• 제목/요약/키워드: Dental internal fit

검색결과 68건 처리시간 0.021초

적층 가공방식에 따른 고정성 치과보철물의 변연 및 내면 적합도 평가연구 (Evaluation the clinical acceptability of the marginal and internal gaps of fixed partial denture fabricated with additive manufacturing technology)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제40권4호
    • /
    • pp.209-215
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical acceptability of the marginal and internal gap of Co-Cr metal copings fabricated with stereolithography (SLA). Methods: Titanium master dies were milled after scanning of the prepared tooth (n=30). For group I, Co-Cr metal copings were made from conventional lost-wax technique(LWT, n=10). For group II, the master dies were scanned and designed with CAD system. Then, metal copings were milled with Co-Cr(SUB, n=10). For group III(ADD, n=10), the scanning and design procedures were same as group II and burn-out resins were fabricated with SLA device. The marginal and internal discrepancies were measured under an optical microscope(100x) on ten reference points and were statistically analyzed with one-way ANOVA(${\alpha}=.05$). Results: The mean total discrepancies were $53.76{\pm}12.42{\mu}m$ in the LWT group and $69.82{\pm}15.48{\mu}m$ in the ADD group. The SUB group showed the largest total mean value $110.33{\pm}13.77{\mu}m$. There was statistically significant difference between the SUB and the other groups(P<0.05). Conclusion : Co-Cr metal copings fabricated with SLA technology showed clinically acceptable value on marginal and internal gap and there was no statistically significant difference between conventional lost-wax technique and SLA.

3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석 (Marginal and internal fit of interim crowns fabricated with 3D printing and milling method)

  • 손영탁;손큰바다;이규복
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.254-261
    • /
    • 2020
  • 목적: 본 연구의 목적은 서로 다른 제작 방법인 절삭 가공과 적층 가공 기술로 제작된 임시 보철물의 변연 및 내면 적합도를 평가하는 것이다. 연구 재료 및 방법: 상악 우측 제1대구치를 도재 수복을 위한 지대치 모형으로 준비하였다. 석고를 이용하여 총 40개의 실험 모형으로 복제하였고, 각각의 실험 모형을 구강 스캐너를 사용하여 스캔 데이터를 획득하였다. 3종의 3D 프린터(Meg-printer 2; Megagen, Zenith U; Dentis 그리고 Zenith D; Dentis) 및 1종의 밀링 장비(imes-icore 450i; imes-icore GmbH)를 사용하여 각 그룹당 10개의 임시 보철물을 제작하였다. 임시 보철물의 내면에 실리콘을 채우고 모형에 적합하여 중합이 완료된 후, 실리콘으로 내면이 복제되어 있는 실험 모형을 구강 스캐너를 사용하여 스캔 데이터를 획득하였다. 3차원 검사 소프트웨어(Geomagic control X; 3D Systems)를 이용하여 변연 간격, 절대 변연 간격, 섐퍼, 축벽, 교두, 교합 영역의 적합도를 분석하였다. 통계 분석은 제작 방법의 차이를 비교하기 위해서 Kruskal-Wallis test를 사용하여 검증하였으며, 사후 검정을 위해서 Mann-Whitney U-test and Bonferroni correction method을 사용하였다(α = 0.05). 결과: 3종의 3D 프린터와 1종의 밀링 장비에서 제작된 임시 보철물의 절대 변연 간격은 유의한 차이를 보이지 않았다(P = 0.812). 축벽, 교합 간격에서 밀링 장비와 3D 프린터 사이에 유의한 차이를 보였다(P < 0.001). 결론: 3종의 3D 프린터로 제작된 임시 보철물의 변연 적합도는 모두 임상적 허용 범위(< 120 ㎛)에 있었으므로, 적합도 측면에서 본다면 임시 보철물 제작을 위해서 충분히 사용될 수 있다.

여러 가지 Die spacing material의 물리적 성질에 대한 연구 (A STUDY ON THE PHYSICAL CHARACTERISTICS OF THE THREE COMMONLY USED DIE SPACING MATERIALS)

  • 문홍석;김종진
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.640-650
    • /
    • 1999
  • As an optimal quality of the restorations, there should be a least amount of seating discrepancy between the casting and abutment teeth. However, high viscosity of the cementing medium and its resulting thickness may prevent complete seating of the restoration. The use of die spacing material provides adequate internal relief for the cementing medium. The purpose of this study is to compare the thickness of three commonly used die spacing materials. Materials and Methods: Stone plates were fabricated and divided into 12 sections to be painted with die spacers. Tru-Fit, Whip-Mix and Belle do St. Claire die spacer which are commonly used in dental practice were tested in this study. Each die spacers were painted layer by layer according to the manufacturer's recommendation. The average thickness of each die spacers were measured with light microscope(${\times}100$) and compared between them. Results and Conclusions. A silver-colored Tru-Fit die spacer has the lowest value of thickness without statistical significance comparing with a gold-colored Tru-Fit die spacer and a gray layer of Whip-Mix die spacer has the highest value of thickness without any statistical significance comparing with Belle de St. Claire die spacer. Three and four layers of Tru-Fit die spacer and two layers of Whip-Mix and Belle de St. Claire die spacers seem to be in the acceptable range of thickness of 25 to $45{\mu}m$ for optimal seating of the restorations. The standard experimental design and method should be fur thor evaluated for more consistent and objective results.

