이 점차 증가되었으며, 약 60초까지 조사였을 때에는 광중합효율이 급격히 증가되었으나 그 이상 조사하여도 광중합효율이 크게 증가되지 않았다. 2. AEM, MA와 MPT를 사용하였을 경우 모두 CQ > PD > DA의 순으로 광중합효율이 우수하게 나타났으나 AEM을 사용하였을 때 PD와 CQ는 큰 차이를 보이지 않았다. 3. CQ의 광중합효율은 새로운 광개시제인 MA와 MPT를 사용하였을 때가 범용으로 사용되고 있는 amine 개시제인 AEM을 사용하였을 경우보다 중합효율이 증가하는 결과를 보였다. 4. PD의 광중합효율은 MA와 함께 사용하였을 경우가 가장 높게 나타났으나 AEM의 경우와 큰 차이를 보이지는 않았다. 5. 이상의 결과로부터 MA와 CQ 및 PD를 함께 사용한 새로운 광중합시스템이 광중합효율을 높이는데 효율적인 것을 알 수 있었다.

  • PDF

화학적 표면처리에 따른 의치상 레진과 이장재 간의 전단 결합강도 (Effects of chemical surface treatment on the shear bond Strength of denture reliners and denture base resin)

  • 최에스더;권은자
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5745-5751
    • /
    • 2013
  • 본 논문은 monomer에서 결합증진에 많은 역할을 하는 MMA와 TEGDMA의 농도별 표면 처리와 silane coupling agent로 표면 처리한 것이 의치상 레진과 이장재간의 결합력에 미치는 영향에 대해 알아보고자 하였다. 의치상 레진에 MMA와 TEGDMA의 농도별 표면 처리와 silane coupling agent로 표면처리 후 이장재를 주입하여 전단결합강도를 측정하였다. MMA와 TEGDMA의 농도별 표면 처리에 따른 의치상 레진과 이장재간의 전단결합강도에서는 Vertex self curing resin에서 95%, 90%, 80%, Kooliner에서는 95%, 90%에서 유의적으로 높게 나타났다(P<0.05). 또한, silane coupling agent 5%로 표면 처리한 그룹이 Vertex self curing resin과 Kooliner 모두에서 전단결합강도가 유의적으로 높게 나타났다(P<0.05). 따라서 적절한 화학적 표면 처리는 의치상 레진과 이장재간의 결합력 증가에 영향을 미치리라 사료된다.

어린이 음료가 레진계 치면열구전색제의 화학적 분해에 미치는 영향 (The Effect of Children's Beverages on Degradation of Dental Resin-Based Pit and Fissure Sealant)

  • 민희홍;김현진;이혜진
    • 치위생과학회지
    • /
    • 제18권6호
    • /
    • pp.367-373
    • /
    • 2018
  • 시판 중인 어린이 음료가 레진계 치면열구전색제에 미치는 물리 화학적 영향을 알아보기 위해 판매량이 높은 3종의 어린이 음료와 대조군으로 생수를 선정하였다. 제조사의 지시에 따라 레진 시편을 제작하여 시편의 초기 거칠기 값(Ra)를 측정하였고, 각 음료의 pH를 측정한 후, 레진 시편을 각각의 음료에 침지시켜 $37^{\circ}C$ 배양기에서 72시간 보관하였다. 72시간 후 레진 시편의 표면 거칠기를 측정하였고 시편 표면의 형태변화 관찰을 위해 주사전자현미경으로 관찰하였다. 레진 시편에서 용출된 단량체의 종류 및 용출량은 HPLC를 이용하여 비교 분석하였다. 생수를 제외한 모든 실험음료에 구연산이 첨가되어 있었고 어린이 음료의 평균 pH는 $3.25{\pm}0.17$로 '아이키커'에서 $3.03{\pm}0.01$로 가장 낮았고 '뽀로로'에서 $3.47{\pm}0.02$로 가장 높았다. 어린이 음료에 침지 후 시간 경과에 따른 표면 거칠기가 증가하였고 레진 시편의 표면에 기질의 탈락을 관찰하였다. 모든 실험음료에서 bis-GMA는 유출되지 않았으나 생수를 제외한 어린이 음료에서는 TEGDMA가 유출되었다. 이상의 결과 어린이 음료는 치면열구전색제의 열화와 단량체의 유리를 촉진할 수 있으며 유리된 단량체는 성장 중인 어린이에게 더 큰 영향을 미칠 수 있으므로 어린이 음료를 빈번히 음용하는 것은 주의가 필요하다.

