• Title/Summary/Keyword: Dental prosthesis

Search Result 791, Processing Time 0.027 seconds

Implant-assisted removable partial denture using milled bar and Locator in partially edentulous maxilla: A case report (상악 부분 무치악 환자에서 Milled Bar와 Locator를 이용한 임플란트 융합 국소의치수복 증례)

  • Kim, Ji-Hyun;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, Hyeon-Jong;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.137-144
    • /
    • 2020
  • Implant-fixed prostheses and removable partial dentures are widely used as a traditional treatment method for partially edentulous patients who have lost multiple teeth. Recently, there has been increasing interest in implant-assisted removable partial denture (IARPD), which additionally obtains retention and support using a small number of implants. The IARPDs have higher retention, stability, and aesthetics than conventional removable dentures. It also has the effect of reducing the cost as well as the burden of surgery by placing a small number of implants at the edentulous site. In this case, the patient with a partial edentulous state that has multiple numbers of tooth loss in maxilla initially planned to be treated with implant fixed prosthesis. However, the treatment plan was changed to IARPD using Bar and Locator due to several factors. The clinical results were satisfactory on the aspect of esthetic and masticatory function.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

A Study on the Effects of Local Factors on the Oral Ulcers Observed in Behcet s Disease (베체트 병의 구강궤양에 대한 국소인자의 영향에 관한 연구)

  • Myoung-Chan Kim;Chong-Youl Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.2
    • /
    • pp.75-86
    • /
    • 1992
  • Of the many first-occuring major manifestations of Behcet's disease, the oral ulcer is most frequently observed, shows the highest mean recurrence rate, and the longest mean duration period. A study of the relationship between mechanical irritation buy local factors and the recurrence of oral ulcers was carried out to see if there is a correlation. The subjects chosen for the study were 81 patients who were referred to the Department of Oral Diagnosis at Yonsei University Dental Hospital from the Behcet clinic of Severace Hospital after being diagnosed as Behcet's disease patients. 1. By Shimuzu's classification, possible type was the most numerous with 55.55% ; while suspected type was 19.76% ; incomplete type, 17,28% ; and complete type, 7.41% were observed in that order. The male to female ration was 1 to 1.61, and the average age of onset was 17.63 years. 2. Oral ulcers developed most frequently on the tongue (48.28%), and lip(23.15%), buccal mucosa (20.69%), palate\pharynx(4.43%), and gingiva(3.45%) also showed ulceration. 3. 38.27% of the patients were HSV positive : 27.16% were CRP positive ; 12.34% were ASO positive ; 9.87% were RF positive ; and 3.7% were ANA positive. 4. According to the answers to the survey, fatigue(85.18%) was most frequently associated with Behcet's diseage. Trauma by tooth brushing (22.22%), un specified reasons (20.98%), hard food chewing (12.35%), and irritation by dentition and/or prosthesis (13.58%) were observed in association with Behcet's disease. 23.46% had a history of tonsilitis. 5. Oral ulcers on the anterior part of tongue and buccal mucosa were associated with local irritatants. 6. Oral ulcers on the lip and posterior portion of tongue were not associated with local irritants. Local irritation by dentition and oral ulcer on the anterior part of tongue and buccal mucosa was observed to coexit with one another : in other words, lo9cal factors can act to cause of recurrence of an oral ulcer and to delay the healing process in Behcet's disease. Therefore, elimination of local factors along with systemic therapy must be recommended when treating oral ulcers.

  • PDF

A STUDY OF THE ANTI-ROTATING INNER POST SCREW SYSTEM AS A MEANS OF PREVENTING ABUTMENT SCREW LOOSENING (회전 방지용 Post Screw 시스템의 임플랜트 지대나사풀림 방지효과에 관한 연구)

  • Kim Jong-Hui;Lim Ju-Hwan;Cho In-Ho;Lee Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.671-683
    • /
    • 2005
  • Statement of problem: The most commonly reported problem associated with dental implant restoration is the loosening of the screws. Purpose: This study compared the efficacy of an implant system incorporating an anti-rotational locking sleeve(Anti-Rotating Inner Post Screw System(ARIPS-system)) with other, traditional implant systems as a means of minimizing vibration loosening. Materials and methods: Three implant systems were examined; the conventional external hex type, the ARIPS-system, and the internal taper type implant system 30 specimens(10 samples per group)were fabricated and each abutment screw was secured to the implant future with 32Ncm of torque force and loosening torque was measured using a Torque Gauge. The procedure was repeated 3 times, recording initial loosening torque each time. The re-tightened abutment screw was subjected to a cyclic load having a maximum forte of 200N and minimum of 20N at 2Hz over a period of 12,600 cycles. after which the loosening torque was measured. Measured values were calaulated for statistical analysis. Analysis of measured value was performed by 3 methods: (i) as a percentage average of the initial 3 loosening-torque values(initial loosening value) to the tightening torque of 32Ncm, (ii) as a percentage of the loosening torque value after a load of 200N(experimental value) to the initial loosening value, and (iii) as a percentage of the experimental value to the 32Ncm of tightening torque. The analyses shows the amount of initial loosening at the screw, loosening by repetitive load and the the final loosening value. Results: The results of this study were as follows (1) Percentage of initial loosening value to tightening-torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of external hex, ARIPS-system and internal taper. Value of internal taper showed significant difference with those of external hex and ARIPS-system (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). Conclusion: The results of the analysis of the final loosening level value, which are closely correlated to clinical use, show that the ARIPS-system can be a useful means of minimizing abutment screw loosening when compared to the external hex type system. Although further clinical studies need to be made, the ARIPS-system should be considered to maximize the long-term success of the implant prosthesis.

Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture (변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향)

  • Yun, Mi-Jung;Yoon, Min-Chul;Eom, Tae-Gwan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing.

A COMPARATIVE STUDY ON THE FRACTURE STRENGTH AND MARGINAL FITNESS OF FIBER-REINFORCED COMPOSITE BRIDGE (섬유강화형 복합레진브릿지의 파절강도 및 변연적합도에 관한 연구)

  • Choi Ho-Kuen;Shin Sang-Wan;Lim Ho-Nam;Suh Kuyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.526-546
    • /
    • 2001
  • Fiber-reinforced composite(FRC) was developed as a structural component for dental appliances such as prosthodontic framework. FRC provides the potential for fabrication of a metal-free, excellent esthetic prostheses. It has demonstrated success as a result of its simple fabrication, natural colour, and marginal integrity, and fracture resistance of veneering composite resin and the FRC material. Although it has lots of merits, clinical and objective data are insufficient. The purpose of this study was to evaluate the fracture strength and the marginal fitness of fiber reinforced composite bridge in the posterior region for clinical application. Sixteen bridges of each group. $Targis/Vectris^{(R)}$, $Sculpture-Fibrekor^{(R)}$, and In-Ceram, were fabricated. All specimens were cemented with Panavia 21 to the master dies. Strength evaluation was accomplished by a universal testing machine (Instron). The marginal fitness was measured by using the stereoscope (${\times}50$). The results were as follows. : 1. The fracture strength according to the materials was significantly decreased in order In-Ceram($238.81{\pm}82$), Targis Vectris($176.25{\pm}18.93$), Sculpture-Fibrekor($120.35{\pm}20.08$) bridges. 2. FRC resin bridges were not completely fractured, while In-Ceram bridges were completely fractured in the pontic joint. 3. The marginal accuracy was significantly decreased in order Targis/Vectris ($60.71{\mu}m$), Sculpture-Fibrekor($73.10{\mu}m$) In-ceram Bridge ($83.81{\mu}m$). 4. The fitness of occlusal sites had a lower value than the marginal sites(P<0.001), and the marginal gaps of inner site of the pontic were greater than that of outer sites of the pontic. Fiber reinforced composite bridges are new, esthetic prosthesis and can be clinically used in anterior regions and short span bridges. However, caution must be exercised when extrapolating laboratory data to the clinical situation because there are no long term clinical data regarding the overall success of the FRC.

  • PDF

Case Reports of Bone Grafting in Unilateral Alveolar-palatal Cleft Patients (편측성 치조. 구개 파열 환자에서 골 이식술의 치험레)

  • Bae, Yun-Ho;Park, Jae-Hyun;Lee, Myeong-Jin;Lee, Chang-Gon;Chin, Byung-Rho;Lee, Hee-Kyeung
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.198-205
    • /
    • 1991
  • We obtained successful functional and esthetic results by grafting of iliac marrow-cancellous bone in 2 cases of alveolar-palatal cleft patients. Bone graft of alveolar-palatal clefts provide bony support to adjacent teeth of cleft area, prevented from relapse of orthodontic arch expansion, closure of oroantral fistula and improvement of speech problem. 1. In one case, extraction of upper right central incisor that was little bone support, alignment of rotated teeth and expansion of collapsed arch segment were done with pre-ortodontic treatment. The other case, Bone grafting was done after removal of prosthesis with no preorthodontic treatment. 2. After mucoperiosteal incision in cleft area. The mucosal flap of labial area, palate and nose were separation and the raised nasal mucosa was sutured for closure of oroantral fistula. Then, the iliac marrow-cancellous bones were grafted to cleft site. 3. After 6 months of operation, we had seen the new bone deposition to cleft site in dental radiography and prosthetic treatments of missing teeth were done.