  • PDF

디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가 (Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer)

  • 이범일;유승규;유승민;김지환
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.334-340
    • /
    • 2020
  • Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann-Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 ㎛ as compared to the 10-minute rinsing group (67.52±0.92 ㎛) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.

Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

  • Sen, Nazmiye;Sermet, Ibrahim Bulent;Gurler, Nezahat
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2019
  • PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with $0.7{\mu}L$ of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in ${\mu}m$) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

유한요소법을 이용한 치아 임플랜트 피로수명 예측 (FATIGUE LIFE ESTIMATION OF IMPLANT USING A FINITE ELEMENT METHOD)

  • 한인숙;손정훈;양영수;이승영
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.414-420
    • /
    • 2006
  • Purpose : The purpose of this study is to use finite element analysis to predict the fatigue life of an implant system subjected to fatigue load by mastication (chewing force). The reliability and the stability of implant system can be defined in terms of the fatigue strength. Not only an implant is expensive but also it is almost impossible to correct after it is inserted. From a bio-engineering standpoint, the fatigue strength of the dental implant system must be evaluated by simulation (FEA). Material and Methods Finite element analysis and fatigue test are performed to estimate the fatigue strength of the implant system. Mesh of implant is generated with the actual shape and size. In this paper, the fatigue strength of implant system is estimated. U-fit (T. Strong, Korea, internal type). The stress field in implant is calculated by elastic-plastic finite element analysis. The equivalent fatigue stress, considering the contact and preload stretching of a screw by torque for tightening an abutment, is obtained by means of Sine's method. To evaluate the reliability of the calculated fatigue strength, fatigue test is performed. Results: A comparison of the calculated fatigue strength with experimental data showed the validity and accuracy of the proposed method. The initiation points of the fatigue failure in the implant system exist in the region of high equivalent fatigue stress values. Conclusion: The above proposed method for fatigue life estimation tan be applied to other configurations of the differently designed and improved implant. In order to prove reliability of prototype implant, fatigue test should be executed. The proposed method is economical for the prediction of fatigue life because fatigue testing, which is time consuming and precision-dependent, is not required.

서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성 (Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods)

  • 조영범;정재헌;김희중
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.366-376
    • /
    • 2013
  • 구강내 스캔(Group 1), 모델 광학 스캔(Group 2)과 모델 접촉식 스캔(Group 3)방식으로 각각 zirconia 코핑을 제작하여 광학 현미경으로 적합성을 관찰하였다. 측정항목은 변연오차(absolute marginal discrepancy;AMD), 변연간극(marginal gap; MG), 측방간격(gap of axial wall; GA), 선각간격(gap of line angle; GL)와 교합간격(gap of occusal surface; GO)이었으며, 결과는 아래와 같았다. 1. Group 1, Group 2, Group 3의 평균 AMD는 각 각 $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$이고, Group1, Group 2, Group 3의 MG는 각 각 $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$였다. AMD와 MG는 각 그룹에서 통계학적으로 유의한 차이를 보여주지 않았다(Anova test, P>0.05). 2. Group 2의 GA가 Group 1과 Group 3에 비해 통계학적으로 유의하게 적은 수치를 나타내었다(Anova test, P<0.05). 3. Group 1의 GL과 GO가 다른 그룹에 비해 통계학적으로 높은 수치를 나타내었다(Mann-whitney test(P<0.05). 세 가지 스캔 방식으로 제작된 zirconia 코핑은 세라믹 보철의 가장 중요한 평가 요소인 AMD와 MG에서 서로 통계학적 차이를 보이지 않았다.

