The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings  

Lee, Jee-Hyuk (Department of Prosthodontics, College of Dentistry, Dankook University)
Choi, Yu-Sung (Department of Prosthodontics, College of Dentistry, Dankook University)
Cho, In-Ho (Department of Prosthodontics, College of Dentistry, Dankook University)
Publication Information
Journal of Dental Rehabilitation and Applied Science / v.26, no.4, 2010 , pp. 433-445 More about this Journal
Abstract
The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).
Keywords
accuracy; impression copings; impression trays; splinting;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Craig. RG. Restorative dental materials. St.Louis CV Mosby CO. 1989. p.293-346.
2 Phillips RW. Skinner's Science of Dental Materials. 8th ed., WB Saunders Co., Philadelphia, 1982. p.137- 156.
3 Eames WB, Sieweke JC, Wallace SW et al. Elastomeric impression materials : Effect of bulk on accuracy. J Prosthet Dent 1979;41:304-7.   DOI   ScienceOn
4 Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implant in the edentulous jaw: a study of treatment from the time of prostheses placement to the first annual check up. Int J Oral Maxillofac Implants 1991;6:270-6.
5 Kan JY, Rungcharassaeng K, Bohsali K et al. Clinical methods for evaluation implant framework fit. J Prosthet Dent 1999;81:7-13.   DOI   ScienceOn
6 Tan KB, Rubenstein JE, Nicholls JI et al. Threedimensional analysis of the casting accuracy of one piece, osseointegrated implant retained prostheses. Int J Prosthodont 1993;6:346-63.
7 Iturregui JA, Aquilino SA, Ryther JS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 1993;69:503-9.   DOI   ScienceOn
8 Vigolo P, Fonzi F, Majzoub Z et al. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 2004;92:470-6.   DOI   ScienceOn
9 Naconecy MM, Teixeira ER, Shinkai RS et al. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19: 192-8.
10 Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004;13:358-66.   DOI
11 Cho GC, Chee WW. Distortion of disposable plastic stock trays when used with putty vinyl polysiloxane impression materials. J Prosthet Dent 2004;92:354-8.   DOI   ScienceOn
12 Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007;16:187-94.   DOI   ScienceOn
13 Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000;83:323-31.   DOI   ScienceOn
14 Liou AD, Nicholls JI, Yuodelils R et al. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. Int J Prosthodont 1993;6:377-83.
15 Brunski JB, Hipp JA. In vivo forces on endosteal implants: a measurement system and biomechanical considerations. J Prosthet Dent 1984;51:82-90.   DOI   ScienceOn
16 Boggan RS, Strong JT, Misch CE et al. Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants. J Prosthet Dent 1999;82:436-40.   DOI   ScienceOn
17 Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-7.   DOI   ScienceOn
18 White GE. Osseointegrated dental technology. London: Quintessence, 1993:82-3.
19 Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-60.
20 Binon PP, McHugh MJ. The effect of eliminating implant/abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-9.
21 Branemark PI, Albrektsson T, Zarb GA. Tissueintegrated prostheses: Osseointegration in clinical dentistry. Chicago: Quintessence; 1985. p.253-7.
22 Assif D, Fenton A, Zarb G. Comparative accuracy of implant impression procedures. Int J Periodontics & Restorative Dentistry 1992;12:112-121.
23 HeeJe L, Joseph SS, Hochstedler JL. The accuracy of implant impressions: A systematic review. J Prosthet Dent 2008;100:285-91.   DOI   ScienceOn
24 Reisbick MH, Matyas J. The accuracy of highly filled elastomeric impression materials. J Prosthet Dent 1975;33:67-72.   DOI
25 Burton JF, Hood JA, Plunkett DJ et al. The effects of disposable and custom-made impression trays on the accuracy of impressions. J Dent 1989;17:121-3.   DOI   ScienceOn
26 Bomberg TJ, Hatch RA, Hoffman W. Impression material thickness in stock and custom tray. J Prosthet Dent 1985;54:170-2.   DOI   ScienceOn
27 Burns J, Palmer R, Howe L et al. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 2003;89:250-5.   DOI   ScienceOn
28 Jemt T, Rubenstein JE, Carlsson L et al. Measuring fit at the implant prosthodontic interface. J Prosthet Dent 1996;75:314-25.   DOI   ScienceOn
29 Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-8.   DOI   ScienceOn
30 Becker W, Becker BE, Newman MG et al. Clinical and microbiologic findings that may contribute to dental implant failure. Int J Oral Maxillofac Implants 1990;5:31-8.
31 Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-5.   DOI   ScienceOn
32 Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996;11:216-22.
33 Carr AB. A Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-55.
34 Barrett MG, de Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993;2:75-82.   DOI   ScienceOn
35 Tolman DE, Laney WR. Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 1992;7:477-84.
36 Adell R, Lekholm U, Rockler B. A 15-year study of osseo-integrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.   DOI
37 Phillips KM, Nicholls JI, Ma T et al. The accuracy of three implant impression technique. A three dimensional analysis. Int J Oral Maxillofac Implants 1994;9:533-40.
38 Naconecy MM, Teixeira ER Shikai RS. Evaluation of the accuracy of 3 transfer techniques for implantsupported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19:192-8.