  • PDF

Optimized Implant treatment strategy based on a classification of extraction socket defect at anterior area (전치부에서 발치와 골결손부에 따른 최적의 심미를 얻을 수 있는 수술법)

  • Ban, Jae-Hyuk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2016
  • It is considered an implant failure when there is esthetic problems in the anterior area although the prosthesis function normally. In 2003, Dr. Kan et al stated that implant bone level is determined by the adjacent teeth. After that many scholars have studied how can achieve the esthetics result on adjacent teeth bone loss cases. In 2012, Dr. Takino published an article in Quintessence. He summarized previous articles and reclassified the defects from class 1 through 4. Class 1 and 2 depicts a situation where there is no bone loss on adjacent teeth. In Class 3 and 4, interproximal bone loss extends to the adjacent tooth. If one side is involved, it is Class 3. If both sides are involved, it is Class 4. The clue for esthetic implant restoration is whether bone loss extends to adjacent tooth or not. If the bone level of adjacent tooth is sound, we can easily achieve the esthetic but the bone level is not sound, the surgery will be complicated and the esthetic result will be unpredictable. So regenerative surgery for adjacent tooth is necessary for long-term maintenance. But the options and process were so complicated, the purpose of this article is to report the method simplify the surgery and gain a similar outcome.

Occlusal Adjustment and Prosthodontic Reconstruction on the Open-bite Patient. - Intentional Decrease of Occlusal Vertical Dimension - (자연치 교합조정에 의한 전치, 구치 개교합의 보철적 수복 - 수직고경의 의도적 감소증례)

  • Lee, Seung-Kyu;Kwon, Kung-Rock;Lee, Sung-Bok;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.133-147
    • /
    • 2000
  • A well-planned, precise occlusal adjustment of natural teeth has some distinct advantages over other forms of occlusal therapy. It should be emphasized, however, that an occlusal adjustment is an irreversible procedure and has definite contraindications in some mouths. Generally, the treatment methods for the patients that has open-bite will be following as below. : (1) Use of removable orthopedic repositioning appliance, (2) Orthodontics, (3) Full or partial reconstruction of the dentition, (4) Orthognathic surgical procedure, (5) Occlusal adjustment of the existing natural teeth, (6) Any combination of the above. Above all, the advantages of occlusal adjustment of natural teeth are : (1) the patient is more able to adapt to the changes in jaw position and posture; (2) the phonetic or speaking ability of the patient is not significantly changed and usually is improved; (3) the esthetics of the natural teeth is not altered and often is better; (4) the hygiene of the individual teeth is easily maintained; and (5) the functional usage of the teeth as cutting and chewing devices is markedly improved. The objective of an occlusal adjustment, as with any form of occlusal therapy, is to correct or remove the occlusal interferences, or premature contacts, on the occluding parts of the teeth which prevent a centric relation closure of the mandible. A systematic, disciplined approach can be followed in treatment, the objectives should be listed. They are : (1) Centric relation occlusion of the posterior teeth. (2) Proper "coupling" of the anterior teeth. (3) An acceptable disclusive angle of the anterior teeth in harmony with the condylar movement patterns. (4) Stability of the corrected occlusion. (5) Resolution of the related symptoms. For the patient with open-bite on anterior and posterior teeth, this case report shows the treatment methods in combination the fixed prosthesis with the selective cutting of the natural teeth. Occlusal adjustment is no longer an elective procedure but a mandatory one for patients requiring restorations and those in treatment for TMD dysfunctions or those whose dentitions show signs of occlusal trauma. Occlusal adjustment is essential for all who do not display the above lists.

  • PDF

Evaluation of Tightness of Proximal tooth Contact on Implant Prostheses (임프란트 보철수복물에서의 인접치간 접촉강도의 평가)

  • Kim, Sang-Pil;Jung, J-Hyun;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.371-379
    • /
    • 2008
  • The aim of this study was to evaluate the tightness of proximal tooth contact(TPTC) using a novel device at rest state on implant prostheses. Ten healthy young adults with class I normal occlusion consented to participate in the study and twenty patients were restored with a total 20 single-implant crowns in the left maxillary and mandibular second molars for 10 single-implant crowns, respectively. Test area were divided by 4 groups. UM describes the contact between the upper natural left first molar and natural second molar; LM the contact between the lower natural left first molar and natural second molar; IUM the contact between the upper natural left first molar and implant second molar and ILM the contact between the lower natural left first molar and implant second molar. The TPTC was measured at rest state in each area. The mean TPTC of the UM, LM, IUM and ILM was 1.48(${\pm}0.44$) N, 1.78(${\pm}0.40$) N, 1.14(${\pm}0.37$) N and 1.30(${\pm}0.32$) N respectively. These results indicate that the TPTC was less between natural tooth and implant prosthesis than between natural teeth.