한국어판 치과위생사의 직무만족 측정도구의 타당도와 신뢰도 (Validity and Reliability of the Korean Version of Dental Hygienist Satisfaction Survey)

  • 임순연;박지현
    • 융합정보논문지
    • /
    • 제9권9호
    • /
    • pp.219-228
    • /
    • 2019
  • 본 연구는 직무만족 측정도구를 국내 실정에 맞게 수정하여 치과위생사의 직무만족을 평가 할 수 있는 도구를 개발하고 타당도와 신뢰도를 평가하고자 시행하였다. 직무만족 원도구의 54문항을 번역하여 내용타당도와 내용분석을 통해 총 35문항을 삭제하여 총 24문항으로 확정되었다. 연구결과 탐색적 요인분석에 의해 전반적인 만족, 소득, 환자관계, 직업적 시간, 개인시간, 실무관리, 진료활동, 동료관계로 구분되었다. 확인적 요인분석을 통한 모형의 적합도는 대체로 기준에 충족하였다. 내적 일관성을 검증한 결과 Cronbach's ${\alpha}$은 전반적인 만족 0.918, 소득 0.833, 환자관계 0.804, 직업적 시간 0.675, 개인시간 0.939, 실무관리 0.739, 진료활동 0.757, 동료관계 0.742로 나타나 신뢰할 만한 수준의 측정도구임을 나타냈다. 이상의 결과에 따라 치과위생사의 직무만족 측정도구의 타당도와 신뢰도는 적합하다고 검증되었다. 향후 치과위생사의 직무만족 연구에 사용될 수 있을 것으로 생각된다.

다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구 (Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods)

  • 정승진;조혜원;정지혜;김정미;김유리
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.211-218
    • /
    • 2019
  • 목적: 본 연구에서는 CAD/CAM 기술로 제작한 4가지 금속하부구조물의 변연 및 내면 적합도를 비교하여 정확도 및 임상적 효용성을 알아보고자 한다. 재료 및 방법: 상악 중절치 레진모형치아를 삭제한 뒤 복제하여 Ni-Cr 합금 표준 모형을 제작하였다. 이를 공초점 현미경방식의 구강 스캐너를 이용해 12개의 STL 파일을 얻었다. CAD 프로그램 상에서 $50{\mu}m$의 시멘트 공간을 부여한 두께 0.5 mm의 금속하부구조물을 디자인하였다. Co-Cr 금속하부구조물은 다음 4가지 방법으로 제작하였다: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). 변연 및 내면 적합도를 측정하기 위해 실리콘 복제법을 이용하였다. 측정한 결과값은 SPSS 통계 프로그램을 이용하여 일원배치분산분석(one-way ANOVA)으로 통계처리하고, 사후검정으로 Scheffe test를 시행하였으며, 5% 유의수준으로 평가하였다(${\alpha}=.05$). 결과: 변연 적합도는 WM군($27.66{\pm}9.85{\mu}m$)과 MS군($28.88{\pm}10.13{\mu}m$)이 RP군($38.09{\pm}11.14{\mu}m$)에 비해 통계적으로 유의하게 작았다. 치경부 적합도는 MS군이 RP군에 비해 통계적으로 유의하게 작았다. 축면 적합도는 WM군과 MS군이 RP군과 SLM군 보다 통계적으로 유의하게 작았다. 절단면 적합도는 RP군이 통계적으로 유의하게 작았다. 결론: Wax pattern milling & Casting, Milling & Sintering법으로 제작한 Co-Cr coping의 변연과 축면에서의 적합도가 더 우수하였다. 모든 군의 Co-Cr coping의 변연, 치경부, 축면 적합도는 임상적으로 허용할만한 범위 안에 있었다.

단일구조 지르코니아 크라운의 소결 후 추가 소성 과정이 변연 및 내면 적합도에 미치는 영향 (Effect of additional firing process after sintering of monolithic zirconia crown on marginal and internal fitness)

  • 신미선;이현종
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.321-327
    • /
    • 2019
  • 목적: 본 연구는 단일구조 지르코니아 크라운의 소결 후 소성 과정이 변연 및 내면 적합도에 미치는 영향에 대하여 3차원으로 평가해 보고자 하였다. 재료 및 방법: 타이타늄 지대치 모형을 제작하여 10개의 단일구조 지르코니아 크라운을 제작하였다. 제작된 단일구조 지르코니아 크라운을 소결 한 상태를 대조군으로, 소결 후 광택을 위해 추가적인 소성단계를 거친 후를 실험군으로 설정하였다. 각 군에서 triple-scan protocol을 이용하여 협설과 근원심으로 단면을 형성하고 변연 및 내면 적합도를 계측하여 통계 분석하였으며, 삼차원 표면 비교를 시행하였다 (${\alpha}=.05$). 결과: 변연과 내면 적합도를 분석한 결과 근심 축벽에서 대조군($32.0{\pm}24.3{\mu}m$)과 실험군 간($17.0{\pm}10.8{\mu}m$)의 통계적 유의한 차이가 있었고 (P < .020), 원심 축벽에서 대조군($60.2{\pm}24.3{\mu}m$)과 실험군($71.8{\pm}21.5{\mu}m$)간의 통계적으로 유의한 차이가 있었다 (P < .01). 나머지 측점지점에서는 통계적으로 유의한 차이가 없었다. 결론: 단일구조 지르코니아 크라운에서의 소결 후 추가적인 소성은 내면의 변형에 큰 영향을 미치지 않았고 임상적으로 허용 가능한 범위에 있었다.