Orthodontic Acrylic Resin의 중합조건 변화가 최대하중에 미치는 영향 (The Effect of Changes in Polymerization Conditions of Orthodontic Acrylic Resin on Maximum Load)

  • 이규선
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.127-136
    • /
    • 2013
  • Purpose: In order to find out the impact of changes in polymerization conditions of orthodontic acrylic resin on maximum load. Methods: While maintaining mixing ratio 3:1 of polymer and monomer in spray-on way in the production condition of polymerization temperature $25^{\circ}C$ or $37^{\circ}C$ for 10 minutes or 30 minutes of polymerization time by pressure $3kfg/cm^2$ or $6kfg/cm^2$ in the lab maintaining $25^{\circ}C$ of room temperature, the change in maximum load rise rate was tested by producing 5 acrylic resin specimens for orthodontics per group to meet the standards of $25mm{\times}2mm{\times}2mm$ and using INSTRON with the 3rd bar 2mm in diameter and parallel support bending device of $15{\pm}0.1mm$ as test equipment showing 30.00mm/min of crosshead speed, $50{\pm}16$ N/min of load ratio in the laboratory of $24^{\circ}C$ room temperature and as a result, the following results were obtained. Results: 1. When increasing pressure from $3kfg/cm^2$ to $6kfg/cm^2$, maximum load was lowered by -4.285%. 2. When increasing polymerization time from 10 minutes to 30 minutes, maximum load rose by 3.848%. 3. When increasing polymerization temperature from $27^{\circ}C$ to $37^{\circ}C$, maximum load rose by 5.854%. Conclusion: Considering the above test results that polymerization time and polymerization temperature when polymerizing acrylic resin for orthodontics according to changes in working conditions had an impact on the rate of rise of maximum load values but the rate of rise was lowered when increasing pressure from $3kfg/cm^2$ to $6kfg/cm^2$, we came to a conclusion that high pressure more than necessary does not affect the rate of rise of maximum load.

새로운 레진 단량체가 복합레진수복물의 미세변연누출에 미치는 영향 (EFFECT OF A NEW RESIN MONOMER ON THE MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS)

  • 배지현;김영균;윤필영;이미애;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제32권5호
    • /
    • pp.469-475
    • /
    • 2007
  • 본 연구는 물성의 단점이 많은 희석재인 TEGDMA의 사용을 줄이기 위해, Bis-GMA의 유도체로서 중합수축이 적고 점도가 낮은 새로운 단량체인 methoxlyated Bis-GMA (Bis-M-GMA)를 첨가한 복합레진의 법랑질과 상아질 변연에서의 미세누출을 비교하였다. 40개의 발거된 상하악 소구치의 협면과 설면에 $2\;mm\;{\times}\;2\;mm\;{\times}\;2\;mm$ 와동을 형성하여 4개 군으로 분류하였다. Clearfil SE bond와 복합레진을 이용하여 와동을 수복하였다. EX1군은 실험용 복합레진 1 (Bis-M-GMA/TEGDMA = 95/5wt% ,40 nm 나노필러 함유), EX2군은 실험용 복합레진 2 (Bis-M-GMA/TEGDMA = 95/5wt%, 20 nm 나노필러 함유), EX3군은 실험용 복합레진 3 (Bis-GMA/TEGDMA = 70/30wt%, 40 nm 나노필러 함유), Z250군은 Filtek 2250으로 각각 와동을 수복하였다. 모든 시편은 실온의 실온의 생리식염수에서 7일간 보관한 후, $5^{\circ}C$$55^{\circ}C$ 의 수조에서 500회의 열순환을 실시하고, 2% methylene blue염색 용액에 24시간 담근 후, 협설측으로 치아 장축에 평행하게 절단하고 광학입체현미경하에서 각 수복물의 법랑질과 상아질 변연부의 색소침투 정도를 관찰하여 미세누출점수로 기록한 후 각 군의 유의성을 검증하였다. 법랑질 변연이 상아질 변연보다 유의성있게 낮은 미세변연누출을 보였다 (p = 0.007). 각 변연에서 EX1, EX2보다 EX3, Z250군의 염색침투도가 증가하는 경향을 보였지만 통계적으로 유의성 있는 차이를 보이지는 않았다 (p > 0.05). 점도가 낮은 새로운 레진단량체인 Bis-M-GMA는 기존의 단량체인 Bis-GMA의 대체재로 고려될 수 있다.

각종 치과용 다이렉트 레진의 중합 반응시 열 측정 (The Measurement of Exothermic Temperature During Polymerization of Various Direct Resins.)

