• 제목/요약/키워드: Dental Laboratory Technology

검색결과 689건 처리시간 0.027초

중·고생의 치아우식증과 구강건강행태와의 관련성 연구: 제9차(2013년) 청소년 건강행태 온라인 조사 (Relationship between dental caries and oral health behavior in middle and high school students: The Ninth(2013) Korean Youth Risk Behavior Web-based Survey)

  • 이종화;백지민;유지영
    • 한국치위생학회지
    • /
    • 제15권1호
    • /
    • pp.119-127
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the relationship between dental caries and oral health behaviors in middle and high school students by web-based survey of the ninth(2013) Korean youth risk behavior. Methods: The subjects were 75,149 students from 400 middle schools and 400 high schools. Finally, the survey participation rate was 96.4%(72,435 students from 799 schools) by complex sample design. The questionnaire consisted of general characteristics of the subjects, oral health behaviors, and oral health status. General characteristics included gender, types of schools, economic condition, and residential types. Oral health behaviors included subjective oral health condition, frequency of tooth brushing, tooth brushing after meal within recent 7 days, sealant within 12 months, fluoride application within 12 months, scaling within 12 months, and oral health education experience within 12 months. Oral health condition included dental caries incidence within 12 months. Results: Oral health behavior influenced on dental caries in the middle and high school students in Korea. This study showed the relationship between the sociodemographic characteristics, tooth brushing frequency, sealant experience, dental caries and halitosis experience, and scaling within 12 months. Scaling is the best prevention method for dental caries and halitosis in the students. Conclusions: The study showed the necessity for practical oral health education and the effect of fluoride application for dental caries prevention.

Nicotinamide phosphoribosyltransferase regulates the cell differentiation and mineralization in cultured odontoblasts

  • Kang, Kyeong-Rok;Kim, Jae-Sung;Seo, Jeong-Yeon;Lim, HyangI;Kim, Tae-Hyeon;Yu, Sun-Kyoung;Kim, Heung-Joong;Kim, Chun Sung;Chun, Hong Sung;Park, Joo-Cheol;Kim, Do Kyung
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제26권1호
    • /
    • pp.37-45
    • /
    • 2022
  • The aim of the present study was to investigate the physiological role of nicotinamide phosphoribosyltransferase (NAMPT) associated with odontogenic differentiation during tooth development in mice. Mouse dental papilla cell-23 (MDPC-23) cells cultured in differentiation media were stimulated with the specific NAMPT inhibitor, FK866, and Visfatin (NAMPT) for up to 10 days. The cells were evaluated after 0, 4, 7, and 10 days. Cell viability was measured using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. The mineralization assay was performed by staining MDPC-23 cells with Alizarin Red S solution. After cultivation, MDPC-23 cells were harvested for quantitative PCR or Western blotting. Analysis of variance was performed using StatView 5.0 software (SAS Institute Inc., Cary, NC, USA). Statistical significance was set at p < 0.05. The expression of NAMPT increased during the differentiation of murine odontoblast-like MDPC-23 cells. Furthermore, the up-regulation of NAMPT promoted odontogenic differentiation and accelerated mineralization through an increase in representative odontoblastic biomarkers, such as dentin sialophosphoprotein, dentin matrix protein-1, and alkaline phosphatase in MDPC-23 cells. However, treatment of the cells with the NAMPT inhibitor, FK866, attenuated odontogenic differentiation, as evidenced by the suppression of odontoblastic biomarkers. These data indicate that NAMPT regulated odontoblastic differentiation through the regulation of odontoblastic biomarkers. The increase in NAMPT expression in odontoblasts was closely related to the formation of the extracellular matrix and dentin via the Runx signaling pathway. Therefore, these data suggest that NAMPT is a critical regulator of odontoblast differentiation during tooth development.

The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resin

  • Su, Naichuan;Yue, Li;Liao, Yunmao;Liu, Wenjia;Zhang, Hai;Li, Xin;Wang, Hang;Shen, Jiefei
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.214-223
    • /
    • 2015
  • PURPOSE. To measure the surface loss of dental restorative zirconia and the short-term bond strength between an indirect composite resin (ICR) and zirconia ceramic after various sandblasting processes. MATERIALS AND METHODS. Three hundred zirconia bars were randomly divided into 25 groups according to the type of sandblasting performed with pressures of 0.1, 0.2, 0.4 and 0.6 MPa, sandblasting times of 7, 14 and 21 seconds, and alumina powder sizes of 50 and $110{\mu}m$. The control group did not receive sandblasting. The volume loss and height loss on zirconia surface after sandblasting and the shear bond strength (SBS) between the sandblasted zirconia and ICR after 24-h immersion were measured for each group using multivariate analysis of variance (ANOVA) and Least Significance Difference (LSD) test (${\alpha}$=.05). After sandblasting, the failure modes of the ICR/zirconia surfaces were observed using scanning electron microscopy. RESULTS. The volume loss and height loss were increased with higher sandblasting pressure and longer sandblasting treatment, but they decreased with larger powder size. SBS was significantly increased by increasing the sandblasting time from 7 seconds to 14 seconds and from 14 seconds to 21 seconds, as well as increasing the size of alumina powder from $50{\mu}m$ to $110{\mu}m$. SBS was significantly increased from 0.1 MPa to 0.2 MPa according to the size of alumina powder. However, the SBSs were not significantly different with the sandblasting pressure of 0.2, 0.4 and 0.6 MPa. The possibilities of the combination of both adhesive failure and cohesive failure within the ICR were higher with the increases in bonding strength. CONCLUSION. Based on the findings of this study, sandblasting with alumina particles at 0.2 MPa, 21 seconds and the powder size of $110{\mu}m$ is recommended for dental applications to improve the bonding between zirconia core and ICR.

