• Title/Summary/Keyword: Dental impression material

Search Result 96, Processing Time 0.026 seconds

Effects of Silicone Polymer Blends on Physical Properties of Dental Polyvinylsiloxane Impression Materials (실리콘폴리머의 혼합사용이 폴리비닐실록산 치과용 인상재의 물성에 미치는 영향)

  • Lim, Chang-Ha;Kim, Min-Kang;Kim, Young-Chul;Park, Nam-Cook;Song, Ho-Jun;Park, Yeong-Joon
    • Elastomers and Composites
    • /
    • v.44 no.1
    • /
    • pp.76-83
    • /
    • 2009
  • The purpose of this study was to investigate the effects of combined use of several types of silicone polymers on the physical properties of the dental polyvinylsiloxane impression materials (PVS). Four types of silicone prepolymers having different molecular weight and vinyl group position, and two types of cross-linkers having differently located silyl hydride functional groups were used in various combinations for the formulation. The samples containing bimodal or trimodal prepolymers showed higher tensile strength, elongation at break, and elastic deformation than those containing only one type of prepolymer. The samples using CR210 cross-linker which has side- and terminal-silyl hydride groups showed higher elastic deformation and elongation at break than those using CR101 cross-liker which has side-only silyl hydride group. High vinyl content prepolymer having side vinyl group delayed setting even though it enhanced tensile strength. Further studies are needed to clarify the specific role of this component on setting time and to find appropriate controlling methods for making improved PVS with optimum workability.

A Study on Remake of Dental Prosthesis According to Dental Laboratory Characteristics (Focusing on Daegu and Gyeong-buk of Dental lab) (치과기공소의 특성에 따른 치과보철물의 재제작에 관한 연구 - 대구.경북 치과기공소 중심으로 -)

  • Kim, Jeong-Sook;Lee, Hee-Sung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.227-236
    • /
    • 2011
  • Purpose: The purpose of this study was to reduce the remake rate of dental prosthesis. We examined remake cause and major factor of dental prosthesis to determine methods for raising dental prosthesis satisfaction. Methods: Subjects included dental technicians in the metropolitan areas of the cities of Daegu and Gyeong-buk. Surveys were filled out by consenting dental technicians. Statistical analysis was done using SPSS version 19.0 for Windows. We determined frequencies and percentage, calculating means, and standard deviations, and determining statistical significance using t-tests, analysis of variance. Results: Impression or material transform is high among remake cause and margin is high among remake major factor. Crown class showed differences in General characteristics associated with age, number of employees, and number of connection dental. Porcelain class showed differences in General characteristics associated with age, number of employees, and number of connection dental. Denture class showed differences in General characteristics associated with age, monthly salaray, and career. Implant class showed differences in General characteristics associated with age, education, and career. Conclusion: In order to reduce remake rate of dental prosthesis, communication of dentist, dental technician, and the patient are require and correct information of patient and dental prosthesis are need.

Microsurgical Approach for Root Coverage of Receding Gingiva in the Esthetic Zone

  • Mohan, Ranjana;Jain, Rohit
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.2
    • /
    • pp.69-73
    • /
    • 2013
  • Facial esthetics and smiling are key components in nonverbal communication and have an important role in determination of the first impression of a person. The various components of the smile in dental esthetics include Gingival scaffold, lip framework, and Teeth. The periodontist creates a smile by performing various periodontal plastic microsurgery procedures for management of mucogingival problems. A 25-year-old patient reported to the Department of Periodontology at Teerthanker Mahaveer Dental College and Research Center, Moradabad, Northern India, with the chief complaint of long looking teeth in the upper jaw, making him conscious while smiling. Miller class I gingival recession with Maxillary left canine (23) was diagnosed. Periodontal plastic microsurgery employing double papilla grafting with connective tissue graft harvested from the palate in order to cover denuded root was performed using microsurgical instruments and microsuturing with 6-0 suturing material under magnification. Healing was uneventful, with achievement of 100% root coverage of denuded root after three months. The patient was highly impressed and satisfied with his enhanced smile.

