• Title/Summary/Keyword: Dental Patients

Search Result 4,481, Processing Time 0.036 seconds

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

Diagnosis and Effect of Maxillary Expansion in Pediatric Sleep-Disordered Breathing (소아 수면호흡장애의 진단과 상악확장술의 치료효과)

  • Kim, Doyoung;Baek, Kyounghee;Lee, Daewoo;Kim, Jaegon;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.369-381
    • /
    • 2019
  • The aim of this study was to analyze the changes and improvements in symptoms of sleep-disordered breathing (SDB) using semi-rapid maxillary expansion (SRME) in children with narrow maxilla and SDB symptoms. Subjects were 15 patients with sleep disorder (apnea-hypopnea index, AHI ≥ 1) and narrow maxillary arch between 7 and 9 years of age. Before the SRME was applied, all subjects underwent pediatric sleep questionnaires (PSQ), lateral cephalometry, and portable sleep monitoring before expansion (T0). All subjects were treated with SRME for 2 months, followed by maintenance for the next 3 months. All subjects had undergone PSQ, lateral cephalometry, and portable sleep monitoring after expansion (T1). Adenoidal-nasopharyngeal ratio (ANR), upper airway width and hyoid bone position were measured by lateral cephalometry. The data before and after SRME were statistically analyzed with frequency analysis and Wilcoxon signed rank test. As reported by PSQ, the total PSQ scale was declined significantly from 0.45 (T0) to 0.18 (T1) (p = 0.001). Particularly, snoring, breathing, and inattention hyperactivity were significantly improved (p = 0.001). ANR significantly decreased from 0.63 (T0) to 0.51 (T1) (p = 0.003). After maxillary expansion, only palatopharyngeal airway width was significantly increased (p = 0.035). There was no statistically significant difference in position of hyoid bone after expansion (p = 0.333). From analysis of portable sleep monitoring, changes in sleep characteristics showed a statistically significant decrease in AHI and ODI, and the lowest oxygen desaturation was significantly increased after SRME (p = 0.001, 0.004, 0.023). In conclusion, early diagnosis with questionnaires and portable sleep monitoring is important. Treatment using SRME will improve breathing of children with SDB.

Histomorphometric Study of Sinus Bone Graft using Various Graft Material (다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가)

  • Lee, Ji-Young;Kim, Young-Kyun;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • The aim of this study was to evaluate histomorphometrically and compare the efficiency of various bone graft material and autogenous tooth bone graft material which were used in sinus bone graft procedure. Subjects were the 24 patients who had treated with sinus bone graft using lateral approach from October 2007 to September 2009 at SNUBH. The average age was $52.51{\pm}11.86$ years. All cases was taken after 4month of procedure and divided into 3 groups according to bone graft material. Group 1: autogenous tooth bone graft material, Group 2: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), group 3: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). Total 37 implant placement area were included and evaluated(7 in group 1, 10 in group 2, 20 in group 3). Evaluation of new bone formation, ratio of woven bone to lamellar bone, ratio of new bone to graft material were performed on each tissue section. Kruskal-Wallis test was used for statistical analysis(SPSS Ver. 12.0, USA). New bone formation were $52.5{\pm}10.7%$ in group 1, $52.0{\pm}23.4%$ in group 2, $51.0{\pm}18.3%$ in group 3. There were no statistical significant differences between each groups. Ratio of woven bone to lamella bone were $82.8{\pm}15.3%$ in group 1, $36.7{\pm}59.3%$ in group 2, $31.0{\pm} 51.2%$ in group 3. Ratio of new bone to graft material were $81.3{\pm}10.4%$ in group 1, $72.5{\pm}28.8%$ in group 2, $80.3{\pm}24.0%$ in group 3. After 4 month of healing period, all group showed favorable new bone formation and around graft material and implant. Within limitation of our study, it is suggested that autogenous tooth bone graft material might be used as novel bone graft material for sinus bone graft.