2 Key Bridge에 대한 연구 (A Study on the 2 Key Bridge)

  • 박종희
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.57-67
    • /
    • 2000
  • The 2 key bridge system has been developed to make crownless bridges without damaging sound teeth. Strong bridge work of single or multiple pontics is possible for replacing both anterior and posterior teeth. It is incresingly considerde to be unacceptable, by dentists as well as patients, to fully grind down healthy elements in order fit a conventional bridges. Because this technique uses a combination of hole and adhesive fitting, it has a number of adventages over etched bridges and conventional bridges: - In comparison with conventional bridges, hardly and healthy dental tissue is sacrificed - Due to the lack of crown edges there is no periodontal pressure, as is the case with conventional bridges - The treatment procedure is straight forward and involves less time than conventional bridges. - The treatment is largely resiverable and repairable

  • PDF

지르코니아 CAD/CAM block의 강도에 관한 연구 (A study on the Flexural strength of zirconia CAD/CAM block)

  • 이정수
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.65-69
    • /
    • 2008
  • Recently, zirconia is widely used in the field of dental ceramics thanks to the proliferation of CAD/CAM systems. Accordingly, different types of zirconia block are being solid in the market. However, there are no precise, objective standards for properties of zirconia. This study concerns the flexural strength of zirconia ceramic for CAD/CAM block. The test specimens used for this study were ZirBlank(Acucera), ZirBlank shade(Acucera), VITA, Cercon(Densply) and Cerasys. The test results suggest that ZirBlank shade block shows the highest flexural strength and density among the zirconia blocks tested. Its flexural strength was $971{\pm}58MPa$ and its density was 99.89%. On the other hand, Cerasys block shows the lowest flexural strength of $576{\pm}36MPa$ and the lowest density of 94.85%. Given all, the density of the specimens is found to be directly proportional to strength and inversely to grain size.

  • PDF

레진치아의 표면처리가 의치상과의 결합강도에 미치는 영향 (Effect of Facial Treatment for Resin Teeth on Bonding Strength of Denture)

  • 김용원
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.71-77
    • /
    • 2008
  • Acrylic resin has been widely used for dental care since it requires relatively simple equipment for treatment and less time and cost are needed to make it and, furthermore, proper strength, dimensional stability as well as durability are ensured after treatment. A survey of denture users showed, however, that more than 60% of dentures installed need repair each year, $22{\sim}30%$ of which are due to falling out of teeth. This study is aimed at exploring the means to increase bonding strength of denture by reducing the causes for falling out of teeth during the processing of dentures. For this aim, the bonding strength of dentures was compares and analyzed before and after the glazed surface of teeth contacting denture was eliminated. From the analysis, it was revealed that there was a difference of 4.3MPa in average in bonding strength between 20MPa for the glazed surface not eliminated and 24.3MPa for the glazed surface eliminated.

  • PDF

고령 환자의 기존 의치를 치과기공소에서 수리한 증례 (Denture repair for elderly patients in dental laboratories: a case report)

  • 이주형;이규헌
    • 대한치과기공학회지
    • /
    • 제44권4호
    • /
    • pp.154-160
    • /
    • 2022
  • The need for repairing removable dentures has grown as the population had aged. The direct methods allow existing dentures to be repaired without interrupting their use. However, if patient compliance is low, direct methods may be challenging. Moreover, attaching an artificial tooth to a metal base is a complicated procedure because it necessitates casting a retentive element and soldering it to a metal base. This clinical report describes how to add an artificial tooth to a metal base, reline denture bases, and reestablish occlusion on relined removable dentures using indirect methods. Existing removable dentures were successfully repaired and their service life was efficiently extended using the methods described.

코로나 19로 인한 온라인 수업에서 시간적 기대 효익, 학습효과 기대 효익, 기술적 친숙도가 수업만족도에 미치는 영향 (In COVID-19, the Effect of Expected benefit of Time, Expected benefit of Learning, and Technology Familiarity in Online Class on Class Satisfaction)

  • 유상희
    • 한국융합학회논문지
    • /
    • 제12권11호
    • /
    • pp.257-263
    • /
    • 2021
  • 본 연구는 온라인 수업만족도에 영향을 미치는 요인을 분석하여 비대면 수업을 보다 효과적으로 운영하기 위한 기초자료로 활용하고자 하였다. 설문 조사는 전북과 충북에 소재한 치기공과 재학생의 208부 설문지를 분석하였다. SPSS 프로그램을 이용하여 신뢰도 분석, 기술적 통계, 평균분석(t-test, one-way ANOVA), Pearson의 상관분석, 단계적 다중회귀분석을 시행하였다. 분석결과 연구대상자의 시간적 기대 효익은 3.87, 학습효과 기대 효익은 3.30, 기술 친숙도는 3.40, 수업만족도는 3.21로 나타났다. 수업만족도에 가장 큰 영향을 미치는 요인은 기술적 친숙도이었다. 온라인 수업만족도를 높이기 위하여 수업에 활용되는 학습 도구의 활용능력과 온라인 수업 시스템에 대한 기술적 친숙도를 향상시키기 위한 학습환경을 구축해야 할 것이다.

코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가 (Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy)

  • 김재홍;김원수;김기백
    • 한국치위생학회지
    • /
    • 제13권2호
    • /
    • pp.361-368
    • /
    • 2013
  • Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.