  • PDF

Application of Various Types of Surfactants for Improving Hydrophilic Properties of Polyvinylsiloxane Dental Rubber Impression Materials and its Effects on Physical Properties (폴리비닐실록산 치과용 고무인상재의 친수성 향상을 위한 계면활성제의 응용과 물성에 미치 는 영향)

  • Park, Yeong-Joon;Hwang, Moon-Jin;Kim, Min-Kang;Song, Ho-Jun;Ha, Kwang;Kang, Shin-Young
    • Elastomers and Composites
    • /
    • v.43 no.2
    • /
    • pp.88-103
    • /
    • 2008
  • This study was purposed to investigate the effects of surfactants and fillers on physical properties of hydrophilic polyvinylsiloxane dental impression materials (PVS). Incorporation of surfactants enhanced the hydrophilicity of the PVS, however, it induced increased viscosity and permanent deformation ratio, delayed setting, and decreased tensile strength. At high concentrations of surfactant, the tensile strength was observed to decrease significantly due to the internal pore formation. Especially, the hydrophilicity of the PVS was significantly enhanced with the addition of Silwet L-77. However, the viscosity, strain in compression, pore formation, and setting time increased whereas the elastic recovery rate and strength remarkably decreased. The PVS dental materials containing Span 20 showed the lowest degree of viscosity increase, delayed setting, pore formation, and hydrophilicity. The delayed setting, pore formation, and strength decrease caused by the incorporation of surfactant were improved by substituting the crystalline quartz filler with diatomaceous earth while the contact angle of PVS dental materials increased.

AGAR-ALGINATE COMBINED IMPRESSION TECHNIQUE AND DIMENSIONAL CHANGE RESULTING FROM IDOPHOR DISINFECTION (아기-알지네이트 연합 인상체의 보관방법 및 idophor 침적소독에 의한 체적 변화에 관한 연구)

  • Oh Nam-Sik;Seo Joung-Min;Kim Sun-Hee;Youn Young-Ah;Shim Joon-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Statement of problem : Because dental impression can be a cross-infection source, disinfection, such as immersion disinfection is nessecary. However, the disinfection process may change the volume of the impression cast. Purpose : The purpose of this study is to find out the effects on dimensional change of different storage times and methods, of agar-alginate impression when immersed in a 5% idophor disinfectant. Material and Methods : An agar-alginate impression was made from a mandible model and then was disinfected and stored according the experimental conditions and a stone model was produced. Measurements were taken between reference points on the original mandible model and they were compared to measurements taken between reference points on the stone model. The study was divided into 4 groups. In group 1, the impression was stored in a 100% humidor for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours and 24 hours and stone models were made at each time. In group 2, the impression was immersed in 5% idophor disinfectant and then stored in a 100% humidor for the same length of times as group 1, and stone models were made at each time. In group 3, the impression was stored in extend-A-pourR, a special storage solution for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours, 24 hours 3 days, and 7 days and stone models were made at each time. In group 4, the impression was immersed in 5% idophor disinfectant and then stored in stored in extend-A-pourR, a special storage solution for the same length of times as group 3, and stone models were made at each time. 5 impressions and stone models were made at each time to make a total of 180. The Student-t test (P < .05) was used to do a statistical analysis of the measurements of the mandible model and stone models. The repeated-measure 2-way analysis of variance (P < .05) was used to do a statistical analysis of the difference in the 4 groups. Results : The percent liner dimensional change was from $0.25{\pm}0.03%$ (group 1, 30 minutes) to $0.34{\pm}0.06%$ (group 4, 7 days). No significant change was noticed between the 4 groups. Conclusion : According to the above study, in both methods, least dimensional change was recorded when the storage times were short and in both methods, immersion in 5% idophor disinfectant did not effect dimensional change in the agar-alginate impression.

Manufacturing of metal-framework for maxillary removable partial dentures using milling wax-blocks (Wax-block milling을 이용한 상악 가철성 국소의치 금속구조물 제작 증례)

  • Seo, A-Ra;Kwon, Soon-Suk
    • Journal of Technologic Dentistry
    • /
    • v.44 no.1
    • /
    • pp.24-30
    • /
    • 2022
  • This research introduces the manufacturing process of the metal-framework of one of the maxillary partial dentures, the "obturator", using milling wax-blocks, for patients with palate loss due to oral cancer. It explains the protocol of taking the patient's oral impression, preparation of a working cast, scanning, designing using a computer-aided design program, investing the milling wax-blocks, and completing the obturator. This method does not follow the traditional wax and agar process thereby reducing the errors arising during the manufacturing process and decreasing the time, material, and labor required. Moreover, the retention, stability, and compatibility of the metal framework were observed to be high in both the working cast and oral cavity.