Influences of Unilateral Mandibular Block Anesthesia on Motor Speech Abilities (편측 하악전달마취가 운동구어능력에 미치는 영향)

  • Yang, Seung-Jae;Seo, In-Hyo;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2006
  • There exist patients complaining speech problem due to dysesthesia or anesthesia following dental surgical procedure accompanied by local anesthesia in clinical setting. However, it is not clear whether sensory problems in orofacial region may have an influence on motor speech abilities. The purpose of this study was to investigate whether transitory sensory impairment of mandibular nerve by local anesthesia may influence on the motor speech abilities and thus to evaluate possibility of distorted motor speech abilities due to dysesthesia of mandibular nerve. The subjects in this study consisted of 7 men and 3 women, whose right inferior alveolar nerve, lingual nerve and long buccal nerve was anesthetized by 1.8 mL lidocaine containing 1:100,000 epinephrine. All the subjects were instructed to self estimate degree of anesthesia on the affected region and speech discomfort with VAS before anesthesia, 30 seconds, 30, 60, 90, 120 and 150 minutes after anesthesia. In order to evaluate speech problems objectively, the words and sentences suggested to be read for testing speech speed, diadochokinetic rate, intonation, tremor and articulation were recorded according to the time and evaluated using a Computerized Speech $Lab^{(R)}$. Articulation was evaluated by a speech language clinician. The results of this study indicated that subjective discomfort of speech and depth of anesthesia was increased with time until 60 minutes after anesthesia and then decreased. Degree of subjective speech discomfort was correlated with depth of anesthesia self estimated by each subject. On the while, there was no significant difference in objective assessment item including speech speed, diadochokinetic rate, intonation and tremor. There was no change in articulation related with anesthesia. Based on the results of this study, it is not thought that sensory impairment of unilateral mandibular nerve deteriorates motor speech abilities in spite of individual's complaint of speech discomfort.

Analysis of relationship between cracked tooth syndrome and occlusion using Q-ray and T-scan (큐레이(Q-ray)와 티스캔(T-scan)을 사용한 치아균열증후군(cracked tooth syndrome)과 교합 사이의 상관관계에 대한 분석)

  • Ahn, Do-Gwan;Choi, Jin-Woo;Kim, Yuseong;Pyo, Se-Wook;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.271-280
    • /
    • 2021
  • Purpose. The aim of this study was to evaluate the relationship between the patient's occlusion and a cracked tooth by using T-scan occlusal analysis and a quantitative light-induced fluorescence (QLF) technology. Materials and methods. This study was carried out on 51 patients having cracked teeth between January, 2019 and December, 2020. The tooth crack was determined with a Q-ray pen and QLF parameters (ΔFmax and ΔRmax) were obtained by a Q-ray software. T-scan tests were conducted to all subjects and then, the occlusal force and disclosing time were analyzed. Mann-Whitney U test was performed to compare the occlusal force and disclosing time between cracked teeth groups and contra-lateral normal teeth groups (α = .05). Mann-Whitney U test was performed to compare ΔFmax and ΔRmax according to the results of cold/bite tests (α = .05). A Spearman correlation analysis was run to determine the relationship between ΔFmax or ΔRmax and occlusal force or disclosing time (α=.05). Results. The mean occlusal force and disclosing time were significantly higher on cracked teeth than on normal teeth (P < .05). The ΔFmax or ΔRmax were not significantly different according to the results of cold/bite tests (P > .05). There was no correlation between ΔFmax or ΔRmax and occlusal force or disclosing time (P > .05). Conclusion. There was a significant relationship between occlusion and cracked tooth syndrome. QLF has the potential to be a valuable tool for the diagnosis of tooth crack in clinical practice.

Identification of Mesiodens Using Machine Learning Application in Panoramic Images (기계 학습 어플리케이션을 활용한 파노라마 영상에서의 정중 과잉치 식별)

  • Seung, Jaegook;Kim, Jaegon;Yang, Yeonmi;Lim, Hyungbin;Le, Van Nhat Thang;Lee, Daewoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.221-228
    • /
    • 2021
  • The aim of this study was to evaluate the use of easily accessible machine learning application to identify mesiodens, and to compare the ability to identify mesiodens between trained model and human. A total of 1604 panoramic images (805 images with mesiodens, 799 images without mesiodens) of patients aged 5 - 7 years were used for this study. The model used for machine learning was Google's teachable machine. Data set 1 was used to train model and to verify the model. Data set 2 was used to compare the ability between the learning model and human group. As a result of data set 1, the average accuracy of the model was 0.82. After testing data set 2, the accuracy of the model was 0.78. From the resident group and the student group, the accuracy was 0.82, 0.69. This study developed a model for identifying mesiodens using panoramic radiographs of children in primary and early mixed dentition. The classification accuracy of the model was lower than that of the resident group. However, the classification accuracy (0.78) was higher than that of dental students (0.69), so it could be used to assist the diagnosis of mesiodens for non-expert students or general dentists.