  • 윤중현
    • 대한치과의사협회지
    • /
    • 제11권1호
    • /
    • pp.37-40
    • /
    • 1973
  • The auther measured exothermic tempreature of the 5 kinds of direct resins during polymerization. Direct resins were mixed into the rubber cup(550-600㎣ in volume) with grass rod at room temperature (23.6℃) for 30 seconds and thermometer was placed approximately at the geometric center of the resin mass in the rubber cup. Polymer-monomer ratio was determined by instruction of the packages. The results were as follows. 1) The heat generated during polymerization was under 47.3℃. 2) The time at which the highest temperature is reached during polymerization was within 20.5 minutes. 3) Slow curing resins produced lower heat than quick curing resins and quick curing resins presented higher temperature than slow curing resins. 4) The highest temperature was sustained momentarily.

  • PDF

복합레진을 이용한 전치부의 수복

  • 박성호
    • 대한치과의사협회지
    • /
    • 제34권12호통권331호
    • /
    • pp.855-860
    • /
    • 1996
  • 치과용 복합레진은 bis GMA형의 monomer가 개발되고, 무기 filler가 첨가되어 물리적인 성질이 더욱 향상되었으며, 또한 법랑질에 대한 산부식법을 통하여 치아에 대한 결합력을 높을 수 있는 방법이 도입되면서 치과용 수복물로서 각광을 받아 왔다. 특히 복합레진은 이전까지 이용되었던 silicate cement 이나 acrylic resin에 비하여 변색이 적고, 원래의 형태를 비교적 잘 유지하는 장점을 가져서 전치부의 수복에 유용한 재료로 인식되었다. 복합레진을 이용한 전치부의 수복은 비교적 적은 치질의 삭제만으로도 가능하고, 심미적으로도 우수한 결과를 보이고 있어서 올바른 술식을 통하여 적절히 이용한다면 좋은 임상적인 결과를 얻을 수 있는 것이 사실이지만 재료학적인 한계가 아직 까지는 엄연히 존재한다. 복합레진을 이용한 전치부의 수복에 있어서, 복합레진의 문제점과 이를 줄이기 위한 방법, 임상시의 주의점 등에 관해 살펴보도록 한다.

  • PDF

중합시간과 중합방법에 따른 자가중합형 상교정용 레진의 중합률의 비교에 관한 연구 (A STUDY ON THE DEGREE OF POLYMERIZATION OF AUTOPOLYMERIZED RESIN FOR REMOVABLE ORTHODONTIC APPLIANCE ACCORDING TO CURING TIME AND CURING METHOD)

  • 유종욱;장기택;김종철
    • 대한소아치과학회지
    • /
    • 제26권2호
    • /
    • pp.296-309
    • /
    • 1999
  • 가철성 상교정 장치에 많이 사용되는 자가중합형 상교정용 레진의 미반응 단량체는 레진의 물성과 생물학적인 면에 많은 영향을 끼친다. 따라서 미반응 단량체를 최소화하고 중합률을 최대로 하는 중합방법에 대한 연구는 중요한 의의를 갖는다. 저자는 자가중합형 상교정용 레진의 중합시간과 중합방법에 따른 중합률을 비교해보기 위해 시편을 다음과 같이 5군으로 나누어 연구를 진행하였다. 상교정용 레진의 분말과 용액을 혼합하여 제 1군은 $28^{\circ}C$의 공기중에 보관하였고, 제 2군은 $28^{\circ}C$의 물에, 제 3군은 $28^{\circ}C$의 물과 30psi의 압력에, 제 4군은 $43^{\circ}C$의 물에, 제 5군은 $43^{\circ}C$의 물과 30psi의 압력하에 각각 보관하였고, 10분, 1시간, 12시간, 1일, 3일 경과 후에 각 시편을 Fourier 변환적외선분광법을 이용하여 중합률을 측정하여 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합시간이 경과함에 따라 중합률도 지속적으로 증가하는 양상을 보였다. 10분 경과 후의 결과와 비교하여 볼 때, 제 1군은 12시간 경과 후부터 중합률의 증가가 유의성이 있었고, 제 2군과 3군, 4군, 5군은 1시간 경과 후부터 유의성이 있었다(p<0.05). 2. 10분과 1일, 3일 경과 후에 제 5군, 제 4군, 제 3군, 제 2군, 제 1군의 순서대로 중합률이 높았다. 3. 중합시 온도에 따른 비교에서, 1일 경과 후를 제외하고는 모든 시간에서 $43^{\circ}C$에서 중합시킨 군의 중합률이 $28^{\circ}C$에서 중합시킨 군의 중합률 보다 유의성 있게 높았다(p<0.05). 4. 압력은 12시간 경과 후를(p<0.05) 제외하고는 중합률에 영향을 주지 못했다. 5. 보관방법은 1시간 경과 후를(p<0.05) 제외하고는 중합률에 영향을 주지 못했다.

  • PDF