A Study on the Physical Properties of Addition Silicone Impression Materials (부가중합형실리콘인상재의 물리적 특성에 대한 연구)

  • Kim, Soo-Hwa
    • Journal of dental hygiene science
    • /
    • v.6 no.4
    • /
    • pp.231-235
    • /
    • 2006
  • This study evaluated the properties of polyvinylsiloxane impression materials: Strain-in-compression, Elastic recovery, Consistency, and Wettability. Four polyvinylsiloxane impression materials(Examixfine, GC, Japan; Aquasilultra, Dentsply, USA; Extrude, Kerr, USA; Perfect-F, Handae, Korea) were used in this study. The measured data were analyzed with SPSSWIN 12.0 program. The results were as follows : 1. The strain-in-compression values showed that Extrude had the lowest value, 4.86% and Examixfine had the highest value, 6.78%. Significant difference between Examixfine and Perfect-F was not found but the other groups had significant differences(p = 0.000). 2. In the elastic recovery test, Extrude had the highest, 99.83% and Perfect-F had the lowest, 96.54%. There is no significant difference between Examixfine and Aquasilultra. The other impression material groups showed significant differences(p = 0.000). 3. The measurement of consistency results that the diameter of Examixfine was the largest, 45.12mm and one of Perfect-F was the smallest, 40.28 mm. No differences were shown between Examixfine and Aquasilultra and between Extrude and Perfect-F(p = 0.001). 4. Aquasilultra had a better hydrophilicity($47.85^{\circ}$) than other materials. Perfect-F had a larger contact angle($94.89^{\circ}$) and was hydrophobic. There were significant differences between groups(p = 0.000). 5. As for correlation among the test types, contact angle correlated with strain-in-compression, elstic recovery and consistency. The strain-in-compression had correlation to contact angle and elastic recovery. The elastic recovery correlated with contact angle and strain-in-compression. And the consistency had correlation to contact angle.

  • PDF

Dimensional stability of rubber impression materials immersed in iodophor disinfectant (요오드 소독제에 침전된 고무인상재의 체적안정성)

  • Choi, Mee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Purpose: The purpose of this study was to determine the dimensional stability of three rubber impression materials (polysulfide, polyvinylsiloxane, polyether) in an iodophor disinfectant. Materials and Methods: Seventy-two impressions were made with each material and divided into control, 10-minute, and 30-minute immersion groups using an iodophor as the disinfectant. A microscope was used to measure dimensional changes in the stone casts made from each group of impressions, and the percent change was analyzed using a two-way ANOVA (P = 0.05). Results: All dimensional changes after iodophor disinfection were small in 10 minute groups, however, showed significantly increased in 30 minute groups (P < 0.05). Conclusion: Clinically, it can be recommended to use iodophor disinfectant for rubber materials within 10 minute.

Fabrication of complete dentures made with monolithic discs through CAD/CAM using facial scan data and individual tray duplicating temporary denture: a case report (안면스캔 데이터와 임시의치를 복제한 개인 트레이를 활용하여 CAD/CAM을 통한 monolithic disc로 제작한 총의치 수복: 증례 보고)

  • Ju Hyun Kim;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.158-167
    • /
    • 2023
  • As digital technology has advanced in the field of dentistry, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) has brought changes to the stages of dental treatment. The use of CAD/CAM technology in dental restoration offers clinical efficiency and convenience by reducing production time and appointment intervals, while also simplifying the fabrication process to reduce errors. In this case, digital replication and printing of temporary teeth were used to aid a patient with complex medical histories and physical disabilities. The final impression obtained with silicone impression material included information on the vertical dimension, centric relation, and the angle and length of the anterior teeth, which shortened the production time and appointment intervals and increased patient satisfaction. The final restoration was fabricated using milling and monolithic disc techniques, demonstrating appropriate stability, retention, and support, resulting in functional and aesthetic satisfaction.

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.